DESIGN OF HOT BLAST STOVES 317 TABLE 5—Continued COMBUSTION OF BLAST FURNACE GAS—COMPUTATION SHEET 2 Points for heat capacity curves. Products of combustion, air and gas volumes from Appendix X are multiplied by values in Table 8, Appendix X. Vol. 200° 400° 600° 800° 1000° 1200° 1400° 1600° 1800° N2 111.33 CO2 36.91 H20 5.57 155 68 10 314 147 20 480 238 33 048 445 46 827 458 61 1008 574 77 1195 708 95 1386 853 113 1582 1004 133 2 100% air 233 481 751 1139 1346 1659 199S 2352 2719 +20% 13.55 19 38 58 79 101 123 145 169 193 S 120% air 252 519 809 1218 1447 1782 2143 2521 2912 C+40%27.10 38 76 116 158 202 246 290 338 386 S 140% air 271 557 867 1297 1548 1905 2288 2690 3105 H-80% 54.20 76 152 032 316 404 492 580 676 772 2 180% air 300 633 983 1455 1750 2151 2578 3028 3491 Pleat Capacity Air Supply 100% 67.75 94 191 292 394 120% 81.30 113 229 350 473 140% 94.85 132 267 409 552 180% 121.95 170 344 526 710 Heat Capacity of the Gas N2+ 85.39 117 238 364 491 CO2 12.96 24 52 83 118 H20 1.65 3 6 9 13 S ..... 144 296 456 622 N2 57.13+02 0.39+H2 3.92+CO 23.95 = 85.39