APPENDIX X

TABLE 2

VOLUMETRIC Am SUPPLY AND VOLUME OP PKODUCTS OF COMBUSTION PER
100 VOLUMES OF GAS BURNED.    COMPUTED FROM DATA IN TABLE 1

Per Cent
 (1)
	Air Supply
		Products of Combustion per Unit Volume of Gas Burned
							
	Vols. (2)
	Excess Vols. (3)
	Excess 02 (4)
	CO
 (5)
	H2
 (6)
	C02
 (7)
	H20
 (8)
	Excess
 N2 (9)
	Total N2 .(10)
	Total Vols. (11)

60 80 100 120 140 180 260 340 420 500
	98.51 131.40 164.25 197.10 229.95 295.65 427.05 558.45 689.85 821.25
	-65.70 -32.85 0.0 +32.85 65.70 131.40 262.80 394.20 525.60 657.00
	-13.14 - 6.57 0.0 + 6.57 13.14 26.28 52.56 78.84 105.12 131.40
	20.76 10.38
	5.52 2.76
	15.74 26.12 36.50 36.50 36.50 36.50 36.50 36.50 36.50 36.50
	22.68 25.34 28.20 28.20 28.20 28.20 28.20 28.20 28.20 28.20
	
	125.14 151.42 177.70 203.98 230.26 282.82 387.94 493.06 598.18 703.30
	189.84 216.02 242.40 275.25 308.10 373.80 505.20 636.60 768.00 899.40

								
		
								0.0 26.28 52.56 105.12 210.24 315.36 420.48 525.60