Skip to main content

Full text of "The Flow Of Gases In Furnaces"

See other formats


298

APPENDIX VII

TABLE 20—Continued

Temperature,
			Volume of Waste Gas,
			Heat Available,
		
Degrees F.
			Cubic Feet per Second
			B.t.u. per Second
		
Initial
	Final
	Drop
	Initial
	Final
	Change
	Initial
	Final
	in Boiler

1652
	752
	900
	1939
	1114
	825
	17,206
	7326
	9,880


	662
	990
	
	1028
	911
	
	6337
	10,869


	572
	1080
	
	947
	992
	
	5488
	11,718


	482
	1170
	
	866
	1073
	
	5450
	12,666

1472
	752
	720
	1777
	1114
	663
	15,134
	7326
	7,808


	662
	810
	
	1028
	749
	
	6337
	8,797


	572
	900
	
	947
	830
	
	5488
	9,646


	482
	990
	
	866
	911
	
	4540
	10,594

1292
	752
	540
	1610
	1114
	496
	13,492
	7326
	6,166


	662
	630
	
	1028
	582
	
	6337
	7,155


	572
	720
	
	947
	663
	
	5488
	8,004


	482
	810
	
	866
	744
	
	4540
	8,952

1112
	752
	360
	1443
	1114
	329
	11,168
	7326
	3,842


	662
	450
	
	1028
	415
	
	6337
	4,831


	572
	540
	
	947
	496
	
	5448
	5,680


	482
	630
	
	866
	577
	
	4540
	6,628