DESIGN OF HOT BLAST STOVES

317

TABLE 5—Continued
COMBUSTION OF BLAST FURNACE GAS—COMPUTATION SHEET 2

Points for heat capacity curves.    Products of combustion, air and gas
volumes from Appendix X are multiplied by values in Table 8, Appendix X.

Vol.
	200°
	400°
	600°
	800°
	1000°
	1200°
	1400°
	1600°
	1800°

N2  111.33 CO2 36.91 H20  5.57
	155 68 10
	314
 147 20
	480 238 33
	048 445 46
	827 458 61
	1008
 574 77
	1195
 708 95
	1386 853 113
	1582 1004 133

2 100% air
	233
	481
	751
	1139
	1346
	1659
	199S
	2352
	2719

+20% 13.55
	19
	38
	58
	79
	101
	123
	145
	169
	193

S 120% air
	252
	519
	809
	1218
	1447
	1782
	2143
	2521
	2912

C+40%27.10
	38
	76
	116
	158
	202
	246
	290
	338
	386

S 140% air
	271
	557
	867
	1297
	1548
	1905
	2288
	2690
	3105

H-80% 54.20
	76
	152
	032
	316
	404
	492
	580
	676
	772

2 180% air
	300
	633
	983
	1455
	1750
	2151
	2578
	3028
	3491

Pleat Capacity Air Supply

100% 67.75
	94
	191
	292
	394

120% 81.30
	113
	229
	350
	473

140% 94.85
	132
	267
	409
	552

180% 121.95
	170
	344
	526
	710

Heat Capacity of the Gas

N2+     85.39
	117
	238
	364
	491

CO2      12.96
	24
	52
	83
	118

H20        1.65
	3
	6
	9
	13

S        .....
	144
	296
	456
	622

N2 57.13+02 0.39+H2 3.92+CO 23.95 = 85.39