DESIGN OF HOT-BLAST STOVES
313
TABLE 4
DATA ABSTRACTED FROM "BLAST FURNACE ADVANCEMENT/' BY A. E.
MACCOUN, PRESENTED BEFORE THE AMERICAN IRON AND STEEL INSTI-
TUTE MEETING OP MAY 28, 1915
Test of a 22' 0"X 100' 0"Two-pass Cowper Hot-blast Stove
Heatin0* surface of checkers .
51 192 ft2
4764 m2
Total of stove ...........
55 866 ft2
5202 m2
Combustion chamber, area .......... . . . .
40 8 ft2
3 m2 79
Height to burner ..........................
10 62 ft
3 m 50
Above burner ............................
76 75 ft
23 m 10
Total ....
87 38 ft
26 m 60
Volume, below burner ...
468 ft3
13 m3 26
Above burner .............. . .
3092 ft3
87 m3 54
Total .........................
3560 ft3
100 m3 80
Dome volume
1381 ft3
39 m3 10
Checker Number of passes
329
Dimensions of passes. ...
6"X6"
150X 150 mm
Total area of passes .........
82 25 ft2
7 m2 64
Perimeter of one pass ....................
2 0 ft
0 m 60
329 passes
658 ft
197 m 40
Height of .....
77 75 ft
24 m 00
Heating surface = 197 . 40X 24 . 0 = .............
51.160 ft2
4738 m2
(Difference due to use of approximate metric value)
Wall thickness ................................
0 25 ft
75 mm
Area per pass = (150X75)2 =
0 m2 050625
Of pass = 1502.
0 m2 02250
Brickwork per pass (difference) . . ......
0 m2 028125
Percentage of in brick (Table 3) .............
55 56
In pass (Table 3)
44 44
Total Checker = 0 050625X329 =
16 m2 655
Passes = 0 . 022500X329 = .............
7 m2 403
(Difference due to use of approximate metric value?)
Brick = 16 655-7.403= ................
9 m2 252
Volume, Total brick and passes 16.655X24= .....
400 m3 30
Passes = 7 403X24 =
177 m3 64
Brick ......................................
222 m3 66
(Difference due to use of approximate metric value)
Weight (as given) 251.85X1800 =.
(metric) 222.66 X1800 = .
453,350 kg
400,800 kg