£3; rigiaee aha Syst : Aes ee ees oe Ag 4 sy : : Kye ee Be Sete 4 - poe at ~ G . = ire Sekar oe : = A = s. ees 5 n: a Fae See Pippa P 40 AZ J , 1 k 5 Cre akties BT, - y re eS ER Se, d i> Some nd roe = ape? > 5 Pe F PEN nF eas bear ne ; : 5 est bP At Wr et Return this book on or before the Latest Date stamped below. University of Illinois Library J ith} ber iIDU | | 5) SEP 2 3 1975 Ta i= SEP 41 11975 Se Se © L1o1—Ii41 Digitized by the Internet Archive in 2011 with funding from University of Illinois Urbana-Champaign http://www.archive.org/details/indexsummaryoftneOOredd THOS. J. HEAVEY GENERAL CONTRACTOR 20 N. Wacker Drive, Civic Opera Building CHICAGO Construction : Remodeling . Fire Appraisals Phones Residence Phone State 6674 - 6675 Longbeach 4323 G. EARL GRINDLE, INC. REALTORS: REAL ESTATE MANAGEMENT REAL ESTATE SALES BUILDERS OF (2%) BUILDING GUARANTEED Brcsron PROJECTS HOMES ey FINANCED INSURANCE 5693 LINCOLN AVENUE LONG BEACH 7100 CHICAGO, ILLINOIS CARL E. ERICKSON & CO., INC. 2847 N. Clark St. Lake View 4041 CHICAGO GENERAL CONTRACTORS AND BUILDERS STRUCTURAL STEEL FABRICATORS Buildings - Bridges - Industrial Plants - Machinery Bases Air Locks + Contractors’ Equipment Galvanized Steel for Substations & Towers MISSISSIPPI VALLEY STRUCTURAL STEEL.CO. CHICAGO PLANT OTHER PLANTS MELROSE PARK, ILL. ST. LOUIS, MO. CHGO. PHONE - MANSFIELD 2120 DECATUR, ILL. CHICAGO INSULCRETE COMPANY Manufacturers WAYLITE INSULATING BLOCKS BLOCKS using WAYLITE Superior Lightweight Aggregates for All Types of Buildings RECENT LARGE INSTALLATIONS HOYNE-GRANVILLE APARTMENTS CHICAGO WOLCOTT APARTMENTS CHICAGO ISABELLA PARK APARTMENTS EVANSTON FRANKLIN PARK, ILLINOIS Phone Enterprise 2277 INDEX SUMMARY of the New GCarcAGO BUILDING CODE Mae COMPLETE CROSS REFERENCES ad © Compiled by EDAD EE. REDDERS EN Architect ILLINOIS - MINNESOTA - WISCONSIN Structural Engineer ILLINOIS Plan Examiner DEPARTMENT OF BUILDINGS, CITY OF CHICAGO SINCE 1914 CopyRIGHT 1939 BY Epwarp E. REDDERSEN ke. FOREWORD No member of the Department of Buildings of the City of Chicago, and no member of any other department of the City of Chicago has had any hand, directly or indirectly, in the compilation of this Index Summary. No part of this Index, therefore, can be considered in any sense as any official wording or interpretation of the Building Code. Such wording or interpretation as contained in the Index is solely the responsibility of the author. His experience as Plan Examiner, Department of Buildings, City of Chicago; since 1914, has fitted him to know the needs of architects, engineers, and builders, and it is believed, to satisfy those needs with the first adequate index of any Chicago Build- ing Code. Since it is inevitable that errors and ambiguities should creep into this tremendously detailed work, the author will appreciate any notice of such errors or discrepancies. It should be noticed, however, that many apparent errors are due to conflicts in the code itself and not to the Index. This Index Summary does not include:— The Electrical Code The Fire Prevention Code Chapter 83 Water Supply and Distribution Systems Chapter 84 Steam Boilers and Unfired Pressure Vessels Chapter 85 Mechanical Refrigeration The Zoning Ordinance WAYLITE-SUPEROCK THE MODERN BUILDING MATERIAL WITH Light-Weight Concrete Aggregates INSULATING BACK-UP BLOCKS with Highest Fire Resistance Highest Insulation Value of any Lightweight Aggregate Highest Acoustical Value for Interior Exposed Walls Whitest Exposed Inside Wall 40% lower cost than Brick as a Back-up Material Easily N eee Can be Nailable saint ear Sawed and Cut Strips SUPERIOR CONSTRUCTION PLUS ECONOMY THE WAYLITE COMPANY 105 WEST MADISON STREET CHICAGO, ILL. TELEPHONE STATE 4336 PN DEX TOM REVE DIN DEX” SUMMARY (GeO, JER IDIDS oa ee i Beet ane ee te er re This covers all general and miscellaneous items on buildings and structures of all kinds. It should be referred to first if the class of use or type of building is not known, or if it is uncertain in what chapter the item under consideration properly belongs. OccuPpANCY CHAPTERS INDEX SUMMARIES: These include complete detailed indexes of the individual chapters men- tioned below. Each is a specialized index for a particular class or group of related occupancies and should be used for design purposes. Such chapters can be used as a “‘check list”’ to insure that all Code requirements of a specialized character are complied with. CHAPTERS 47 SII PAe PID VEL IM a pas wise ater ceccss fee as 8 cle bslose uh amet yee ecco 48 MULE eM iW ClITI CS. sy settee ec cout Rosie wis to socne- cused eacse atten Oe 49 iSereutonalebUildings.:.. 200. i WEA S oaks ones egies toes ah voraees 50 I ISPMES GMO MME rnc ferark wees cet tea a. aera ae egeed Meegho nes ae Si MazandOuseUSesUMIES:. 4. 2h cide de ak, Gs Sein eee Dee 52 EAD CS et fears yore nis. ore, 2 NS yma Momeni Pep cata ores he ee 53 MCR ERCSwe teres Ae Kc St ae i.e De otis ee: oo aA ee J 54 OpeneAir sAcsem bly MWMIt |< cae eoe ese ate oc sw directness 58) Bubp niee Assen ly an Wmits, tee Alen einai as crcires ahaa iste s eect 56 (CLs eo) aetna a Cee cee cee ee ME RUE ES oo ct Sok OM SCHOO Sheet ears Se ee a ee ease he eames eis SER 58 Other Buildinesrand Structures. «acs. 2 sete ame ae eee MISCELLANEOUS CHAPTER INDEX SUMMARIES CHAPTER 79. Elevators, Dumbwaiters, Escalators, and Mechanical Amusement WOeVices:. fois. oractaistess. scsueee ocen uye tore: bos SE aene Sree Re Sle LE MING... v., atyce-eac eels rote oso a ies aso aUnAlecaaale eras TABLES :-— ET eMEOOMCONSERICLLOD.<\- coarse aaa. oR Coe Me Ee eNOS SUMO Me DTOON CONSERUCLI OMe mi wen a aen kate cpaleels tic ne cio witcher Bobs, BO evccas Reawallin ber CONStTUCHOME 2.1.2... UNctih ce stuitieie a ces Se ee welele sce WreinahvaGOuStrUction..... Adis, nn Waren onsen: S08 wa A deleiatacinm shes Mareen NMOGUMBONSERUGEIONS « nis.cmmere Bore swans oo kbs aon oan. waetv an were Fire Resistive Construction: Hour ratings :— Blaorsootswand: Celimpsc ds nce weet ss eare atom) |p witiec kek bry oe Sis Protective, Coverings of Metal Membets:..c. 2.20.22... 8.0.00. .00 0s RN McelkseaTiG@ Ur eltlolS:..5 . Wena caster i edith ahah fos Syentt h: Sk Siew ay train sacar ots INTO MERI CATE GHAR TER OLNID hXcy. meena ene We ein a ivencts lw sitlest mie Glese ¢ KUEHL & HEAVEY Engineering Consultants STRUCTURAL ENGINEERS LAND SURVEYORS RECORDED SOUND AND VIBRATION ANALYSIS Engineering data supplied and computations made for Attorneys Contractors Public Utilities Building Owners Real Estate Agents Insurance Companies sara oes 9873 20 N. WACKER DRIVE, CHICAGO Permanent BLUE PRINTS Blue Printing, Black Printing, Blue Line and Color Printing Blue Print Paper Drawing Materials Special Service Always — Speed and Results Big Floor Space and Equipment for Rush Orders Photo Prints CROFOOT, NIELSEN & CO. BRANCHES ENGINEERING BLDG. 307 N. Michigan Ave. 205 Wacker Drive 80 E. Jackson Blvd. Tel. Randolph 3341 EDWARD J. BAHE COMPANY, INC. Wholesale Manufacturers of QUALITY QUALITY DOOR FRAMES WINDOW FRAMES KILN DRIED LUMBER EXCLUSIVELY 2336-50 NELSON STREET Lakeview 0360-1-2 CHICAGO 7 ie . : > } ‘4 a 7 "r — | -o a a J y Yee) A 4, a ; — soy? | ' _ GENERAL INDEX \ \Y GENERALE INDEX Mogmienis, GIGI. coleossono.g Gano Gobo n Cee RRO Monee ae. Sere aa. ee Acoustic Materials :— Attachment: Combustible material :— By cement or other non-combustible material...................... To: 1. Heavy Timber Construction (nailed)........ 61-57 de VMetallathvandsplaster.cellinge jo c-sncee sects. ce ses sas es SP NOn-combpustiblesurmaceuneare ass cciacmewGn as sas oes cctor Attachment: Non-combustible material:— JERrS CISNGINGE 5 et ora bro. clond BOD 6-0, COTE OCC cna et eae eee ee iINails——Heavyebimber Construction’. «24 o2eacs.. cscs sees ecrns Non-combustible fummnoistripsss.smeacao seco ses cet oss doen. - Ceilings: Acoustic material to be non-combustible :— IPAVVATETIRCE TMM OMS HUET ce at si yciset ie aie asus oer suaGTeNy cs ais So snane, crate winielscdis PRAWihengcellingsis suspendeder emcees a oc0 + ce eme seo oo see sts ans ac Sea Penacellingaisimon=required qart.cs sc cys. sacs es. eee oes ec Ceilings: Supports must be non-combustible :— il, \Wingin Gailbtne ie shatsG le oie os Seba 8 OGRE e One o De Ono aan omae PmaViitentceilingrisisuspendeda ys -c0.ccensse sects it eos te bees Smaitenscellingsis Mon-required = 4... oats ols ogee ee sr es elo aa Dernedsasisoundabsorbingmaterial > 5.0.5.5 ...as ese ess sce en aee Mestinemahoratonys tocertiiy LEStS|: seas ccsee ae eran acse ss «sqaure - Mestsrcorquality, as mon-combustibless.. ...-2..eeeee-4- sane neces Aglohitiom, GMMEGI Ss 5 5 ooo 4 oe .crOd o cre Se are ence tei ieee te eee Aisle:— iLammentnenaliinell. aks tial cgi aed Gro OI ee MICO ERE oe Clare eae eee ey ote MBG ATAS VE TSe MEG CLIN Oempen tran it poe noice fence cde ciel chevagah a qtay © tks neyniese See also Occupancy Chapters 47-58 Index Summary Nears, GOING 5 5° 4a. cio GIR On Meo RENE RE eR NC ea Poy pw) CLIC G PMPp ress aer areas do eg oe sie ane saree bv cvsuv gf fisdeue wisianaue Ham eee Mes Clearance for fire escapes:— Ceneraleplasttclearstovanyepatts. o.o.: 06 noose ce so esse ce ye eevee oe Theatres :— Nooe@ alleys Gate > 6 ou a Romeo Ore D Con oor cee tee PNDOVEISIGE Wale Dt Pye ten. sicily cies 316 Wyensircleiiovel sud e: sieie oie bu Aisle sree ods ons ANiicraiion, Caines. 6 oe oine aa oo ice Rees Tee Oc ae core oe Se ane ATMO AtoOmes denned aSspromenades a. «240.2. a5 4 ace oe ver eeemio nesses American Concrete Institute, Standards:— Building Regulations for Reinforced Concrete A.C.I. 501-36T. February TS, DE so ef cespek cerecd 6G o: Goers et On are nee en nena aT American Society for Testing Materials, Standards:— Bitckeq@layzis pec. | G-O2-30n emasj aes ne class cecian es 6 68-4 (ONCKELOs C9934 Seo crys een PA MONO sharin Fim ear oes ows 68-4 Sancdelimem 2713-3 0)-e eee aN cee e-neie cl nirore Soe 68-4 Shalem 262 =30)c/5: 00 see eee ieee hisideenins tata 68-4 Caste, Tigoyal,- Ja 1Ss Oe eee ci ors. canicicsie cncta tora icaeh Ser Mean Nie cro Serrated Al nee Case, Siiciaie SISSY EES eas Bikes ese do rN Conte ens en ree Gement-eMasonry ©-91e32e0 oye sencwet toe oie re) hele ss ss, osu Galen custo oes Portland, high early strength, C-74-36.............. 73-14 Ronilandmereg ular’ G-923 175 mrt aero eyy crete see dlees eo tcreyel 5-9 clave Sypienie cis heater a eaten yam are oie atest ey ae 73-50 Fastened. below center on side at end... .c.5 6 ccc ie eee sole eto dee 73-50 Fastened on top-of parallel joists: .cc...g.420005s0h<05s she dda eet een 73-50 Fastened to include 53 in. of parallel joists...................00-005- 73-50 Size; Ares; mim. O14 Sq. Wa hea ant eia eh tates ein eee ame 73-50 (Mhickness, win: seo t eaecie cena a8 So ors gras sais eee eeiee 73-50 Splice plates, abutting members... .. 22.624 ans00. pies oe ee curenan 73-50 Annexes :— Public-assemibly Unitvsede. cee sees eee Ate eee ete ee 20-13 61-51 SCHOO SMe Seo 5 ec AT ee 57-14 61-51 See Roof Annex Construction Annual Inspections :— Amusement parks and devices:— Buildings incor connected within. .402.- sae ee ee erro 46-9 Devices, except riding type: . 2c seca. chin «xe ce eeveere sie elerepserss eens 46-9 Fees, for buildings B5.00% tcc teane sca ee toe ers cr anes erase 46-9 Billboards and Signboards:— Fees: '50/sq. ft..or. less; $0:50). 2.2. ee os trae eee lei 46-23 SOisqeett: to: 37 atsq= it. Plc O0 vanes seis ern noe eer emery ree. oleae: 46-23 Additional, 375 sq. tt. or fraction $1.00). 2... sadeeee see see 46-23 ] D>. {23001 0} (0) 0: e ear inne tended nner c.f cho oO ap cle 46-23 CGEM SPA snk) gah sess aug veees bb mE Re eve eRe. BRE Seng OOO I Re 46-18 to 46-20 Notices of violations... tac ccc e erase ne Sein Sethe ae eer eee 40-19 46-21 Penalties’ 2.2.5.5, snavecs evga a shed anda Sa Sage Ree ee ee eee eee 46-24 Gl GENERAL INDEX Annual Inspections 5) Annual Inspections:—(Cont.) Business unit and dwelling in building 2 stories or less, exempt......... 46-2 Boilersssmelerand multipledwellangss <2 .5..0.2.2.264-4-cee so 5 oa. 46-6 1S ane er 2512 GASES PANS a ave re ee ec eee ar 46-30 TNBOS), «STO hoy ko) PAD OS fab cee ale ene 46-31 SSiL@O a@lol, store Cavan 610) Keb isco nc demas oko. cron cero re anaeaoer 46-31 (Cenuhcatcoicompliance nance acc cinaee cl oeciices se nace ces eiace sans) 46-3 (CIMUiENES, oo s'ciold Ges Goma COP OU BoB U OS OBIE D CECI Tr ea einer: Senn 46-2 (CRIMI 5 o Hoo Brora bie Shio a cie orote Balto nok oe eur atacand nearer ne ee mere 46-8 DisMlavgacentilicate mms cers sie acute stole sls sie G Wiise/rebs ous corse ics aiins ates 46-3 DiSMlavap lation mnie ticaie 5 cys cieeiss oleae snus eae eens Giese oe ela erae 46-4 Elevators :— Ceniiicatexolcompilancenm sca. ae sc cies ci eee ee lee oem ee aot G 46-3 46-12 Cenniticatestorbe;pOStedin. s.r aa cece e oe Nemec nots Fan sieyeueeernnese 46-3 46-12 Every six months:— ID eran OTA CARA oe oi eiete Hid chow Ona Gn acon ete ao MmnanienGee 46-11 WSCal aon Mee eso ci hates co paisieie nied Gite isicpuemecansi atirarauncyaba eos 46-11 Gonewlls 3 6 dle aGteNie ene ein meric ene etic oer tesaictand ele 46-11 (COVRG NOSE; Ge cin Gite te nar ieee OIIcae Cc eee en eset nckeicr era 46-11 JEXORTEL? 6. 0 & cl Boek US IO OTE RRS teen RS ence eres ne noe 46-11 SHDES o 0.0'o.0 0 CS Gat Oot Sit PORES Co RO a EROgE enti e, one ereD CRC 6 oir 46-11 ANI GUNES. 5'6.6 0 send idle ules Gta ES RoICO DOI tec acco rice ene elaic o's oF 46-11 eects General mrs or OO Mersey irr Aiciciesssewcen orave sais eaves eran eucicae cureoemrare 40-8 PAG HESTOSACIIMLATT NED" Our. tence mis mete 3 on) ovaiaetare cis vers fox cic) fiers Po.cPa lassie 46-8 Sieel quien, SSO ee. Satalae arta rc onics Mien aia eG apie cna erent e 46-8 Hilezalatoroperate alter stop Order... 6.0.0.0. oc tee ore se een eee tee 46-14 ROW CIM ORS LOPROPELA COM riya ia tinteiers oc sicvaietere 4 eta Pe eve ss deco 46-14 iepalrsemade |perore certificate assueds.... 2. 2 eee snes Boece ene ene 46-13 ATMs EM OGUE Vara rea edt) ain2 ict ie = eee) ae See aialaiene sated a) tel olemieleiwal.« 46-2 Fees for Buildings :— 5.00), ites JO 00 Sola 6 ain oro ctoieo ao ould oma ora acinomae acleciae oor 46-6 So100meachradditionall2>/000)sqe ft. onless.. .05...-2---5----+5--- - 46-06 Exemptions Charitable imstitutions...-.....-2.ses8-+e5s sesso 46-7 Hdticationalinstitutionsss «ye accue ons. fo ccm cele. ccc oe nese sac 46-7 NGM STOUSAITIS IEUIELOMS ey rerericicis s ners Sill tila el ceeke Sc gaeeeie ciel netoreyons 46-7 lama ali] epi Gali steels meets mice scree ercyaetee cis ctaccistee ecisie steno 46-37 to 46-39 Gas holders over 2,500 cubic ft:— Hemel OLOOR re steer cyte sista ee se aemicigs ei et eones mesures 46-43 IETS DEC ULOM Merci sepa siete arcte ne FeNe cies utes veselcy aaa (otrnleash euelsv ee eorsusuer sevens" 46-42 Grandstands:— PAmimValeln SpPECtLOML sees siete misters: cies eeietenencngje acieie- cee aiermteuams eQak 46-16 Bapacity,o O00 or less plOOO/fee mien 2 i yteycisie ties s,s eiertio a oramrels 46-17 eapaciiypover 5/000; S20 OOMeCe. tia ise pe 46-2 Miultiplerdwellings) 3:storiesvonlesse ai riasc cero itiers tors ie 46-2 Sincleidwellingsk i) ccs tbae remit ciate ses oh erect suerswnycekeeroony. 46-2 ANG beStosiCuncalnnsp OO) fee: ererrmenemy citer ors ei susrcrenei aire meiey evel dencreencers 46-8 Clon NES 5 as, Ae Boh Rens cenecmtenlonarc ors aed Siete cimverctcn tie: cette Mics (ty core Beier 46-2 OpenyairzassemblysunMits 4./0 sere ae cae rein scketethiorerae a1 arene eisnc = 46-2 ublicgassemb ly aunty ms cic issc eter eer ctcies ieee aetna tae a eval ens 46-2 SANGO G s.s.5 dsidicis chy RRO REE EEL CCG OIE aes Ook icket tS onsts Gene I ne icon 46-2 Gl 6 Annual Inspections—Areaways GENERAL INDEX Annual Inspections:—(Cont.) Required :—(Cont.) TERRES... «oe uiae knee on ie os oes use hare aisle Ge 46-2 AnG Others as TEMUZEM 55:5. bose & csgrate vine h nics ie Pe 46-2 Revolving doors:— General... 6.5: sau. Séaie.n scans fees SoA eee 46-34 Certificates fey saloets on 20 6h eidsapelas ono ie Oe ee 46-35 BES, $35.00 5 ods itn oe wets Gg ee eg he OES on eet ae nen 46-36 Riding devices outside parks:— : REqUITe oases 3 Ue a ccs, hehe Or ee Ae oe a ee eee 46-10 HOGS i. ssc epasarn Pegs tester atin tenes Mane OBS enon eee ee 43-30 otecl curtain, $5.00 Tee. so. 0, ss 2cih 2% oan omaiadans oak ee 46-8 Tanks, ‘Roof: ‘Over 250) gallons o..4......00%s 2.02 ace aes ae ce cee ee 46-44 Bees,.g0:00 generally: oon aides datec sven Puen a ee ene ee 46-45 PIXE P CHOW < dec cin Soe A Adres eed orden ots wysianus eee etatolt ia os Ae a ee 46-45 Thirty day notice to comply. casks ceseues eucoure ote sea See ee ee 46-5 Apartment Genned o< & 2 sand sys aceus eed oe ok Ree ee ee 40-1 See Chapter 48, Index Summary Apartment Hotels. © «swe nccaans eee oe Heated eae tee eee 40-4 Apartment House:— DDCGNEO.. 2 WtrBaads staaehaddsieceeccetbesenee Meats pees eee 40-1 Multiple: Dwelltipt 3.22% cesurecises 145 «50s, 2k ne oe eee 40-4 Appeal, within 5 days before suits ./34.2.he cca sue athe sone wees Cee 13-15 Aquarium :— PHI INOW 5, ic-10.2-ara nS orien slave Seiwa: wart 1 ns outs oe as as ce 55=3 MEISGUR se, 23s cerns ers ores sees a eas state oor sents tebe acre 29-3 Publemassembly Unity ta 05 one esas tek ae ers Deena teats eee 95-2 Arbitration :— PDE OI oe 5G ceyetere ss ia tine ie sachs eles d ETA AS ia ea eta cl ean ia at 13-15 Appoimtments by Commissioner. +: ici i .ach i wenn. sesacedecenee sale 13-16 (COSE 32 seats eis arate athe ree o a erate orev tegatana ese ea ec 13-16 Generali tce\e sure See cars qt our srs enare Pasta en ine oe eee ee 13-14 Oaths:to: be taken. 2 7 tic2c. shana os pee a aac nak aa aanaee ede 13-17 Standards, Registrations, Penalties.............. 0.0.0 cece cence eee 41-1 to 41-3 Arcades defined as Promenades, sq i2cc25.09. 2 s0eewe pied cdecle cess 59-3 Archery Structures :— Generales a as crass onus nar hae Goes ase + aerate eee 40-19 Wood Construction :— Imisid Fine Mims). sere ae cepersterets s aleteiaie ns oes oe oi eee 67-59 QOutsidesBire Mimits ages eye eieteseusie oieine erie ora as eee 67-60 Arches, oor and: rool, Clay tile sed. os dace ke, gious os 2 Serene boise a 77-1 Arches, Masonry Wall:— Depth, min. 1/12th of clearspans.3.. 2263642 fs s0e0s x. ee aeeneeee 73-54 Laid oni radius ‘of arch Curve: s< [234600 604 y vote ad wacen sic ee eee 73-54 Rise,min, 1/12th of clear spam .cs5 coy. on 5s cies also ora eA 73-54 DOG MASON EY TEGUITEE 53.5%, 6 i534 cn: ac eoths eet a tie As oa eee 73-54 Wood lintels allowed behind..................0 0c cece eee cee eee ees 73-53 Architect :— Certificate :-— Mechanical amusement device..................... heat ioterene 43-15 Mum'ber, frade-Obs 2: Seen aie cis aeic einen ae vara cee 72-1 72-6 Wrussed steel: jOIstS.2 4 .sis8.0. 42st ee See alee ee ee ee 78-8 Welding: Generali: cn¢ sitoiees chicicn.aah on Pee Eee eee 75-19 ‘Trusged steel Joists.go%. dedc.2 sas athe ohh e ee Ue eee 78-8 Certification of drawings, design..................... eee SAE 45-5 Pile cutzofiidetermimation. varia ai-rois oes eee eee 71-24 Seal on Plans cischi5.c5e.creadneq At hle sacs c/a daees a eae G0 Meee oe oe ee 45-2 poilitests: (General, 8 05 die cou ieaiste cn wom o8 ss ee ee eee 71-8 Working load determination. ..2.:. 344.0... feces eee re ae 71-8 Wood’ grade certification.:.:. .c.f55 Gs cake acts s. tee ae 72-6 Working drawings: 2... 0a0.2...00 eh. atadne coe oes eee 45-5 Architectural Act, ‘State of Mlinois:..<: 7...62245. 6:4 nate eee 45-2 Areas Dene lcs cuso-vis d6i0 @ e.g’ ue lek a dutta acd a2 cadet ee 40-1 Floor areas defined: . escnssn0hedsse es tse ve ae ee 40-1 62-4 See also Fire Division Areas Areaways: Exits from Basements:— Clear: width same as stairs..5.4... .. sao... Saou aoe eee eee 64-13 Gl GENERAL INDEX Areaways-Bathroom Areaways: Exits from Basements:—(Cont.) SSI ARITHTTIOM WA CLL pepe MY ss es <8e 5 tesielers|a dcslats svais sy sis\d.o18.e, hese iNoie MR oslo apsie aoe Simale chyna, oo Geentngacese co Saou oe memn Oana coments tat Armories :-— Capacity :— Drillingzomplayvine space; factor Oks... ..ccsccecomas.coecss cence @themassemblyaspacestacctor Onmanmeerisna sen cm atin sade 6 aie ea IDS. 6 oni dob Ges ode 6 blttae GO CCR IE ct hatin ia ee ae Piglsltie agaaial hy WES 3.5 ois 6 ot ao ald n SIEID A noe ct core Oe eerie eee AriaGalleres; Defined as public'assembly unit. .......-...2....0..2-.-0- Ash chutes: Conform as chimneys Assembly Room :— Definitions :— Gangll, ossc0t geoteeben Soerae aie Ron eer et eee eee Institutional building: Over 600 sq. ft. room area................... School: Defined, over 1,500 capacity Asylum :— MAG ATIO MECH CLA Meme eea arti pe Ac ieks oo is ictere fd SI Ns Deere ole Orso eee Onnuanecenerdlewas taper erst pei oe nar eee i eee ee a chonh eae eee Athletic Clubs :— Wefnedsasypublic assembly, units. 5........50.:---.-0- 2953 Includes :— Billard Rooms Game Rooms Bowling Alleys Gymnasiums Exercise Rooms Pool Rooms Field Houses Turnvereins Athletic field: Defined as open air assembly unit Auditorium: Defined, general TUNERS 5 5 0:0 05d 60S OR OR RO a ae ee reer Automobile Sales Room :— (Gat. 06 0:0 o OSI S SEO RUIS TIT ee ene eee 52-1 SEPala LORS wae eter Ne yoshi Se) stesis fs Sis ce as oid Sars oukene S21 52-19 Automobile speedway is open air assembly unit Aviation Fields are open air assembly units Bakeries :— ESOS CRESS WGI ath SoBe as Oe SAGE ais eR ae ane Mechanical ventilation not permitted Windows and skylights Pree MN CALLG aie chen nrce neers neice. Sei aihidie tts tive Savas aba avalnee ee Ballroom, defined as Dance Hall Band room =ROnaEMielis}\e\7e)\e'/a]\0, (0) \e1'0,\0\re)\e)(e//e)\e\\s/\6\\al!s) «\\e |e) 1e|(@|(e) sie ee) 0 a\{ee\/e/\e}'6| »\\e\\e, 0) 0 e\ 6) 0)/e\\0\ ee '6]s\ © ela) ojte |p) teje)\ule vee ee 0) /0\ si e\\e| «. s)'c) e's \e) © ele! 's: 6) s)'e! 10) .01 0\ 6 6) 010 elle 0, 6 EMEC L SeOOINS + CLINE 7.2735). 5 Vs re era 6.5 onl son bya bbe s tice sos ee ss Rela Sd Eating place Baseball Parks Basement Areaway Exits:— Clear width same as stairs 4 ft. min. width 5: FH SVG a La ip RNS gee epee Pc” P02 a OR gg Basement Ceilings :— Business units: 1 hr. construction required.................-0000ere- Ordinary construction buildings over 2 stories high:— Metal lath and plaster required Basement Defined :-— Garage: Floor level over 1 ft. below grade General: Story below first story DeoUvebe Owe SKOUNGNStOLY, «<5 woven cetacean ae il cco oto ae Schools: Ceiling height 8 ft. or less above grade Floor level over 2 ft. below grade See Occupancy Chapters 47-58 Bath Houses: Defined, general Defined as swimming bath Bathroom: Defined Onin ie & Un Tato ie a a eon Sa Rts Rm Wb 8 Beach-Bridging GENERAL INDEX Beach'inclosures...s.... Sse. 11st as 'nnide boo sic citelidled asc 2 eee 54-3 Bearing on wood studs:prohibited. 2... 0... v.05 cose pea eo ee 67-51 Except: Allowed in single dwellings. ............-.c2.c+e+evwurevseee 67-51 Bedrock :— Design of buildingsion bedrock....0.........6 4.0824. 0.0ce culen eee 70-22 Formula, foundation column: loads, 2. oi... 2... 6 fee ee 71-50 Foundation. columm pressures: ... <..)..).002 05 o¢e200s . en eee 71-50 General: od ses ck eee hae wa vided eRe ee eRe oe aS ae 70-22 Pressure allowed, 100°tons per sq. ft.2.. <5. e+ se tence ie 71-5 Stresses reduced: Buildings on bedrock..................00 0.0 cece ues 70-22 Billboards, See Chapter 58, Index Summary Billiard Rooms:— Defined as ‘athletic club. 0.0.0 004 0 pn et od od oe ee ee 55-3 Factor Of Capacity 25..5.5 23 2+ osceae eee eers Su alton A otin as cee eee 62-3 Bleachers :— Defined: as open air assembly unit. 7.2... f..h. 5 oan odinn eee ee 54-3 Garage GiStance. <2... .. 5.04 ace dste vis weteros wt asin tau ts aneice ie eee 54-8 Block: Defined: Provisional Fire Limits..................0c0ceeeeeueees 47-4 See also Square, General Index See also Block, under Frontage Consents Board of Health, See Chapters 9 and 39 Board of Trade:— Metned asibusimess Unit. 5. a asecec nds «2 one eee iter ela ck eee 40-8 Defined as public assembly unit...................... 55-2 55-3 Boiler Inspection Dept.: See Dept. for Inspection of Steam Boilers Boilers: See Heating Plants Bond pmasonry wallstic cc e ue cance che ems ieee ee Ripe eee 73-43 to 73-45 Bonds :— Billboards, signs, and signboards, $25,000.00..................2.0005- 46-22 huminated roof signs; $15,000.00... 6 oo cece ccs cree cw eevee clover 46-26 Indemnity, Dept./of-Public Works: «.: 2... ceuacse ag ocean gece soe heme 43-5 Wrecking, $20,000 to $40:000%5 . ora nne seas ulcadns «so aeenons Shee 43-20 Bowling Alleyst ati sti + c.2 src ele diese Anes Se re a 95=3 ‘Tii-5 Bowls: Dehned-as open: air assembly unitscs+. 6.200045. «ass eee Peeing 54-3 Boxes :— Open. air- assembly unit. 3c 244s cae ene cise oolcan ee san are ceysee 54-65 Ui Ca tres Wye ec eee ogee A ete or eee ere noe 53-56 93-131 Breakfast Room :— Multiple dwelling... sics¢e.ceeosstesseneese neu sews 48-41 48-43 Single: dwellimg 705, sas1s 6.8 6s tnoaic ols scat ola glances ards GIO eee 47-9 Breeching, smoke: See Heating Plants Brick :-— Glass32 Ins TN... es neocon & oie Startins Hoes Ee ae Bose a Rasen 73-13 25 itcmax, panel lengthy, 1, oye wes cre = stgies onesies See eee 67-41 Ordinary construction in dwellings :— Lath and. plaster required... ecents on seas See ae eee 67-53 Wood frame construction in dwellings:— cath andsplaster required 2.5.0 -sse wacieee ete er ee 67-66 Céimes Defined. ac xcs ag asGes nee s+ 2 48s ak aoad ron ee caaeeeta saan 40-1 Ceiling Height :— Business unit :— (General eS) Et aimee eae ancy tere ce ress negra eae eer tee ee 50-24 Mezzanine, 1,000 sq.ft. or less, exempt..2. o....6 fae eo nenne ve menos 50-24 Mezzanine over 1,000 sq. ft.,.8 ft. min... 2. ncn.5 c2.< os sds wana. 50-24 Projections permitted below, up to 12 in............. 50-24 62-5 Storage rOOMSEX€MpPl. sj .noe ee so hee eee ote sre ects Ae esrotees 50-24 Church :— Assembly rooms 12. ft. mim 3s jeiteras «fee eit each dis capnisierenetsicr oeuetetienere 56-9 Balcony: Need not exceed $ ft. over or under... ...6.0. sis dvs once 56-9 Sift. min) OVer OF UNCErs s..00.5 24 noe Aes nee) 1 tienen See eae 56-9 General? 10 ft) mmm. o2 So eae cee ers tseiare endl > cieccere ehcreier eee 56-9 Measurement :— Level floor to low point, of ceiling... ce 5. oe ict epiele cuoerepoeneees 56-8 Sloping floor, high point, to low point of ceiling.................. 56-8 Projection, 12: im: Permitted below ceiling: . ...'... 5.20) sige deme ceeeee 56-8 Storage room: (ft. MIO 22 6 occ8 os cantaanais gaan alee 1eueme nape 56-9 Moilet room: Sit. qin. sie ve ec cee averse ave Haein eee eerste etek Ren 56-9 Court rooms: 1Dtt. min: . 22 yc keen nee oa nein ee em Omen eee 58-22 Institutional buildings: Sleeping rooms, 9 ft. 6 in. min................. 49-11 Multiple Dwellings:— Siftitor (5 ot Hooriareass 4 occstetichs cc Hittin Give OPT eee eters 48-39 Nurses’ home in institution, 9 it. Oi... 6.0.5.6 wee cs see 49-11 Open ‘air assembly unit s:S Pts... 356 v.05 oa aterm cee cheno ene 54-22 Police stations: LOMt. mitizs. © .cjceseceishe eee, qawie se Sscepeystereie = ene Ee 58-24 Except: Cell BlOCK sce s s:-eceue « vitetn sere nyse says « wet eee cect nee rere 58-24 IPEISOMS, C62 5 oe. cco sus woods os feces loan evever dh otanie etal al enn gle OVS FIERA Rae 58-22 58-24 Projection: '12'in., permitted below ceiling. .... 5... cern oor ie 62-5 @ht. ming from, Moors «osc. + sips ciceveeec ye sere ays sh oO Romer aes 62-5 Max. 25% Of HOOT ATCA. iocsc 5 Sch 5.0.0: or2i avayocd @ s cuate gets ere Reon epeaoree cee 62-5 Public Assembly Unit :— Assembly room’: 12 ft: mins... a2 ent acts acca oo 230 Seer rnenee ewer aetenet 55-15 Gl GENERAL INDEX Ceiling Height—Chapels 11 Ceiling Height:—(Cont.) Public Assembly Unit:—(Cont.) ipaicouy-Need not exceed ’Sft.over or under. ........:a2-.....-5-~ 55-15 SHitemIni MMO VER OLMUMGehe «2 5 qelsiees c leveisegeie le c)tan cas gsc ee oe cine - 95-15 (Closets 7 te TCU 6 ere 3 aio REPRE St et IERIE see ea rea a i et 55-15 BG uipmMentaLoome/pltyimMiMermcpeetier sess ee Soci cli, 2 Sree omy stel Ioa19 Co ERED ST UTES oR COS appar Re ERO I nae Spal§ Weasnnementidennedmrryy i eae aoe ei cis oncia otis 0 Se eres eye 55-15 Reon Wrtiln Cease ul Thee se oc ons o> Ga ea on Ce SE OnD Dion cee ae Shel) SSNS, DCSE TC ALES 0 a eee ee eeepc ea 55-15 SLOLAE CRLOOIMS aM /pLe sw IIM ae te iaraee tyes a yarn cles Gian ors 200) s Fyoe events « 95-15 MOT eeLOOMS Romie sg orc eey- Ret ees ceen| OI ers «6 sis ee eae be 55-15 PMO uelepaineel Ophter eras... Syn her cehtterny ec ics clas Schein « D=15 Schools :— PNGSEIUDVALOOMS eE2ettenMaINit tie ye oes atyaegaR taunts nee cette eraciee Soule 57-16 HalconyesNecdinot exceed Siit.; overior undersn.. 2-4-2 ase eee 57-16 Cafeterias: No mechanical ventilation, 12 ft. min................... 9/-25 Wathymechanical ventilation, 10)ft. @4n,mimyo2.................; 57-25 uinchessiromeoutsidemexempte. samc aaeeciee ea. coe eee ee 57-25 Glass rooms: Area 200)sq: ft..or less? 10 ft. min.. 2-22: 2.5. ¢ 25s eno RY io) Okra JNO Seite Sul si erlhi eae ee toncnS sue oe ae cote aan tee 57-23 Gyrmmansinnines Wiis j0 eae eo ae Soe aad deta eeicaudcd Ue eee se Oar 57-16 Measurement: Floor line'to lowest ceiling line. .2.-................- 57-22 Ela oomsce Opitaminererermysc yeh citi. oc iS eerie meio hacia ee 57-26 projections) 12\in- permitted below ceiling-- = 322. 2.---..2------c-s: 57-22 Necreationsrooms-lOlit-amin..=)- 5. feces se ae race cc ee oe ee. 57-26 Rooms serving food:— Nomnechanical&ventilation: 12 4t-min.. ..-22..2-2.esee4- 58 -ss ee 57-25 Withemechanicall ventilations 10ft: @im. min.:.7...............-. 9/25 Wunchestromvoutside exempt. 2-6 20. oaea nes ease eens oe. 57-25 Soucyarooms200\sqa tt. or less: 10)ft; min... 2555..----..2-.224-4- 57-23 OvermZ00 rghit 12 ttamin so: ure 56 tone moeehie oan ate eee 57-23 MNGIEtEROOMIS OMEN sere 6 oe oc Senet ays seis Gane Sar eee negro oes 57-27 sheatresAuditorums: M2tt. mine. | 2.552 ee siaee eee eee clos Sac oeioe 53-25 Except] OMt. min, over or under balcony.......--.-.scss-9+++-- Ski) fl OFEaermin’ wOver Or Under mezzanines se eae a. ee ee 53-25 & it, Giri, Wiaalepoo SouOusaaueconsdocods saasdcaoucceneanoucde 53=29 siieatKetexdtacOurts.omtelMiClear? yee soso eins ae eo eee 53-87 Miientresprojecuion rOOMerSiits MIN. sane ose ee s+ awe eseee See) Tramstionangy Wellies to} anes wil ging oooe oe oe badaooududaudden al sooceo< 61-82 Wamltsmsrandard reproor-pelertsmin. 9.45 sereer occ etme oa eer 51-21 Gel ciraw IW etre Ure: eee ene Ses tore Nee oes arose sold oyu she pptreaei de tle ge cithausacy es Parle eens 40-1 Cement :— [Payr(il TOV. 3"a'ih SREY CERO aes ern Sat ot Sn Oc clan einiohee aes 73-14 IMTS OTN, 3 See Pea ene Gio Bhat een tienen i oytrere eta Manic Guilin Cy aistontee 73-15 INICTHIBIR o, 0-5 a OO OTe EO An ow cor ore ae eee 73-20 Certificates :— See: Annual Inspection Elevators Structural Engineer Architect Plans Occupancy Chap. 47 to 58 Certificates of Occupancy :— Capacity for license :— [BAUSTROESSy COTTE een eS RS aOR rr cya oes cL eld Moment eeu a3 Ana 44-2 (CINUGRCN Sg 6/34 chee Ree on ined aco encromieciod cimitracs « orite 44-2 ELSPA ere ca evans, uh Lessig art eeavoray oe Greta gener ee ed 44-2 Onenkaigassembly suit 25. .ceiss ci seen oe Lean eee ie 44-2 ui pliczassemblysUnit-.(5 2 o.:)s arses tee oer eee On ne 44-2 SGnOGll. a5 dan AS Co Cin bon Die Motner San Rais tein Aer 44-2 “TRINGEN Tala ca, Sets oy PLCS ORR CRC ER ES RCL Ne Sic A RECT A EAS oe as cee Sten a ear 44-2 Multiple dwellings :-— PNG AN COSOCCU PAD Cypawersi's\,s sie \aveucrs eee scatterer eye Payee a, ole eoiche) asthe. arava 44-5 (Gemerall pee err e irs ovr s3..is-0is, «SUA a eetces Bape ENS TRAE OEE eis ales Anger ot 44-4 A OSCI ee CSSD Nee ce aS or See ie RA a ee erent Acres naka 44-6 Wil GLAILLOMS Hamer cacy teria a ance RM Pere /el cir karte cee oes, oe aia ane 44~7 Whanveloticlass-;see) Converted, definition. \..........0--s.t.sess.oses 40-1 Chrayecils, tinker aches encere ceireacais 0 4 Br obs Op BS ROOD E oer RETR SAE 55-2 12 Chases—Chimneys GENERAL INDEX Chases in Walls:— 8 m:imasonry requirediion' Sisides... .. <1. 3. +21... neler ee eee 73-52 Over 24 in. wide; considered’ openings. 2). 25. 5.5.00e sk ou eee 73-52 Chemicals, See Chap. 51, Index Summary : Childrens’ ‘home? Medical and surgical’. . 2... 502+... oes or see eee 40-5 Chimneys :— Air space: (Concrete chinmeys: 2s. - 0. deco. coca - 76-25 76-24 Exterior masonry chimneys: Same as for interior masonry chimneys. . 76-9 Air space: Interior masonry chimneys :— Circular, over 30 in. least dimension. 2 in. space...... 76-25 76-24 Octagonal, over 30 in. least dimension: 2 in. space... . 76-25 76-24 Non-circular, over 24 in. least dimension: 2 in. space.. 76-25 76-24 Non-octagonal, over 24 in. least dimension. 2 in. space 76-25 76-24 Air space: Interior metal chimneys:— Ain. continuous through rool... ocee. sick dese se ree ee Eee 76-16 Steel in space must be/fireproofed). ..22... S22 scteeas nee scam ep eae 76-16 Surrounded by brick, tile, or reinforced concrete.................... 76-16 Air space: Isolated masonry chimneys:— Dan, min.ito chimmey: walling <:ascel. asso area atts s+ a cena teeaccol eee 76-24 INSINIGHUEES Aco osc rstavee tere vers ers ieie er h evehave ates eucheie stat eiere 1c eucie da eeteeee eae 61-21 Combustible framing: 2 in. from outside wall........................ 61-90 (AD, MIN. TOM INSIdeOl MUG. es. wy csc de ne Oe eee 61-90 Combustible supports prohibited. ..............00 0.00 cece eee eee 76-4 Concrete solid units: Allowed in hollow exterior walls 3 stories or less. . . 76-10 Design: Combined wind and dead load.............. 0.00 ccc ee eens 76-5 Foundations: On ground, or on 4 hr. construction.................. 76-6 Wind loads... ae cocaine mae etis yee Si ee Ene Chutes, Water:— AMMUAalINSPECHON «ane ae ese re eee be ee ore ste levee Exdts emergency tccic hate ners ine mae ee ere ne sence =e) eee eens Permit required. Achaia abso uct eee eee eee 43-15 Plans required ¢c043 crud. wcaaesicet hase ee ee eee 43-15 Protective: devices? sais sete os tee ee eee 54-21 See Amusement Park Devices........ 54-14 54-21 See Mechanical Amusement Devices, Chapter 79 Circus :-— Buildings Defined,.2 «a. koe eee eee ee 55-2 Capacity factor:— Exhibition space:factor 10.3. ccd. euttes eal sees oy ree ee ene eee All other ‘assembly Space; factor 6; < . 4.:..-05.030 seteuehre are eae oie Tents: Defined as ‘open air assembly unit........ 5.22 22.2 « csoeesoryers me ee Ventilation: Arenas cso ss cc)e cee cicuciaie ives tens te a ha tera ree te Spectators spaces ies LU cant Salsieces eats ios oho eee eee City Engineer:— Plans: Building foundations over 25 ft. down... ..........-.-22---000: Classiroom Defined s...<.25 52 cae cen s side cis do oare eC er See Chapter 57, Index Summary Clay: Tile Floor Arches! oo. 2.5 4 ooo ca eonie oa.n's is Ate EO ee Clay Tile: Structural, Load bearing:— Permitted: in walls... s..27 201% Seago oo Ree: SIZESS SPECIAL a acco paisa, dos pr4 Rare ede ne tans ars 07d ete IE CRE Rone Standard). oo 4ceccs oc btcciaie sof tied do Bo, 08s. BS ene Gl INDEX GENERAL INDEX Clay Tile—Commissioner 15 Ghysiule- Structural, Non-load bearing. . 2... eel ee cece ce eeses 73-5 Clearances, Heat Applicances: Walls and Ceilings:— General eee rey cc others Seema sila ce nes einektns wander 80-4 Furnaces :— Gomemall, 5 da.6 ob 4dinanos aoe 6b oo AS TORE OU CIDE iron ee tee ae tae ae 80-4 JONG S bao Bop cad ee eS Ais CER ERC EAA NREL hoc ee eee 80-26 80-17 MAgOnIny CASINGS, soc 6008 o6 acevo denenboon oOo UeeEbood ecu aD HOUS 80-16 \Wanaan cia japan eval Gloves), al tS oo Socoodens obosu bdo aEa Cae bauode 80-17 NV AEIMIRA LTE SHACK SR ten OO Artccp or cise ne clo cashate watSinei ss a cvs isce ie cum ieielei ete 80-17 IRCEREIEE 5. 2 oth: Gee le Eas Cista ia ot OLS aIt Cn Oca ROT Reon Coie e 80-18 Pipes: Over 250° F.: 1 inch to combustible materials.................- 80-26 Clarstiense IDSIMNEGlS 5.6 ARS iee oRISe Nears ian ceo erie eee emcee otereanin ae 55-3 Capacityatactor 2 Ole rvan via recs pene eas aie os ore dniele echo ens a etey= 62-3 CHESS. (EC ISE Tio. 5 eee Creates osoeek Cm ae Rca Ne eer ne oe i ace 39-6 Closets? IDeitineGl,.:o-2 25.5 Beet ooo ee Ore ee niche ae Eee ora 40-1 Club House :— aniaomopenraitrassembly Unit: (acca. sss os ose coe sos lace 54-8 WathesleepinpraWartersme arr. ctsepr ie chewies oS )-\h.2 eeeethoreters «st onsen 40-4 Cold weather requirements :-— OOM CLL CHM Pe Te ere r aie coec arses nine ca eiare ieee mtn etetav ane srised ocatpncisd eoucoler an ela 74-8 IME SODIAY so o doled Cotes ODO ORD naar nee Pere ee ae rice ec 73-56 CollomimaGles « 6.00653 GAIT Ocean Te IEE eee es cr ar 55-3 Columns, See under Concrete, Steel Const., Wood Const., etc. Combustibles: See Storage restrictions Commissioner of Buildings :— AND DOLMETACINE, 370 og nolo 6 ob CORO OO DORE DOM D Once Rep Aen reams onion 13-2 Appomtmentofsubordimates. .......--.. eee ee ees 13-1 13-2 25-4 PANE Rb el OME ME ee Ne terers sre Ao ena Siete lai wise a) Seles cif Busi s akeialsicacldeewonels 13-14 Authority :— JDnraeenoney lyunllehinvas on opracioes God Soo deoe Gao atone coin Soome OF 13-22 13-23 Wecisionginalsurgent cases -si-ris siweien Oreste cei ie eterno elstele 13-23 ING LIGES Mere eri a hava ols iayers cvote 2 13-22 13-26 46-19 “eae clog: loi kalts¥23 > \ atatemm eras Se cio cin onic cio oon cake ooicmeronns 13-23 Tisai? Gorm aOlhiOnis doc uaesaseneomes aumsadoobe onisedoe Garey aoc 13-24 Winsathesto ual Gime Siewert een hoe ieee yoo skies oct SNS Ta uel sects ei ehonsuoiier aeereate 13=22 - 13-23 WRC SMtRGASES argere rey cyan rence p overs as aioe oxcreucreys nie) sv letindn ormionensusuoneitelaactetena are 13-23 iBillvowmers for ExXpensess:.......2 +. 2--- 13-24 46-20 46-21 Bunllcdinggordimancesywaolatediecms sie ccme cas oer ae -ise oe otic clash er 13-24 Certificates: See Architect: Structural Engineer Chimney, isolated: Approval of masonry units... ...............02s+0% 76-8 Closes urldimeoce a: we emrew res ee EN A Mays onscainceaive > syareieveichavenor utes 39-6 Commiussioner of BublicnWorkswess sacs a ae eeis eee ele ee ote 13-24 Constructions Mowe tOlStOprreme cites ects see eter loser) ses obeneaerel 13-25 DWIScretlonaiysMVOW el aioe cee hier oe ck oe eo erie ethers 2 13-14 Duties :— (CRTC Pan craeronre et Ula Omi oticin acicie nercth cd cls Cine tice mine trait 13-26 (Generals. Ue Sia serait coss SR tok, STE cee aS ER ae vette 13-11 Inspectiontoibuildingseareeeerec ecm een reece eer 13-19 Notices 13-22 13-26 40-20 46-21 Renmitsedallysremortst, cvie.c etn coe sis ase eee cio ieie ee icenoaeie aieieeerens 13-28 lamba provalSec cccks snap: cicseis apsnclcrciens ie eubohe eek Sm oaleicns eee iionees re 13-20 Riankexamina tons esc ee ecm Oeenere nao: 13-8 13-20 Rowernstoumakernuless.: bes, <.3<1ccthe nce bec eonors arcielateu te a Gea a Pe 13-18 ROwerto; pass OnkoOrdinances. js snoeeree ce comet eee ila = 13-13 RECOGG Soe ty coor Ledsca fo hues sob a RE. AB Dasyee RTH eR nas 13-27 [Sia of ONS sVa) ah once cae ne Ree cetea eleerenecicc ne END oeitee cect 13-1 13-3 to 13-9 IRVIN, OXON KEIO) Bo Ad ee Oren RI RIAESRALS Oreseich ea cr cRe NCicLo Lotta CAM EERO chale oho 39-3 Iinspectionvor oul dings2 0s... ceaeenevmer erearens Che oreeie sy ausness) cleaeue weieloee miele 13-19 ialpilityayperso nal tearaeert tec vaccinate ernees eile vase caste sac a Heoayg aileaeaS 13-12 IEICENSe ne VOCALLOMM ser aety sea cetera easee eaters oa ROMA ETE eee eee a 39-5 OxdinancespowertoypassiOn saree cen acelin aera aera: 13-13 Rersonalelialility ayy perc nin cre nee a SALA hse ee islcwsy ci haia es seals trotted engi 13-12 LPARETOSIS Ja\f0) OF CORTE ba a oe eye to MOE Seto Gb RACE UR TEC iene MR ra tine nee caeats 13-20 Examine tl OMe ee Be hora eee nee nossa cava 13-8 13-20 Rolicel Commissionemuofassiscemmaereeriaerer eccentric ie 13-29 IONE OH CIMT o ot Ges Baie RSID COG. Agia e aoe he nce Ore ecm c 13-21 Gl 16 Commissioner—Convent GENERAL INDEX Commissioner of Buildings:—(Cont.) Public Works Commissioner to assist................. 13-23 13-24 Ruless power to makers. seeman eck ya seen are : 13-18 39-4 Stop Constriction.......7.sc.1. bow ele Gas ee tee ie see eee eee 13-25 StOP SWLECKIN ca. cccekes aesv stad eyes tree tee ois ee AGE 13-25 Wrecking* power to Stops: «ar. 87's supeie.. oe gaia we seek lee ie ee 13-25 Commiussionerof Police to assist... . casa os mbes osc eee he nei bere eee 13-29 Commissioner of Public Works:— Balcony over public property =. sac «sae es ee ioe oon ee ee 45-6 Bond indemnity acc cee ore ete etek ue iia one ea ere ee eee 43-5 Buildings encroaching on public property.............. 45-6 71-2 Canopy over:public property. 2... .-esee ess ose (ee nose wea eee 45-6 DTV EG Way Saree che, rive: die ere iopteretersines aia ie Ge 73-49 Wppenmcourseitosberheaderi courses.) sss ace ee as oases sees 73-49 (Conner Ihett, COmmEGL. oo.) coke arene Ea ean o COE CO CRG Deena ere eae 40-1 Cornices :— Combustible prohibited on buildings over 50 ft. high.................. 61-92 Non-combustible required :-— NUE icine svovern SOG. highrise etecictre oe seiac «see > ol slctetens 61-92 HEOVECHONNOV Er Street OF alley. Gif ou cae tee oe bee eee ntineae tase 67-56 Wihere shee Constructions required. wre ace ce seemeet . ocieiemirs 67-17 Where Semi-fireproof construction is required.....................- 67-34 Where Heavy Timber construction is required...................-. 67-45 Shallinotproyect over property lot lines: =: 2...5:.0-2--+-+2+--06- eee 61-94 Wallttoybemullthercht behind cormice..4..5:.[.2.-.0.0..-+.e8 essen ee = 61-93 Corridor Type Multiple Dwelling :— ID G1aATNOT 5-5.0: ca Bon Gas re ee Oe ee rE Ieee eee 48-2 Wood frame construction prohibited (See Chapter 48, Index Summary). 48-38 Corrosion Protection :— ERP Ose Cente valEstnu ClURCSMepsie cy cermin ceva oe felapdeeeneve tava oi daye oe mel oe 58-87 to 58-90 Poor gine! ROO! EAS. 5 ne eee asda made o ctecmon ameeicmoa maemo < 61-102 Mortar > in: on inclosed'steel (mot concreted).........0...-----2505- 61-101 SLCC OOLSMI NSIS ie ta. = oS oh lea cabow Son aa estigo eters 61-102 DUBE TOUS 6 ‘oi ce oO ARERR oe Rec Se ee ae ce ae ar error eee 61-102 SURUCUUTAl ROLAIN COMIN, see eae gieit wn. SUF on vee ancien | MEME Siar aces ee eae ea 61-101 STRAINS CaN ORE 5 As less bo oi cco AY SUR ORS GaSe eae «eas 58-87 to 58-90 Goummenlech ara benseewpwtet a SEES Cyan acdsee Res thonersicv ela tee aici e resi 5So=2 Courts :— ICES SMITE SNM en eB area. = ia Gears dei SieaPites «cols sio ear be OO 2 LOO ID tinned ee ER Ry Metis eek chs SEES, Pot cucace Gms e Sheu Mad 40-1 Exit courts:— Mbovernrade: same asurOol exitSw merc. smieie ss selec ee is ei eicie eels = oe 64-12 Weadidirectly, toropenispaceiatierade.s 52 4- eee nee cece os = 64-4 Onmbyatireproolppassa seman yep cu-e cereus tee ueierierr cree casio che) ote 64-4 OTRLOISUREC EA nets Pee Cpe Oe tious vas se peeamue eaten 64-4 Orptora levees cco eee erate ee estas ret ticiersstantrst gas tese ie eee 64-4 Manholessidoorss pipes jetcatombemlush... ysneeee.s- 0. eeu tate ee: 64-12 MINIS GH benDAViede sie sh aie Senin nt cree oe sions, < car nea Soe AR 64-12 Obstruction pronibited yaa seme se aeck, nes acces Sa aoe Soe 64-12 Ram pseslopemotiOver laintOmer qemas > as necsceaare a eos ae 64-12 IN OEE se Ree aa ES tir 2 A eee Ee terre ce 53-48 53-84 Bxdisnequinedstromball Counts aaaarcia- eee ree oe ate ta 64-12 Hazardousiuse units. .4.......0.----.- 51-6 51-7 51-69 JamaaysreS 1D Es thaVe( lear eRe ern R peter ts. ctiole Anteaters cle. oleic be 40-1 48-2 Binevescapestnynn er COULES xs ae eewaeetec ieee Shickarete oh aiepeuers cre ore 64-14 otslinexclosed:yDefined > 5.2.27. a-soaeateme ot aens es 40-1 48-2 Kotlinevopen:Detined esos acasneeeneeneem ee sae. 40-1 48-2 INOHErectanculan-e) efinede ia = Seer ecient meter ee 48-2 Eublicrasserblyauinitesser eiscce aerate ein caer - 55-6 50-2 ectangulanwDehmedie tian: on... violets ates Fone oh oe Nee orca Hs 48-2 ‘Through court: Defmed!............2.. 40-1 48-2 48-17 (COTE IRCCS 5s Gola cet Re re GREED RGe co ac-c ot oer ocean 55-2 58-22 Cupolas: Same as Spires (which see) Curbi Grade. Definedias\ordinance elevationy.....5.s05..¢0s0202 40-28 -oe 40-1 (Cini Coe ears oh itd... RR MERE trot habla tity Bok war a nets 55-3 Curtain: Fire, see Proscenium Curtain Proscenium, see Proscenium Curtain See also Proscenium Fire Curtain in Chapter 53, Index Summary Cut: Horizontal distance between successive rises......... 40-1 64-25 See Stairs, Rise and Cut 18 Dance Hall-Department GENERAL INDEX Dance Hall:— Capacity dactor 18:10). 5 ise ocee weaectsic 3%) oot Shs eee ee ee 62-3 Detined: Ballrooms:,:). s hae apne on tated Behe Peek cic Someone & sie wee ae Sean ee 82-2 Public assembly Winits . 508s is 'ae ae cheb, ee eee ots eer ek Dee 40-16 Public assembly ‘units, terms. cs! ac... ohas e150 hea enantees oAREEEE SOn6) Public assembly units, types: .. cc. . scc ee. s seins weet a accu wh os eee 39-2, Refrigeration, mechanicale ..¢..c.. 6.05 os shane soc ad em ae an See 85-2 SCHOOLS ees eae eee ene ae eae ree 40-18 5/-2 SChOols, stERNiS sss, s...s guts oka ka Sarne Serna uaa Oe ee sa eee ee ee 57-1 single dwellings: 2c...025 crac oy at ee oe anne baa ty a area its ek ee 40-3 DOUG coe. ad iad tus die ae Oeie enaty eam nee oak tee aust ha, ties ai eae 71-5 Stairs, CErmMs veces cos encanta ene nan oe eee ae ee 64-25 DNEALSES 5 sos Se dyetmere 9 en « meee gee gorsende Saye See se ee 40-14 Dheaties,herms;. . 22s. conte ane 5 ag aed eeeaal ond shee eee 33a Ventilation, terms vac Adeat a. osu austhienin ass nie she eee ae eae 81-1 to 81-4 Department for Inspection of Steam Boilers:— Boilers markedion plans... 27a amatn «tad eons eee a ee ees 43-14 Except: Multiple dwellings, 3 apartments or less................... 84-1 to 85-1 Single dwellings... c:.cu daw decks Lae weds ee eee 43-14 84-1 to 85-1 Inspection: f£e€s cere «oe teue.ceipoe Se oieteeieug a atereaen iol a eee 43-35 Department of Buildings once. des echoed eRe talon ovtoe eo pO ae 13-1 Department of Police: see Commissioner of Police Department of Public Works:— See Commissioner of Public Works Department of Smoke Inspection :— Building plans to be approved’..2. 2.22 ca. os... 3. Pca oe 43-14 Except: Single dwellings... c:5,.22.00/4- » usot eR ee eee 43-14 Except Multiple dwellings 3 apartments or less..................... 84-1 to 85-1 FOES oo oie ia Pwiie wawd a dann ae hued nde a eae cn eee eee ae 43-35 Fees remitted :— Charitable institutions: «22.0280 4 wns cso ee ee 43-35 Educational institutions... . ¢..-.:esa.cit se ee eee ee 43-35 Religious institutions. cc... wen sles te eke ie tcc ee ee 43-35 Gl GENERAL INDEX Department Store—Doors 19 Department store: see General Store, Chapter 50, Index Summary DeEpuig Commissioner of Buildings... ..25 oss. 0-.soaesurc sees este unaes 13-3 Derricks on sidewalks prohibited for buildings over 4 stories high.......... PT i sta nce ck eins c HN einars wea oars 61-10 61-12 Dining Kitchen :— wil ieeehS CSN Rs ei che ai Gece Sis SCA ey aa 48-43 Sie enGyye linn 5 peepee er race ees useuas ye ess aiciiat yore ites oyd..s-d. avd: 2 Sysiel dace 47-9 Sze alan Ixinclagin AlOOGo code oteeasoanse dear ancebooss 48-41 48-44 DUI CMLOOMER I eye is PATS AS Score edad bs okie aude eddie oat ae 99=2 Ss IDYiRseornal! SIG 5 obits ace Ee a AI eee Oe eo eee 66-10 to 66-14 See also Signs, General Index Documents, standards, materials & workmanship......................4. 41-4 See also under American Society of Test. Materials Domes: Same provisions as Spires (which see) Doors :— Clear width:-— Defnedsnet unobstructed width when open.............-..esss0-- 64-21 Obstructions not permitted, except 4 in. panic bolts................ 64-21 Communicating with other occupancies................ 63-7 64-7 @oncealineidrapenessetc:, prohibited’. < o.% .. 5 62. ses geese cess sven e ts 64-16 Moublerswineine, doors permitted. 5. 2.05. . sce e es eens sees 64-20 Emergency exit: 45 min. type required to exterior stairs............... 69-16 mheatressimayeswine (San OVeriine: ..05.....5..06.00sess ess eeu es 53-109 Fire: See Fire Doors, General Index Pimevescape.4onmin. type required: ...-.........s.ss-- 64-70 69-16 Rizeyescape=|Wnderor within’ 10\ft. of fire escape. ............-..0-.-< 64-70 45 min., Metal and Metal Frames Required :— When located as itemized below, in:— All buildings: Except single dwellings, any height, Except mutliple dwellings, 3 stories or less Locations :— Courts under 24 ft. wide, facing other fire area openings........... 61-40 Fire areas: Within 9 ft. and 150° of other opening................ 61-40 Within 4 ft. 6 in. and over 150° from other opening............. 61-40 imbpiiresshiel distairserwrmrryeo et ote errr are 64-49 64-50 MBS Cain CLOSURES! ty yeces eee: cis G24 Piers ockecan potas 61-24 64-28 Except: 2{ in. wood door, dwellings 4 stories or less............ 64-28 Over combustible roof, within 40 ft. vertically................... 61-40 Within 24 ft. of and facing opposite side of alley................. 61-40 Wathinel?) ft. of andifacing dividmeilot line... 25.5... 2.56. .25-- 61-40 Within 24 ft. of opposite openings in fire wall court............... 61-40 Within 0itt. vertically of combustible'roof...........-+. aaee-e--- 61-40 In stair inclosures: 45 min. doors required............. 61-24 64-28 Except: 23 in. wood doors, dwellings 4 stories or less................ 64-28 Mocksitoropentrom inside without, key.,.....22c0¢+em. oe aeons eee ae 64-22 ixceptions Correctional imstitution .-)..222-5- 50+. 40408. see 64-22 erraleinstitUtdionbeeer he tee wee ern ie er ne oes Re ae ere ce 64-22 Siiaale Chien. ee eno otimeat Sura OC Or ae DEE ooo ae eos 64-22 Metal and Metal Frames See Doors: 45 min., Metal and Metal Frames MinrrorsmmEdoorsyprohibite diac pre wee ieee ieee ere: 64-16 Miuistabemeadilysvisiblesco. .c.c.. oshe weitere Deere se Se aie 64-16 Outside Exit :-— iPmergency,, theatre, may swing 18 in. over line... ...........+...:- 53-109 Lead direct to 10 ft. open space at grade, which:— eadsidirect to street or alley at least, 10ift: wide.’ ....2..-..-.4.--- 64-5 Obstinictingerress prohibited: semester cece cinerea 64-18 Brojectionlover property line probibitedi..-2- ac ses cess ceria: 64-18 Except: Emergency doors, theatres, may project 18 in............. 53-109 INGCCSSSS Naa AGLI COUNO M3 ..cnigosanvoudaoncugudusandecmoanaGne 64-18 Sliding eserohibited asiexits eee Sere eerie ater air 69-26 Swings Opamoutsidepassagesmrrat sire aeloei seis eters erciare ideals cies 64-18 Swi Catone oseuwatiay trait Grrae):erre cere tcrie ticlercieisreie weiefasie -e aysitareere 64-18 Swing Out:— Except: In 1 story business units, not over 5,000 sq. ft............ 64-18 Ime earacess@ lassi ge secede terns faye icte. crass sorter eters, cio eid wi 1st 64-18 Gl 20 Doors—Encroachment GENERAL INDEX Doors:—(Cont.) Outside Exit:—(Cont.) Swing Out:—(Cont.) Except in multiple dwellings 12.22 tcqes.ee ve no-cd 64-18 Exceptiin. single dwellings... .< .poceea: se ee dei sete So coe 64-18 Revolving :-— Annual inspection. & .3.¢e,.2 seas eae sie ae telaene caer aera retake ee 46-34 Clear width only counted as exit... .0c2- 4.020. -aetias ce cee eee 64-19 Collapsed-clear-width: 20 in. minis cincas2 oes enue es eee anne eee 64-19 General provisions.o.% sic cnsan wees ws one ae oe ame erem ees 64-19 Glass panels, shatter-proof or wire glass..................22.0-000: 64-19 Institutional buildings: Allowed as extra doors..................-4- 49-27 Multiple dwellings \ 0. eee sore oiae ret ea Se oe ee 48-58 Permitted:generally (252.1. ¢0e 2 eee eee eee caine + nei eet ee 64-19 Prohibited in :— Public’assembly: spaces. cea ss-ccae Sere wee cor mittens ree eee 64-19 Schools) (Class lees. mn. een ta. eee eee 57-54 64-19 Theatres nein canine te ieee thea tet Amie locate ene os, ee eee en eee 64-19 Schools, Class II: Allowed as non-required exit....................- 57-54 Sliding: Permitted when not used as exits... ....... 0.2.00. e ee eeeeeee 64-20 Permitted.in, elevator hatchways.s.. 2... s0.5 ee. cs5-saueaeres coe 69-21 Prohibited as GxitS esi cc2areia snes yayets nel eae aare eae) cramer eee een 69-26 Swing in exit direction :— Tawverti¢al exits. Sees onda Sane aaa a ae ae pera ee 64-17 In corridors, lobbies, public spaces in :— Churchese 2... Maes octet neva, ates as er ree a Oren Rae era ee 64-17 Openair assembly mits: \.e- mae sks ot ne renee scan eee 64-17 Publicvassembly unilts:.c west ter eee ce aren ete eer ee eee 64-17 SCHOOIS I 5 tui Os UDR s ine dieven atc ane «Ofer co eee eee 64-17 MEATS ic. doing sree oe Tee ee ee ee ee 64-17 Swing inwards in certain habitable spaces.....................00005- 64-17 Dormers, Roof :— Masonry construction required when :— Length is over 50% of parallel wall below. .....................04. 61-50 Tobe. same Construction aS TOOL. «4... <2 ce lens sere dateracsts octal 61-50 DO WNSPOMtSs.<.2,ccsert wen ever eens Sere creneter horse eR EERE ene eee 82-63 to 82-65 See also Chapter 82, Index Summary Drawings: See Plans Driveways :— Permit required, Commissioner of Public Works........ 43-8 45-14 Taniks tiders. sos oo ce sieaia ecg te sedis s a coca eee ee eee anne oOo nee Driving formulae foripiles.. 22, 2. .sasteeece ose e nse ss oa ans eo ase 71-17 Drop HAMIMET Wie svsechs/le ir ee eho aoe eee eee aan ae re 71-17 Drying room: Standard sss cases terns eae tetas saan eee teeter ee eee 63-2 Dwelling, Multiple: see Chapter 48, Index Summary Dwelling, Single: see Chapter 47, Index Summary Easement, recorded iss..cacc ny occ oo 8s oa bree eo be ee ena aae ee mses 43-3 Eating place: Capacity factor. ....c0 en Sees de se eee een 62-3 Wehined |. cickis toc cece eee Sete te ete le ee a ee eet 55-3 Eaves :— As fire-resistive as’roof Covering.ay... -¢-54 dn. oo Ae cae eee eee oes 61-47 Non-combustible on buildings over 50 ft. high. ...................... 61-47 Electric Units:— Mezzanineés in power plants: .4,42....2 25 92.2 0. 42nd ne ee eee ae ais oe aie 50-12 Power Houses, ..:00a tecae 2 esa ee ate band Sant Ao eee © eee eae 40-11 Steameplants..<, oases cele scare ene er ome ecvaner et Seen Ga wap een a nt a coset 40-11 DUD=StAELONS. f5. 2:50. 5 scale concioa sos ePeva ate fo eatin eras ee eet a 40-11 Elevator iSpectOrs ssc diieatcci- net eee te 2 = oh atom a ee ee voce eae ote 13-7 Elevators: See Chapter 79, Index Summary Emergency exits: Those in addition to normal exits. . ... 0... 2... 2622-2 ee 64-6 Encroachment over property lines:— Balconies sci 5 -s.5.s02 ace Me bo are Bac ae eee orafoe ee eee 45-6 CanOples =..< «s/s did see ee reese «aaidaiem Roe a ee ee ee 45-6 COrmices:..0 ods ses eae ted ne Seem Site tos OL eee et eey: 61-94 67-56 Doors: General... 3c aces Seccercere ans tga oer gee es eee 64-18 Gl GENERAL INDEX Encroachment-Existing 21 Encroachment over property lines:—(Cont.) Doors:—(Cont.) INNES 56'S 65.6 5 ODIO DRO AB CCID ROU CTO CROTON Son et nC arr team 53-109 inesshieldestaitavestibUlemn: priuvcmrcrac cian irae eine sis ayer aisle ecisiae ojerslee 64-45 TPGWWERCENOINS J 5.6.6 Bee ade on BO OCD OGe De cIce oe Cena tec icine eee 7-2 Engineer, Structural, see Structural Engineer Pepidecrs Mepartment of Buildings. ...f. 5. ..c.e ce see ee eee ten ene 13-8 Entrance menimnerpalemDetnedier sss cana ccrs cers Seeks celta ores e's ai siers oe 40-1 See Chapter 53, Index Summary [BINA (DOWER Ole oo 5c Gol ACen nena alee orden OTiome not cee iain een oriole 39-3 Escalators :— /NGECRS Tho TRATES ari Oe eo ae neo Oo acne cineca on 79-146 alive, aon, SO” 27ers ieee a ea SOR e ele CeCe eo g 79-143 PAUMENUTEM MTT DE CLIO Merop sts See, ayaa ce 4, asco exe: exenditars aaed tia sper siete ene Oslo oe Maaceereee 46-11 Basement escalator: 100 ft. distant from upper floor escalator.......... 64-58 Business units:— Combustible materials permitted when stairs may be combustible. .. . 50-48 Bi RESSMIIPEESS BOUNCE CIAUSE'. «i524 oe. S200 eioie eg 05 ais Ais ohm ania. ST ele clos 50-48 Meualenummber WOtM GITECONS |... .. 0.05 6. ce ads pom a clasls wae womans 50-48 Nite OSUHERASHOIsStalrSreces oo cetiese ees cetera ovale eee en atari ee he See 64-58 limallasune means eo.c pele cote ain atone ice ne GS areroorarto ts coc 50-48 Qulbsininias ioe Ione henise ss peione oe boneoodscbooaese coe boos: 64-58 Construction :— Baleetraces, soliGlonceo comes secuebeo ub deawa dole adcdo dsacomaniacD oc 79-144 Rie tated Hen SMETETO VATE ae 8 kiana oss aie aiale 5 sis ieee ae Res orale outs Tavera 79-144 ILENE 5 oa 6 doth Be Stash 9 OCS RO OE eIS Henri nn Dra ance Gomme p Tio tc 79-145 Wer AP DUC MRE tote Sd ae daoalra AS a, nace orn: -.> vues aie evsi@t ers > aisinle uve seeee 79-146 Se ae EMIC ERD SP ae rss tees, wi crave no cle/n\ = lnvebe stole gie eiale a alt. shel miele stemeer 79-146 TED. 6 66 66 SER RES CE EEE ADA TEE cia SC ear aa anes GomcmT 79-145 WennedcsMovingsinclined| state... 2... .2 ce sce sels see ne Se ee 79-2 MIME MIGIVIGUAIMOLOTS....02 6 c's. eos wo case wlets ve eee eee newness 79-147 TPHGIG! GERIB, 6.6 o DENIC IIE GOD CIEE On ines Seo ar Oe OIG. torah OF 79-175 (Canal, ooo conde tt neta ob ote A an Dea On ee seer en ons. 79-143 INTGLOSUERASELOMS LAlnSer eerie ion ae orre sor orate: eivertacien 64-58 Imelosure required in‘business umits......... 22.2... 020ceeeceeeee eee: 50-48 Inclosure not required:— Non-required escalator, sprinklered building. ...................+-: 61-22 IBXCEP EWE USINESS UNIS apyeiet tle exclker sero erctsrs efo oi lara) aera one erent ater 50-48 BOB Eel OMe ey Fras aeaee kets echo eels aici ehe's Sr oNslayenepstenate at 3 charg eieiehts So tohenetoe 79-3 ARTE ESET UIT COs ces Sere aaes eteceseiel oi feyioue) cu ciens 6,10) 9 aiaiayere. 8 4)c\ sie) ate everMrenarene ts 43-15 aie eRe eT RL I OO roe eras Pavey ca) cin) ate) chalet a, chapr ese Toten: Su0) evn ever are dolotals e atenenekale 43-15 Hee MEN MISA E OS eects eg Noose aloes gicic apthinvs «Siok > uae saneiahs cleus cis ys teiwdstotomyl= 79-148 Safety requirements :— TRAIREE S. c.cin 0 oayORRO CLA ReREEIS IO Daid GRGID COTESIA. CERRINA te Clo. Cerna Ott 79-151 Brokenschainisate ty) GeviGm rier oi-leic1e)sicberateie ee ee si) eelF to tire 79-150 Biectricalphase Protection... 65... . sie cs eee een ce semn ee cs 79-152 Saxpareail CAG nit (= a (eae nn ten Rens See eben in ier rinie cis Onno or 79-149 PGCE CUB ON ETMOLS o eu rats ia Sm iate ss nrcl = ciate cathal nde nnsy ne > oes eum ero) ines amet ol 79-150 RPEEMICECE VICES ys rena 79-143 TBydiml SGN: 5-6 5 dors Maen ee A Oo. ua oes hts on Or 99-2 55-3 Existing Buildings:— Affidavits required before permit :— Givin pcos tiOl WORKc i. «2 \« '0.-. fe cisisle a6 oan bes ne meas iepls alamo 60-3 Giving estimated cost of new building.............---+---+eeeeeees 60-3 Required from architect or engineer... ......... 0. eee e ee eee e eens 60-3 Reqtired from CONtrACtOL. 6.564... 2 ce cca eee teem ne Sener tenes 60-3 Gl 22 Existing—Field House GENERAL INDEX Existing Buildings:—(Cont.) Athidavits required upon completion :— Giving. final:actual Gost.< ss, 2ci: «sacava sAivsrecla aes sess RUS hat ane Aa ee 60-3 No rebates, etc: given or recelved:: 3.2. 220mes. 0. ss sees ae 60-3 xcept As per Custom. 5 cep see reas «eis tre ests enn 60-3 Alterations, Repairs, and Replacements:— 50% cost limit, any period of 30 months... 6s<5.5.40i0.6004 a0 0 Ba ee 60-2 May be altered: asiperioldicodesa.. 2. .cm: asec neat en cere 60-2 Over 50% cost, must conform as new building. .................... 60-2 Hazardous use unit addition must conform........................ 60-2 Plans TEQuired ta macc meta cts sie yi eeeereee eRe I eres nereaee toe 60-3 Completion of buildings, in progress as of July 6, 1938. ............... 60-1 Converted: Must comply as new building............. 40-1 60-2 Defined: As in existence July 6, 1938... ...2s.. +2. us be eee ep tases 60-1 Exit lighting: Shall conform by July 13, 1939.....................0.. 66-1 Exits :— Inadequate because of alterations, etc.............. 0c cece cece eee 60-4 Inadequate under code under which built......................... 60-4 Must not be reduced or decreased below original code requirements. . . 60-4 Notice to owner to.abate:violationt=. ¢s.. 24.02 .ta25>. 5-052 eee 60-4 Shall be made to comply with new code.................0.00 ee eae 60-4 Theatres: Exits:not tobe reduced cA ghe ccc os cen ee eines oe 29-5 50% clause: Means 50% of cost of mew building...................... 60-2 Means present cost at present location.................0 0c eee eaee 60-2 Hazardous WS) UNItS). eaecke ceecscs cst o acne ete abet sncea celine 51-47 See also Frontage Consents Films :— EXGELATENCEIUOS CHE MENG ore ta LaCie eee Pe ae ea aa ees 53-161 ENTE PROOICA MINE ES Hy Mey iee ae, octane alec Ss cintene ENN PNG Ss oid sigisliows Stace aos 51-79 Edlemantaa a DLeMeMNIINS CUEUEIONS lne-sene eno ee ee 61-62d In all other locations:— Except: In common vestibule or stair shaft. ..0..7,2..0004 2+ o2.08 6 69-11 Single fire door in common vestibule or shaft..............-----26: 69-11 Glass prohibited. .....,. 5.066 secees oe 69-19 69-20 69-21 Except: 144 sq. in. wire glass, vertical shaft, 45 min. doors.......... 69-21 Gl GENERAL INDEX / Fire Doors 25 Fire Doors:—(Cont.) Wabelsionvallifire doors, testing laboratory....5...2.20-0...+--+: e503 69-3 Waboratonyatest req UinementSi 9555.0 ss Oana c as cksasaaseosseosaras 69-3 to 69-8 ocksitoropen)tromunside without key. <2... 5.. sn04--2e0cese essen 69-26 ighourconstruction requires 45 min. door: .-:.....se25.«.+.+:+-+e2-% 69-15 Openings, other than doors, same fire resistance........ 61-62d 69-23 iBxcepesprinklered | ducts OF INGlOSUTESm we1qe 5 eee cannes +s 6 ese ee ns 69-23 BEOLCCLeGeapaInstyinny UisyAdsia os cisiccsers eins ore he eroie eras ae Oe Os eye eieisls 69-28 Required types:— 4 hr. construction requires double standard fire doors between oc- GUD AINGIOS peeetetre cares Seder ease twice oieam estou geese teh eye le faim 4 audi aayanes esos 69-12 4 hr. construction requires single standard fire doors xcept Between occupancies (as above)... .........s+.200-+-6- 69-12 Syarconustruction requires 60min. doors... ..2...5-2-+--.s-0++-0-- 69-13 xcepi+onmin-doorsin 3 hr. vertical’shafts: 3...2.-.+-----o.42- 69-13 Peinaconstruction requires|45 min. door.......-..2.....++%-se+-s0: 69-14 iGirsconstruction requires 45 mini door. .)......-.-.5--se +12 e ae: 69-15 Rolling steel shutters:— OMT PE CEASKEXTES em cere ne a arch Tee coal ne fern ete sel este Sane 69-26 Saigiiy CEWIGES os Se are ane oie ae nee oe enon coo mare cod nict ce 69-19 INDE o o 0 0 oo 8.0 GOT RE Cee te ese cate its fe 69-19 See Occupancy, Chapters 47-58, Index Selslots torclose withiopening door. .... 2... ....5--+ 62 esses eee neeeese 69-28 60 minute doors:— Closedipositiontto: be normal position. ... 2... -a.02s+sss++ yes ase: 69-20 Bramestas required by Sec, 69-17 and 69-18. ......--....2..5-.5-5- 69-20 sama STOLOUIDICCG sy. ccmas fis < citisie 14/5 os area, Paieve,s +o NOE 69-20 CES ii eric Pare ee cee era ers cn oa fare nee OR eee ec 69-20 IBID IRC TURD 5 6 <6.o tie. Behctotes OAR Cree cca icy rane re Sm re 69-20 lptineal cloopgsigete(bbbeevel > oioie pale BO DOIG Bee oe coomimeeman cnn. cer 69-20 ibxceptreleyator hatchwav doors)... 22 sarees s aed aeons 69-20 foUsopermeme point, fusible ink... ... << .cleses soem saa oer 69-20 MGmnalhyatorbetia ClOSed POSITION... ..:..<4 «2 Some age secs sen eer 69-20 Chcimnilings clare cos oe aera aoe eerie shoe ole eeeh eae amare 69-20 Sillsriserequined by sec 69-17 and) 69-18) jc ccsis ss sna on ees oe 69-20 INES RES TUTENTMNISs 65 Gonanenonvoedounaononasu0euuc 69-6 69-8 oes: lalallonpitteell ees onde abet cee meee CRE OUr ere acabons 69-20 SIN GETE TASTES Gera taro Otho Gs Ole cal I Ono cree mon ne en eaar etre Ph ence eres 69-20 ‘SUES! (OI tere, SStoere uc eao cece eR NO hme iene ite Chor cemcrecoke creas poy carr 69-20 Min-cladaS-pliyawOOd COneses 6 set. > tel ayee om aie acusecsei Sees eras 69-20 Weneerpenmitteds: inser txs scene 6 ae de eee 69-17 69-31 XCep ts ONistecliplateldoorsmmccmac cmc ce oer rite 69-17 Sizesminaxeusce Mable ©9225 204. cisasc goose emis SoG mene aes Seni Ses 69-25 Standard fire doors:— Nan gedatonpe ningeds roll or sliGe.: «+= ase 5-e cna 69-19 Except Rollin eisteelishuttersiss sects emer eerie 69-19 Construction: Frames. 69-19 69-17 69-18 69-20 (Glass jana) dlyinels siiclaotc coe comes oe cUutadoadso pacacame nto Gem cme 69-19 EVA CW AT Cry steeies Se iG chong esis eh ete eae eemaysdetay GHG Mace Ge are hse remedies 69-19 Bap rainenwihen no tramesa.,-. eciae oriirrne some naa ae 69-19 IMIS noon Sine ced et ERO oor Eo Die clony Centre a citer 69-17 69-22 Omoperatingapoint, fusible limice. «es eomets oe seen sere erate 69-19 Oneratineyd 6viCESs yo cco crs eee eT oe ee eae tenes 69-19 SHS... oc 3g Sos a oe aoe OR roe cmt 69-19 69-18 My pessollowsmetall sas)... <.ti- ace cere eee lent eee ermine 69-19 Rollingusteeli shuttersis.. cis. croccee tein tae euckoae stele ie minke a aredae cnet 69-19 Slee terme Fall yearns eiexiee suse: sie cuore eee Money ao echo aso ee Sore iaucteyt eee 69-19 SHGEI (DV ETWD Fe Cuero ORR Romane rerio bie Sciccie Hols share mace ore mer orion 69-19 Iti Glkval, Sol ite vQorekto) eigoboGedousue Goburwoe sos do aa alo lore 69-19 Weneer permitted: asin... - aero ae elaeie tes 69-17 69-31 xcept OnistecliplateidOOrsy] ee eee ere rs eit erate 69-17 Stan dan GerestSpeyeemen es, cocci se ae CRE ie scree as Pataca Sine ee 69-8 Steel plate doors....... 69-17 69-20 69-21 69-22 SWOT MTMTSS lOy7 HD WEE Cie gs Gao coos ce cadcoaed se obocubeuonuensanee 69-30 Swinging doors required :— OO) Darin, GOSS. os aie Pee ae de bicchs ce NG Od OO ER eer at are ora oi are 69-20 Gl 26 Fire Doors-Fire Escapes GENERAL INDEX Fire Doors:—(Cont.) Swinging doors required :—(Cont.) AS MIN; COOLS s slat hadace ayes aie 4h fees Skea Oe ne Oe 69-21 Except: In elevator hatchways......55.4.2..¢203..6-% 69-20 69-21 Tests made by qualified laboratory... 2: s. aces oases te oe oe eee 69-9 3 hour construction requires 6Oimin. door... ...3:.:e000 08005. oe 69-13 Except: 45 min. door allowed, vertical shafts..................0000- 69-13 2 hour construction requires 45 min. door... « «. .sinma ves ete e heer 69-14 Type of door determined by:— Required fire resistive valuerof partition ..22.22 24.0. 24.den2- os eee 69-10 Required fire resistance value of wall... i...%... 22400 .<,ve enh Heigetoee 69-10 Veneer permitted, pin tac ae nee eee Cae a eee 69-17 69-31 Except: On steel plate doors:s.:.00.0.0..4.0 0a dace cee s ada e eee eee 69-17 Fire Escapes :— Alarm system: See Electrical Codes. 2 aa: 220s -5- ote le eee 88-104 Chutety peices... Geiss oe eae tee cle ere eee rene 53-107 64-71 to 64-76 Exposed metal structures. =. .<.4: 25 ss.0-¢ae ee. oe cues ene eee 58-87 to 58-90 Waddertype eh oo esc ce ae vena ee crak be oe ge tele: nee 64-77 to 64-79 Stairwaysi— 5. eens cars fa atse es a oetonle He see ee ee Cece see eee 64-59 to 64-70 See also items following below Fire Escapes: Ladders :— Access to roof: Buildings 3 stories or less. .. 5. . ss.0n.02 3 panelew se eoe 64-11 Counterbalance requiredis =. rca: g 2c. ces sa cc ne safes Hes Ss ee 64-79 Counterbalances: Width, same as ladder....................00000008 64-79 Defined: Slope over 45° from horizontal................... eee e neces 64-77 Hollow sections prohibitediy ..02 1a 2.3) anne eae ee ae ee eee 64-78 Pipe sections: prohibited)... 2.4. one sees eee ees = eer ee ere 64-78 Rings: max. (4 in on Centers: 0... ec es oe ee eee 64-78 Wad thi-smtri ad 7 in: Se..8 2 a. ops fovee ests cecnene Sete eee ace ee 64-78 Fire Escapes: Stairways:— Access required :— Casement window, 2 ft. X 6 ft. 6im. min..................000 02 ee 64-63 Door, 2: tt. Ott. Olm, mines Ss... 2 Hae ee tee ae ee ae ee eee 64-63 Door to open from inside without key................ 000. eeeeecee 64-63 Sill) without stair;.2 ft; max: above floor.:... 00.2 ns.02.ce5eat tenes 64-63 Stair to sill, as wide as door or window............... 000s eee eeeee 64-63 Window to open from inside without key......................00-5 64-63 Balconies: Construction. cers see aies seers oe ae ea eiiees 64-64 ength.sminy Sits etree oe eae ieee eee are 64-64 Obstructions prohibited. = wo. ecm tet Seance ee eee 64-604 Same widthvasistairs s,m. 0 sees reverses crocs © rice ete eee oe eee 64-64 Clearances :— General: Min. 14 ft., over alley, street, etc... ....5...0s 0 ese ewee: 64-69 Theatres: Min. 14 ft. above alley... 0.64.00 000 ste ensue bw seme 53-80 Min,712 ft; above sidwalk 2.2.27 ---4 550.55 ee el ee 53-80 Common to 2 fire areas, with door or window access...............+5- 64-62 Construction :— Anchors and braces ij ocx (n8.0 os Ge ee ee ec ee cee ees Ae oe ae 64-66 Balconies; landings; runways. 20. oes. 2 eek on eres oe ee 64-66 CouriterbalancéSitrnat sc eats Accs ce pe ee ene ee ne eee 64-68 DUELIN GELS oe ee sere eres ce ee SO ee cies ER ep eae terete 64-67 Three railsirequired..is. 2... oe oc sacks s pos er eee eee 64-67 Counterbalances :— Permitted for bottom flights only... <2... 2s.ce cee yee eee 64-68 Prohibited: in ‘theatre exit courtss....5 2.025... 2 sen seer ae ene 53-80 Vertical height: Max. 14 ft., top to bottom landing................. 64-68 Cut, min: ON... 4.400 2h ak ie eae ce cine PEO. So a oer 64-65 Department stores, fire escape stairs prohibited........ 64-60 64-59 to 64-70 Doorss45 min required’. (225-0. oa.c anes ess ss cs hee eee eee eee 69-16 Exit tostreet at grade, unobstructed..o.% ¢4.4. 2. soe crea eines eee 64-62 Exterior stairs to be same as Fire Escape stairs... ..@2 0... 205-60 - eee 64-59 Flights may be'separated. wn. 2. asc3- ect ee se tates Cor eee 64-63 TFL AM GATS 8S «co safe ore. aya Ty Pees cece oe ae pe STORER ee a 58-17 Hospital: Platforms to be solid, non-combustible..................-.-. 64-64 Location :-— Common: to 2fire areas 4G tnacaee eee oe ee eee 64-62 Gl GENERAL INDEX Fire Escapes—Fireplaces Di Fire Escapes: Stairways:—(Cont.) Location :—(Cont.) On alley, street, or court, or other open space 10 ft. wide............ To lead to public alley or street at grade:— OVC iy Ol s oad do's oloigs aero Gee teak arene clei Cie cic One ee Byauunnel2shraconstruction® 7 ft. higchyonas....5.-...5.-.--.0-- Byauunne awa lerastexd trey omak ion See eels eek: coos dda cote Metaltshieldirequined overswindows, €tG)y...4)-.009s+.2-6+-2-2.--+-- Multiple dwellings: 4 ft. Fire Escape, not obstructions................ Renmitted-sbusiness units, under 264 ft. level..................-.--+- On other buildings as per Occupancy Chapters..................... Overstreet linesnetheatressgy se ee recere sae ioe: occisee eee Cher Alles? 3 5.a-etbd teks lola Aneto ene one ere Rane Sra Tee cls peer hh ne Piamsmequired, when over 24 in. wide.........0. 22. cece see eee cles Prohibited Above 264 ft. level, business units.....................-- ON GraS ULC tlm Copernic cehhie «Si acl cel cashine, Sestiapi Fes visneouna oe Excepiemuheatresy allowed). wv.s.< esac discos pues vom sue eeanee Erovectioniover, street liné prohibited’... .....¢..0.0502 go. e so dse one AX CeD eMUMCMeAtKes pte tf sie 38.24 Fis Sp site aus ose Mevunsie 4 socconsens operas Kisemmaxeronmestreads 1Ohime min. 452 aa. sce cumes cose a ova sci eeie SHBIDUES , 5 0 > 0.0 GO Este Oe RE RRO ean eet nea ree AE ts nn Substitute for interior stairs :— perm Occipancy, Chapters 4/—98.. ..25...+-oneeoess onset see cae: 1 Fire Escape in lieu of 1 of 3 stairs in bldgs. 3 stories or less........ IMayenotereplaceifire-shield’staire’. 2 ...-5...4+e see seek a edeacee Wadthesame asistairs replaced—at least..........:5...--000-+0000% See Occupancy Chapters 47 to 58, Index Summary TEMES BEES co 9 Ub cS SNe oN ae ae eg errr Tunnel exit from courts:— Meigs oighesamenwidthyasiexdt. . so: osc. «os ccs s sacidcacr ~ eae eee Doompeateor other closure prohibited. ....0.5. 0245-22. ..205000006 \aWivaliling Ons” 2240 St nee ee oe oem ee ale Peete Windows, Type A required :— [ocated within’ 10ft. of Fire Escape.............:.-. 64-70 Pagscal joy? [hiney OSC ey pean ones Soe Meee dena mee cone boono ona. Fire extinguishers :—-53-177 49-39 5 ' 63-9 54-70 55-9 Fire Limits Mlownines |sarllehtnvuse go euapeenddeocuodopouobeceepanos: 43-17 Provisional fire limits :— ID SHINE so 6 to Mame aU RIO ODE SORE BaD ne car ame AOA nea amtes yore fer Brame buildings permitted... =e... 60-420 24 RE tITIOMPOTACONSEMUS., suse foncieie cece spear itials cree he, acetate toro ork ee SqMaresconsents meq wired around sane qe eran aeerereriere eee errr IB SxeG Hes ING Cones iAe (UA oan ooo wo nopocoUMagadoorercanonoue Fireplaces, Domestic :— Chimmeysconstruction same asin Chapter /65..- 4.24... +s aes Clim ygrecuine cl. SA sus) ron) d arerel ome eechaeres a oes cyereroyel eat very Sette eee Defined, not including commercial or manufacturing uses.............. Flues: Area, min. 1/10th fireplace recess opening..................... Construction, sameasin Chapters/O.naeeas eee eee esi Dampersimot to obstruct open tluetareany..)- pase sei. es anew re Dampers not to obstruct required open flue area................... Sone Over 457 jyrolahl opweael Penns oobnico one bodes do moedbaok soannon dt Hearths, construction :— Al Gal, sonlims (HoNcld Ack eee ORAM. 3. SIA Oc cana non eee eRte aot nr eck 17) To), TAN GAVE) 01 EKA LENCay? Go ONO Os oo ooo dcobeuwPagoudobea Aus oaoL AXQ) Tom, LaMUvaL,,. MOVIN NEKO? ClabbadaN/, 5 eo4 oop oonoHon bu bnaue od sno bne. Supports. dieproolsslabvon bricklarchesmee ees ele eee ei Woodatrimmienarches to be removed). + sie 2. yen s cree ee ee ieee ‘WerORES 100) LOS Grn Coane line, 5 ooo scccnccecdoucsedoucuescodauunouauc Walls Sims mun’. thickness, if/solid) bummed clay.....-.....2¢-...<..- 64-62 64-62 64-62 64-62 64-70 48-11 64-60 64-60 64-62 64-62 45-13 64-00 64-62 64-62 64-62 64-62 64-65 58-40 64-61 64-61 64-61 64-61 53-80 64-62 64-62 64-65 64-61 65-4¢ 64-70 51-127 57-79 89-2 89-1 89-4 60-5 89-1 89-1 89-1 89-1 47-4 61-100 61-96 61-95 61-99 61-99 61-99 61-99 61-99 61-97 61-97 61-97 61-97 61-97 61-99 61-98 Gl 28 Fireplaces—Fireproof GENERAL INDEX Fireplaces, Domestic:—(Cont.) Walls:—(Cont.) 12\in. min. thickness of other wnits....: <.0 «2<)Soct eu see ee ee eee 61-98 Lining, firebrick, castiron, soapstone, €tc....... so. .01 00. 006+. sone 61-98 41n. firebrick counts in,wall thickness. .. 2..... 62 sc-aecrs Soom CEE 61-98 Fire Prevention See Sec. 59-17 and 90-27 Excelsior Sawdust Hay Shavings Hemp Sisal Jute Straw Lumber (or boxes, etc.) Fire Prevention Department :— Plan approval required as per Sec. 12-24 for:— Business units, 1 or 2 stories, over 4,000 sq. ft. Business units 3 stories or more Churches Garages, Class I Hazardous use units Institutional buildings Multiple dwellings over 6 dwellings Open air assembly units Public assembly units Schools Theatres Other buildings over 4,000 sq. ft. Other structures over 4,000 sq. ft. Fireproof Construction Requirements:— Area dumitationsiect. sake esis es = ssc eee ee eee ee ee ee 62-7 62-8 Combustible materials, allowed, certain uses......................... 67-20 Exterior inclosing walls\...23,:.dinhs oes aes eee orn ee eee sae 67-15 to 67-17 Facing materials of masonry, 3$ in min. :— Hiffective only iors firéproonneg:.,...) 0-2-2. 2 ee ie 68-32 Concrete cast-in-place, wire around steel... -...........-002+eteres 68-32 Coverings: Ducts allowed on tops of flanges................-.--+5- 68-36 Miers | prohibited im COVETINGS.2 ors 5 senile cs om ein el vin she iy on 68-36 Pinesiallowed on tops of flanges << 27. cei. = seis cis es = = xs eiine= 68-36 Pipes PLOW bIted IM. COVEMMIR =o. mets ism een alesis oie oun im oie ciel os 68-36 Ducts prompted i COVEN? jcc). cree eye weit oa eee +o oe a 68-36 Except. Allowedion tops of flanges... 03s wesc cans ne oe 68-36 Fireproofing omitted: Heavy Timber construction. ..............5.5 67-40a See also Occupancy Chapters 47-58 Blanges under 4 an: Covering 1} im: min... 0... +--+ tee e+e 68-34 Gypsum units:— Attached: By fabricated flange reinforcement.............-.-.++: 68-32 BS ypEVe UAINGLEINS |, otece «cx -cese OUI e EEN eA ha Sieg) Hiei 8) ays eka re Fiend oats ee 68-32 By ZOULSIGeMehWITES = cia teen iese estos or eieerremas gery veiers se 68-32 Prohibited: For exterior wallsmembers. 23-8 «22... 6cc- ones eee s = 68-13 Gl 30 Fire Resistive—Fire Shield GENERAL INDEX Fire Resistive Construction :—(Cont.) Fireproofing of structural members:—(Cont.) Gypsum units:—(Cont.) Prohibited for members below grade..................... 0000 Except: Ceilings part of floor'system.c.. 0.4... gece ¢ Sener Lintels, loose, unprotected :— 3% ft. max. opening: Fireproof construction .......... 2... J. «seer Semi-fireproof construction..< 4.2.0.4 . desc sae ae eee ee Supporting 1 story only: Heavy Timber construction............. With unprotected shelf angles: Fireproof construction............. Semi-fireproof construction (See also, Lintels, General Index)... . Masonry units: Well bonded and anchored :— 1 By metalichips.s... a cc-isie secu oc ote sen acts seers eee cee 2s:By Outside tle WIKES< <6 ccc se ene ee rie 5 on eee 3. By shape Of Unite. 2's ore ne ag ve Soto ewes conic taal Se ee 4. By wall ties of corrugated metal ....¢... .20.005%e0ee Gannon Mortar: No: 3 or No. 4 to be used. .... 5 o. n24 con o% cos Sea omer: Except with gypsum: Use 1 gypsum, 3 sand... : ..2 2. 2s as sate esc Trusses: Bedded solid around members...........0.. 0.0.00 eeeeees BATE, CESES(.. 2.5 ides oat ae ae Red Arnal laa nie Aone ln ae ee Floors: A“Nhour CONSUMUICHIONS, 2 Merve sees Hoe See tenes fo eae 3 hour: ConStructiGns wi... vac dacs a eihaes s stecvelscsere eis eee cst ae 2 Hour ConstructiODy cs .qs sitsin scape tes ees oak eae ee cee i Jhour ‘Constructions. orc ai cictc. oe ose Oe ae oe ene ee ee Metal members, protective covering :— 4 hour construction... 1...c seer «se talk oe ee ee eee ee 3) Dour COnStructione a. ct.ce. ee oe yet e hoe eee ee ee 2 HOur Construction: sca cane nes oo Oe ec eee 1 hour \Gonstruction.....;4.c.toan een se ee ee eee eee ene See Fireproofing of Structural Members, above Partitions: A HOUT. CONStEUCHOM:.. 56 c-s2 cen hee oe Aime ora eee Si DOUL COMSETUCHIONS: 2.5. Sals.% oer caerer eee eee eee 2 HOUT CONSERUGEION cs cee er eter ae anne en Ll hour Construction «aus 65s sto eens eee herrea stave Uae Re Roofs: A hour .Constructionia. «se. 42.6 sa neces 2 cee eeleis Beb no eons Suhour Construction, -ar...6). ts oso Moet etnies | eee ee een eae 2 hour Construction. «22 sees wae sen Cs oe os he eee eee lehOur.COnStructiony...s6 pee aon: Hee ee eee Walls: # hotir Construction sane eee ean osc oes see eee eee 3 hour construction. <3. cence ces ecleereieoe sucess dee Bee 2 hour- construction. 2. cers... eosin oc ae ee ae ee {hour construction. 22). - mass ee © oe ee one eee ee ae Oe Fire Separations :— Assembly. rooms. «<< o..d:0s 0 sigs ieacs eae 55-14 29x25 |D7cichalh (0) sno ee nee ee reer Mere erin nmrnr Se st ar cot ptic.c odor Masonry.:12:1n\. miners detec scm ge oes « ce be oe ee Om eioe eects Multiple occupancy: 2... «+ sci: sale saris sat St Sica Re mete ae emcee QOFES CUS Joss nates: oles. a-e eters 4chivass See Sos ean © Dine 012 Shit REE ae ee Openings. ¢quivalent.to:double fire door ..... 02a: sskieqe eke asec Reinforced concrete: 8 im. Solid@min..; «2. oc.u0. coeaet ne ae. easera aero 64-51 SCHOOIS|3 arsicze oe.ai2 olan does, fs Lolen Move, cis Rletmennee eo cenene Rete ener ne Reames 64-51 PH CAETES Sco 25S caevasss cs eee oysters ep nckeee ater tots eae ele reeeeteie a eoretone 64-51 2 4ft. Fire shield stairs equals 3 interior stairs....................- 64-51 1 in. Fire Shield equals 13 in. other stairs... oo. ce.2 ees essa see aes 64-51 Combined with 2 other imterior Stairs)... .de60-5--2 sees oe snees 64-51 Location, business units:— 100 ft. max., stair door to end of corridor.........236.<200e004 08% 64-51 see also Business: Unitsieia sacs «se sie ee oes Shee oa as Sere 50-36 Terminate only at maim exit level sacs once eee see 61-9 Frontage: Footage required: See under specific type of required consent . Fronting on another street, buildings not counted.................... 59-1 Miowanrctiramesbuildings es eccmea tactician icra eteeca ae Meera ee ree te 43-17 Rendlitessn25\O0ktomp200!00)a-ra ner nnienaar nn ecieitnie er ae ene 59-22 Rermitissuedionly, after consentsjaremiled!s.....2.4+.- e252 csceen+ ss 4--- 59-2 Rrocest signed by 10/or more property Owners.........2-----sess-54- 59-4 Protest signed by majority, total owners under 20.................... 59-4 ubicghwearin gsatver protestant acre cee cee ac oo eines 59-4 equine dEbelore;perinltis ISSUCG aera ci cien cieie cee cir 59-2 Required for certain uses: When half of bldgs. in block are used as residences................. 59-5 Ormwithines Otormsuchistreet incre mimicioe case coeie one ne a moeie cle 59-5 SCUALCRG ee Cemeey sob cic cabs.) Eee ee Oke oaanct racials. eee 59-4 SLOLesm Ate lined Mets: spar oa ccissiars Cease arene ne Genres ae als mainte 59-3 Uses requiring frontage consents: AMIS SINUS 6 goon booeragdOe bo bc wns 104-7 59-7 59-5 JANUS) TROL AaY0) Dyes cs ose MEAG Gee RO. -65S 315,00 da Od coon Een OO OORENE cos 59-13 PATIL QESALES OOM (ore che 5-55 eae Po ce AUTOR oc Pos Te FS Pees RE ee 59-14 Billboardsyandasienboardse muse) eer errerr iim aioe aeicieroer rane 59-19 Bowlin calle yas at eat Soy ote torn: Grace eine hrc oo aisvadianne 111-5 BUH. oso Gap ee ee Boo ROn EOS § Gon Ube Oe ee oe Er ere ene 59-3 (Coon iio. o-oins Balas CR EER eo Oe SER Bes Oe Rene Sena ee eee 172-5 38 Frontage Consents—Grade GENERAL INDEX Frontage Consents:—(Cont.) Uses requiring frontage consents:—(Cont.) Billing Stattlorieeasencge ects shee cle oa. eee eae 59-8 127-5 Flammable liquid tanks\...2i.%). ..¢ soe ce etre ere eats 59-8 Garages: General................... 59-9 59-13 59-14 Private (Old Code No. 3249) General detailed list of uses. ..59-14 59-1 59-2 59-9 59-12 es ren eee er ee er 102-2 102-8 (Grandstands\<<.b.a. sac. tetas ee oe oir 59-21 59-20 ELOMIE SA se antl, A Sees sisebess abate tens oe oA OS eee e TE et ee 59-10 Hospital’, 2th. cte es 2o:sonnapoesneicie ees enc 8 Orta ono yes Sera eee 59-11 Holo 1 Cho Cee ea rer eee neers ere Pen Teer ees kr raat d. < . 59-12 Junkvardror Sitetjcgsc sae sae eters acres arn den eer een 143-6 Ibamiber *yardS eis, 2e2 .c sayeel aera sere oe ee 149-4 149-5 Open shelternsSheds 25 cca. «se eens sie ate tee Pe eee 59-16 Private garage (Old Code 3249) Provisions, Selling Of.) 280. acct: ae anise ee ee nine re eet eee ee 59-6 ReLOrMILOTIES: ghee osasvn ele es kedhe cee Coens etree eee 59-15 Sawdust Storage ws ee seh oie eee ee eee 90-27 59-17 Shavings SLOTAGE. eer sans acscis.y says pes ame ie ee 90-27 59-17 Sheds #shelter oo sie castes siecle dun Dee cies cocker ee eee eae 59-16 Sheltering Institutions...<.< ss. fesse occc.o s eisreneva tear ve eietess chose cea eee 59-15 Shelter Sheds << Ga:s.c4.< vuiin so eas siean oan ee a eee Re en 59-16 LADS siaceene, seein cose b.alenn 5, EMS > oD eg ooh 59-18 Storage: Excelsior? ick ck boa tind ann cas fou bles once 90-27 59-17 DAW US Ei cra yo. i arienebasotansysvcidhv out fnentl vom eyteriseaenen eee eer 90-27 59-17 Say G'S rears erat aah taka ethic tee aed so. hoe ee ee 90-27 59-17 StOLG 350.4 cris AS vos A ee civiegs een varied MON yee eee ee aera 59-3 Tanks tor flammable liquids. «2c s.cakir eee se eee. en eee eee dates 59-8 Undertaking establishiients<,..45,023 «cua cpet ene ce eee eee ee 181-3 Funeral Homes :— Bromtare COnSeMte. ci..3-asu aes lee ne ee ee rae: 181-3 Grenerals cas cwrat Reel ce cipa tds Sale eee a ae ee ee ee 99=2 Furnaces, See Heating Plants Furniture Storage :— AMAT Cale nGs tae, DA oak eM ae Hone ce RR toe mee nk ee, ee ne eae 50-50 CORN CE IM tie, sac, c heaey secs dH he che ee 50-50 Galleries; «defined ...2 cee «oes ee see oe ee 55-3 Game ROOMS\. .lsc as. dN Ss wpertniccoreenseeo te ARC ee I acne ee Se DO>2 Garage, See Chapter 52, Index Summary Gas IBUIMersss soe neste earths sens tte eT tak 2 ws sh ee ee 80-24 Gas Plants:— Anmuall Imspectionusi 5 aden. hare earths oc ok el ace een ee 40-42 46-43 Buildings 92 eles eee 61-84 Boiler room separations: Pressure over 10 lb.:— 1 hr. separating construction required..................-022-e20e- 61-84 Except: 2 hr. construction required :— 1: Public assemibly/unitsi3 ee ce teats «eee eure Gree ave aueceete carrera 61-84 2 AUHCALTES 752 spss io hector aon ee ee aa rae 61-84 Boilers :— A:S:M-E., 1937 Boiler Code@ 2. y 22a. 26 ous pene oees eyes eee 80-25 Definitions :— High pressure boiler: Over 15 lb.:— 1s Miniature pollersty tees. dee cies eee See eee 84-2 2., Other high pressure boilers; 20 .....006 + aes co + cyclen 84-2 Low pressure boiler: Not over 15: Ib...2.25.. 6252425 eae ees 84-2 See Chap. 84 SPOS ES csi ge eaves AES ace Sire one wy aya SORT eS e 84-6 84-7 Breechings: See Smoke Pipes, below Chimneys: See General Index Clearance :— General: Asim table. nan se acdsce came ee eee ee eee ee 80-4 Ducts: Inside temperature over 250°... .........0 cece cece cee eees 80-26 Furnaces, wart aif...:....9. 000-22 80-17 80-18 80-19 Construction as per A.S.M.E. Boiler Code, 1937..................... 80-25 Covering of horizontal pipes in any 1 story:— Nay be com Dlustiple. ¢ 6079 aca seo 6 eases eee oe eee ee ee 80-27 Except: Fumace:piping nese. ccasae eens ees a eh ane sehen 80-27 Covering of vertical pipes in shafts 50 feet. high:— Must be non-combustible: 7.;.,c.8h,. ance oe cee ise ee epee 80-27 Except: Suriace, Covering: siu.s ease eee onesie See eeeeeee 80-27 Defined: Production of heat by fuel combustion...................... 80-2 Department for Inspection of Steam Boilers........... 43-14 84-1 85-1 Dry cleaning buildings: Firewall separations (See Chap. 51, Summary). . 51-105 Ducts: from hoods, overranges.- 2 = sees. a: ence 4 os. oe cee eee omen 80-11 Ducts with inside temperature over 250° F.:— Clearance 1 in. from combustible materials.......................- 80-26 Metal collars required through floors, ceilings, etc................... 80-26 Fees for inspection :— General f., 2-35 Sere ae et ee ee 43-35 43-36 IAMS sete ati aa eee carey 43-35 84-5 Blues, see. Smoke: Pipes belowWas...:22005-- 6-6-2 2 2 nee ties Serine Foundations: Boiler temperature up to 300° F.:— Foundations On soll’: apace none atoms 2 ace eee aa 80-5a Non-combustible Bloons «sz .haeen dct ee ai ord, oo ane eral pets s aveeia ere store oats 80-5c Non-combustible supports, with:— 4 in. clearance between bottom and floor, and Open on at. least-3" sides: a2 ac Areca sa crocs eee ie Se 80—5d Standard furnace foundation... ......6..20. 0000's = 80-8 80-5b Foundations: Boiler temperature 301° to 800° F.:— Foundations’ on Soils secvsnccsees, 3 acanstaee oe alee ee et eee nee 80-6a Non-combustible floors 2c. ae + oa c,cece es Sree eel Recee 80-6c Non-combustible supports with:— 22 in. clearance between bottom and floor, and Open on all’sides fez. 2s ae oars ay se sietetee es ee eae ee ee eden ea 80-6d Standard furnace foundation... |..=.. 06-2 58e 2+ eee 80-6b 80-8 Foundations: Boiler temperature over 800° F.:— Foundations onsoil.oo3 can cee ow a oon te Se ee ee 2 ee 80-7a Non-combustible floor. s. acc oo es tee ee ee ee 80-7b Non-combustible supports with :— 22 in. clearance between bottom and floor, and Open: on all sidés. f2 260 ie. sdcns css.e shine ard ee ee 80-7c Standard furnace foundation and non-combustible floor............. 80-7b Gl GENERAL INDEX Heating Plants 41 Heating Plants:—(Cont.) Furnaces, warm air:— GasmoseViasonnyegeun mee sale setie sei ePacres ame ee oo ew lvno eh oot 80-16 Masonnyaaumetaluibonnet allowediua-.cc sce cee ee ses sue nc so: 80-16 IMctalee2 Ohcrorabebtetarmiesmicren einstein saan a oda eens 80-15 Top protection, metal shield :— Extencin cel Svineibeyondscasinganaane. cask wee la cases. sae 80-16 Deiiien DD CLOWAW OOGC WORK: eras) a ciccis heteeareeee Sietaccl =. Geis erst olave ave 80-16 (DFM KOM Ceiling... aes se aes ee at ee ee 80-16 Clearances-seantitions andswallls sis sea. da. - ase sees ee sc oe ne 80-4 INE pISterseeagnemON=COMDUSEIDIE 1. site nee ciate mses ese sists oiene ss 80-18 Adams aia pipesre tay ores: (mat ic. SAPO eR ee tint sala ARAN 80-17 NATIT BAITES LACKS eecing. there setts sch Pare Seen ee ee vss ne seston arate ee 80-17 Coldfainducts tobemnon=combustible. .. ..2).0. 0. 402. ce eee ee anes 80-19 excep ipl siomtesinpleidwellings ya... 08 sess essence sane oan 80-19 Covering: Warm air pipes and stacks:— Asbestos paper, 12 lb. per 100 sq. ft.:— iichiee in. clearance to wood, et@)....... foc aagaen oon s <4 shoes 80-17 Or Double Wallsta asin DEtweeneresr rts yteceachs tay caterer nr eae 80-17 INBBSc. 6 v0.0 Seether aoe nen TNO eee nena cee eee ee ee Ce 43-35 Inclosure required :— INT oiiigy A CASUIN GS Srctey cet vores ree eve iene wend Siskes oi aeoues aes SRN Sapa GENS ae 80-16 Ileal CASTNES 35% crmichay yO HOE chee Le Oe ME IE iDs Onis Cece Sse er rere 80-15 BCEEMIES Application WIth Plans... ec... cc we nee woe cg eerste Hae cle « 45-15 Recitiineal 5.4.0 eaR ten oem Sone. heb SERS Orn nec Coe oo ete Eeticen 43-22 Epes. Clearances invthrough walls... 300 ss nse ee snes oases 80-17 Contactiwithiwoodetc:, prohibited. << .5 ss. 2.5.50 qeecaneeas aa: 80-17 (COMEMING » 35'S, 8 oe UO Cie Gl EDO EE ate OE ve REA inte) biel ices eens bases 80-17 Opening spnuiloors sdustitighitya sry 1a soe erro c oeieeerehoci ere ceteer ce 80-17 Cie iromeiurnace before inclosure..0 2.5.0 25-5 seston o4- os eae 80-17 dihicknessrotsmetalirequiredermy-e se eee oo oa eee ee 80-17 Maing REGIE s 5%, Gees eee COE DRO See cone Maree eee 45-15 Negisters2.n. non-combustible border... ..... fe 6 es0s.cnesss sees: 80-18 Singlemasnestosypapenicovenne saeco aeons acces aoe 80-18 Singles 2insawaye trom wood), Ctr... ....04:c.5. 005 snsss eee ee 80-18 MII CKMESSKOM PID Carte sol erates osipierss aiaT tam etseee andor eee ra 80-17 Stacks, same as Pipes, which see SIRTIRES,, S/EDET A ATO) aR ae stm Be cir ete deer eae ead barat es UE ce 52-16 Casibumers to haveautomatic: shut off... 5540. ons sss.es uh tions e ee 80-24 IREVARC OWS WES ULMs os ooo5onabenopnbousnaeconeannee 51-109 80-8 JEIOOGE OWer TeMayaS, IA, Cues. conaodnococeneoumonamaca sah aepooacc 80-11 Incinerator: 2 hr. separation required :— [PeUblicrassembly.qunitSeie cut serun eects sa lars naan Poti ava oor 61-84 DRM CALTCS eee y tt ae «Sesto yar AR ee Ee eee 61-84 IMtspections wuTrees Certain CaSeSs meen ayers tale ie eerie ae erent - 43-35 Cabin caplantsHiCesi seuss tee a Nees es) Ae eG cnt ane a WA Wek a RA 43-35 IPIRAIIG .. 0, 0/3 Reto CPR ESKe DRIER ECE ne IIc Ine cine cick escrnateNaie hae A3-35 IMlaiuerralls gunGli@oinbeowngagoncscosecstoassodocbucsobensncsantoue 80-25 Occipancysprovisions Govern. «5. ans ee eiaeo a el eee an eee: 80-1 Oil Burners :— ANUIKOTAAHE Doyen oo uneels | Ono annesohaccotancasecnubanconcacce 80-22 BoLcompventilationsmegUinedl) 145-15 bene ee cicrenrereaisieeeae ee 80-23 ControlsssAutomatic shut-off required .y.-..se5- esto sae clon 80-22 Meanutalis ito fteneciuined saan A-ryaaeinncnet relies e meena 80-22 Defined as burner using :— 1eOsliwatheiash point 100 monmmores asec cle casa cee 80-20 Prabankaov.eral Olcallons capaciiymmmnnrertaetnt ie cise oie aici 80-20 Piping as required for Fammable Liquids; See Chap. 51, Index Summary Storage tanks, as required for Flammable Liquids See Chapter 51 Index Summary Plans: Heating plants to be marked on................ 43-14 80-1 MS PEGE OMELCES Mee artes sieves suc ghncereteee ea AON ay ye Sha aoe othe ese eo 43-35 Bsa oninonss Sia Gh Sle s oS anbasanosasnoeeonnanbeseousnAondc - 43-35 7, ahoprimoenerae |VIGHINGS, G6 Go cocoecnoaanonaocoubeeeuonduendanens 43-35 Refuse burners: 2 hr. separation required :— [eau licrassemblyaunits se ceri cei ean kare Gals os chor ses aes acciers eine 61-84 B., "TAGE THES, cot tts HORT Ree OES ic ood A Oe RO OS eT Sr RR 61-84 Gl 42 Heating Plants-Home GENERAL INDEX Heating Plants:—(Cont.) Smoke Pipes, Breechings, Flues, and Vents:— Air to circulate. freely around. «2. 2 ..0..e: chine ca acide ops eee 80-10d Dampers to obstruct not over 80%. .:5... cess dene ce ne ses oer 80-10d Exceptions not requiring flues... o.022 fen oe scien so 2 ele eee 80-10 General requirements. se... sa cos ancsrsie nica © nao eee eee 80-10 Lining: 2 in. thick, temperature over 800° F.........0.)......05e0e 80-13 Pass through only 1 non-combustible floor......................... 80-10d Pass through only 1 non-combustible roof........................- 80-10d Pass through partitions prohibited.......................0...02... 80-10d Except: From domestic stove or range. .................0020005- 80-10d Thimbles permitted domestic stoves, etc. only..................... 80-10d Temperatures to. be maintained... Js. 6: cso. e208 a2 58 noone cane ooo 80-3 MEDEA tLES Sete ieee tees creases esere reer eee rotten a eer 53-34 Thimbles permitted, domestic stove, etc............. 00000. c eee eee 80-10d Ventilation system.requirements:. 4. 22. 0.25.02. em ees sero 81-13 Vents, gas appliances, to have draft hoods.....................2..45. 80-12 Heavy Timber Construction Requirements :— AreaulimitatiGns: oe.c0 «Stace os at ae Orie ce oe Ue ee ee ee 62-7 Combustible materials allowed, certain uses.....................---- 67-48 Exterior inclosing walls, 4 hr. construction.......................0-.- 67-43 Facing materials of masonry 3{ in. min. :— Effective only for> of fireproofing 35.02.22 sus. dnt eee oes cae er 68-31 BIGEMLESUS «2 cocacr Ses ceric cits es okeio niece See Ska Oe eee ee 68-37 Bloor COMStrucCtion 8 5 s.62c05 5s ve Sees cee oe ee ee eee ee ee 67-41 PUTIN Pe soca enofokeG wieaesct, cee Ss oe rons oie oe 67-47 67-19 Grounds os ee face ot oid oie eoscsseieic SS eae ee oe 67-47 67-19 Lintels, unprotected, support 1 floor only...............0.....025005- 67—40b PATON Foci kiss cna ee hones hace AES ee 61-69 67-46 See also Partitions, General Index Protective coverings, metal members: (Same as in F.P. Const.)........ 68-32 MR OOhrs, che suerat ditus a des tuatieve GAS rae outlote ah oem eee ee ee ee 67-42 S Hructural fram esc 0% oe os ae ca asataes see eee eee eee eee 67-39 Height of Buildings :— Allowances above:limits: .22. sacs cr ee ee 61-20 Cast iron compression member limits. 2.,2...42..000. 05. 24.4 ene eetaenee 75-6 Cast steel compression member limits..................0 000000220055 75-6 Cupolas allowed above height limits.................... 00. e eee eues 61-20 Defined: Grade to highest ceiling line................... 0.00000 .0 0s 61-19 Domes allowed above height limits..............0: 0.0... 00.0 cece ceees 61-20 First story defined: 1 ft. or less below grade 40-1 52-1 61-17 (GATae O54 iis see areca eS oeesiine Seem en Noe Ree oor 52-1 52-7 Hollow unit walls: 50 ft. max. above foundation...................--. 73-29 Hollow walls: 50 ft. max., above foundations....................005. 73-29 Limitations: Buildings with height over twice width:— Cast ironprobibited si... 14.1n..on:Centers's < 29s: c.ctenc ac oiaie cases oe )er ene eee 64-78 Witla © VE 7 tithes ot ticx Paha ges wtedoneyn eens Sates ee ease eee ee ne 64-78 Landing; Floor space adjoining flights. ¢ «i ssic.... 4. o20s5 0% see eur oie 64-25 Lath and Plaster required :— Ordinary construction................ 61-65 61-70 67-53 Wood frame construction.............. 61-65 61-70 67-53 Lavatory in plain sight, food establishments. ...................0-00-05- 82-125 Lecturé. Rooms: Definition | sc sence se 2 sore © = Seine eee eee ete eh een tea 55-2 Schools, capacity factor 10.2... ec)s.5 css - seco oie tees ore 62-3 Tegislative TVA sss, ct Mets cate ee ice Sete ores Soest SR aM ee eects oaae 55-2 Libraries: Capacity factor 15.25). 2 coc eis, cscs wee «= 6s ane site pte 2 at eesti 62-3 Definitions. : <2 citen it tans sae saeantae oe ere ee 59=2 es) License: Capacity certified for amusements. ............2.0002cseee cece 44-3 Power to revokes 2.6 oP pediacie oa 0 © ava a era ere eee ey ese 39-5 Lighting, exit :— Existing buildings to comply by July 13; 1939... 2.022... cone ye ceeee 66-1 Normal :— Buildings as follows:— Business mits’: 2::.7:. aus ree ener erasers echo ere 50-53 66-2 Gl GENERAL INDEX Lighting—Live Loads 45 Lighting, exit :—(Cont.) Normal :—(Cont.) Buildings as follows:—(Cont.) (CINWRCIES sc ohio See se RI aioe tee ioe Cee eee eae 56-33 Garagess Class 1:0) ft. candle at floor............ 52-44 Hazardous use Units. . 6.5....06- 51-131 51-132 Imstitutional buildings:/General..;..............-. 49-40 AVitiltaeuSegoUTlGingsSeyaseis. cs acini tts < ieee rors eek vorsactsieeesrs Opentaimassembly-unitss...02-0.-8 assesses sence 54-71 EiblicassemblyumitsS...c0....s0s4+0++++ sess ose 55-95 SCD OO SERB po icsareesraieie ciauexe bm nists euarevuereions saateuere 57-81 M@heatress.Special requirements... ...............- 53-179 Blevatonrsemer-tcandleatevery point. «22... ..0-6:aaseseese+ oes: (CeneraleeRequiredeimall buildings: 2.5. 3.20. «. s2ae+a- Geese see: OnshoorsjOlpt- candle atevery point... .........200.e-eeeeneee sa: Onustainsewattecandleratievery. point... 0.4... -cee.ncm es os oe ener Additional required: Normal plus 20%, in. :— BuUsinesspunitsoeStOnies OFMOLe. 44 a5 aso. 4 lo acta ae oe elas COnnaie 2 SUOMI SS ARE chi cy iy Hes ea nO es ERA rem rt ars, aR Me gt Churches with assembly rooms: Over 1,500 capacity................ Churches with assembly rooms: Over 1,800 capacity................ Controlled only from inside principal entrance..................... (Caracece Glassmesh ASEMENt gaya.) aia cers & ene rete ie inches nis crn eleve weno (Gaineicalll 5. 5 oda eRe eee EOI TREIS Ur ruCH erp Sete Cee Crean er eee Oxvcrplestonyainvheighte x. sonidos cacao usin oe cielo oe Sein ae eee Hazardous use units. . 51-131 51-132 50-54 Insitutionallbuildings:/Generall: . 5.03.52. -12-0 0. 36 pone secu se oe nor PIO ETRORSLOLICS EN ODA ie teers aa ania cennceaate acto terete SCE Pialnhic agseimlh; Wikia aoommocemanach aon ma tdews coe atoo amos ee Schools with assembly rooms: Over 1,500 capacity.................. Schools with assembly rooms: Over 1,800 capacity.................. WNneninese GemGialle clots oo ateois Hae Mame lenis Geroimecsd eeselecin ola. SPECIAIESINMA TIONS a2) odics wis coos ast ecg etoremels tae es oe sates a rere Signs :— Wirectionaleomtacandlesa-) sss. nee ee eee Seen 66-14 IBprateo 5 7Re.(Cenava lee a seca acest ne aaeP O PIEcoe e eeet we mae IF@ GORDO! Sites tee el (eee weer praca eae ease ears rec eicacn mre Oa arco or 66-17 loomindicatine-7ohita, candles sas sa-- 4- acaeemee cae se cee ne Lime :— Omelklimeito berslaked 48yhourse. oa... 44+ oe ae hase tice ee ees Limits, Height — (Garena 5 5 oe See eee APE IPED eA De Se RR, a POF 61-18 to NWedsunementwomileightaas seein roe omer ae vere eee IREMENOUSES SPIKES; COMES ieee). oy ss aes oo lee 61-53 See Height of Buildings Lintels:— IES CaGUTN SAMITTTU ASTD fea os gh.c ciense ig ce fan pagel Mea or ts eneveeT ae ovat kegons dake Seance Loose, unprotected: Openings, 33 ft. max. Fireproof construction....... Openings, 35 it. max. Semi-fireproof const... 7. ............+.64.s05 Supporting 1 story only in Heavy Timber const.................... Masonry arches: Wood allowed behind: 2.2.5.0. 6 ee ees eee a nee Metallintelssnmeimin bearing: 14 pieererinneiieicisis ietcicie cme eters aer: INOnecombuUstblesequirede prairie mene erste Telia eel kr keane: Except: Wood lintels behind arches allowed in Ordinary Const... .... Reinforced concrete lintels: 4 in. min. bearing........................ With unprotected shelf angles in. :— BITE ROOMCONSECUCTION ¢5.. & 4 \o MME ME RiES Soe omc iceiaeee nie alee SemienineproomCONSERU CLLON acer erie ii ele rite ee ieee eae GOMloaddyareas Solid: walls; no openings: .-2.0..+-----..2-+-++-nessess: Live Loads:— Mutorstoracespaces,o,000 Ib; on 4. it. X 4ft. area). on. mes wee eae Dilawéliaye (0) Bini ora eee ene ETE OT OAS ROL aa RRR ete Rioomplacards:, Pallilive load specified. oi. 0. sw a ce iene oye ale nvare.cpuctae Generals various occupancies, Pables or8 oi. ee ec o's 5 on oye tno lageper eh 66-3 53-180 66-8 66-8 66-8 66-18 73-16 73-20 73-16 61-20 61-19 61-20 ~“I~Is™ Siete PON OG Ww 67-7a 67-24a 70-20 70-4 61-31 70-7 70-1 Gl 46 Live Loads—Lumber GENERAL INDEX Live Loads:—(Cont.) Reduction: Beam, girders; and trusses. 52/5... 04.0004 ecee hae eee 70-8 Columns;andpiers. os 3516 o.oo ene eee 70-9 FoOundatlons<..<5- 2 Sadad te de tn fe is oe ce fe a eee 70-9 Slabs ANG, JOSE. ia 50's wis osenecd shoaits Se 6 Ba elo Oe aie aac ee 70-6 Walls ii ous. cccccia ictewe sk astotn ) sah ne eee tak en ee eee 70-9 See Table, Sec. 70-9 Roof loads: Combined with wind:— 25: IDs PCr SQ. Ebsiacs ake agrag iste tee wale Ad dG aden ae ae eee Cee 70-5 Normal to: surface seca 24 asics ois eve sy ties hoe a eee 70-5 Temporary, over sidewalks: 22: > we ts.acnans scone ds see eee 61-8 safes: 2000 Ib. on space’3 ft X38 Pts 5 224 coh ato ec cre Fetters ne 70-3 Smoke rooms? 75 1b; PEL SGa ite. sc-nsae Pow ed oul cee ora sue eene ee 51-48 Special loads for special iequipment......-.4.4.0043 2:08 00 be-e eee Oe 70-2 ‘Temporary roofs’ over sidewalks. <.. 364.03 si.0,. 2 so 5005 s00ee eee 61-8 Wind loads:— Beams\se@ Tables sc0.0 s.daacdisns od osiowotitieane lenere are Seen 70-13 Chim eySic, dschaed anc sesegiicae vis arc tos. dos aie cuisines ao ie ee ee ee 76-5 Columns, see Tables... 55060 0.-e00 cette nes de oe he oh eee 70-13 Combined live; dead> and wind loads... . .......00. 660 o: ce 5e ooe ee 70-19 ach: side of inclosing walls): .). 42 .0é« ..0 sts acs nar ele back ae nen eee 70-11 Flag poles: 14 Ib: per sq. ft. of flagvared..... .4...s000c5+seh ee ete 70-18 50 lb: per'sq. ft. of vertical projection ..5:.....4iuen vaca eouee te 70-18 General 2.25 tik oo idnieat cpa bey EAS Roe RE Ae oni ae ae ee 70-11 Horizontal wind pressure either side of wall...................-0--. 70-11 NOISES icaateee ayers ceo oi teci eee cckeee toveec ce lonac cca eee eS oy acter ate eee 70-12 Overturning Moments sie ses arsers a scrse os hess Aaa enn emer eee 70-16 Panels, skeleton construction... ..< o.2 un avcnk oo sraeee oon notre 70-12 Partitions as tesisting members. <2 << 2 .3.<40-eeeecceets esses sees 70-14 signs: 25\lb. per sq. ft. vertical projection: .. fiae.d0sns00005a “cece 58-67 30 Ib. persq. it. vertical projection .315fse0¢+ os2020 ohne eanceee 70-17 Sloping TOOiS ase shee eee cies tree eee: 70-11 70-5 Opeeial SETUCEUTES 5% c.0.26.5/0% sais ni eth ew aceondiets «5 seseeee eee 70-17 SLE Ge R IO TO eae EEE Er IR ee eae daira: 76-5 PUGS Sree. 2 eas we Pens ciiat tian au aera eeeny a cine Main cere eens 70-12 Table'ot windiloads ayy 627. fcc ae sorte witout oasnssne eases oS er ry err cae eee ae GEDA. o 2 o..06'e Sarg OAD Oe ROI eS a ee ea en eee Sees (sD EEUADISES 5 yo bh a Ca ane Ce ee» aa a ae Re hs PP ay oo ee Sayeaal d/h aie 4. 844) shad Siouw wl So IO RIS ee Gere PRIMETIME Oe tts So nee IE 5h ois ts, aN spe dtravacel an Sled eStats Stecmoni dings ssAllimetall walls. cs... s .scee ec oes e ees eee ne here Oe Cement plasters gaccecuemontocapaononoas see beans one sen dc BEE Te OH OTERE MAND ES eye fete he 2 ye ones Sk nb) ats ous ph paoien au wie pO RS See Chapter 50, Index Summary LTRS SE BTN ES 5 CSR nen RE: ao eo Pe Masonry, General: See Chap. 73 See also individual items in General Index, such as:— Anchors, masonry Chases Walls, etc. Bond Parapet walls Materials :— Commissioners power tomake-rules: . os... cs ees ne oe cone ae nene Gormmniitteeronestandards sj. vere cscs cls vor i ec hea, ee explosionshazard, Committee onistandards.................2eer..i..4- LOTR (HOSES, JAA ISAT INT OFS ROS eee ie ere en rele ice nl eee ae Hum eshazards|Committecionistandards: . 2.24.5 0.. 0... :s80s000 0.000 lnliglalhy IMVAnGlOWS..% aodpeo bs SHS 08 CLO O COE Oblate o DRO ne aon ona ce nr NIECE Tintern CHOC ENCES Gee ABoM oa bona ae on ea onon nie sete caren s aan Except: Ordinance specifications govern...........-2:.+e.se+s2-0-- INontordinanceymatenials: a0: .56.0esscsss+ cee ss eens 41-2 Oxcinancerspecilica tions ZOVerMe +s). res aie le Se acces ie sllene oa oe Ouality-iCommissioners power to make rules.............--..s:++++: IGE? SANG ATCO ORGS LIN Go ooo anonenoocuds uate jo oted cin odes ote Ordinanceispecifications:fOVern). --- 0-2-2. osee scores mee cece Riless@ommissioners power tommake.. 0.0 .0....0.0ee esses eee es praudardsioimaterials: Quality... cjcce os cas scene bbsaeecares cece MESIsr ee APP UCAUIOM- LOL. Ai’ s een ee. veer csie © reer e es ok aie. Mee ee oe IMG Serpe ee ye rer eee oe ear A ek ee a eee Soll tests, WO AAR AES ISU Noe cea .5 ip oe Givi od ion Cain dale acolo o dob -c Warpins noun @abbenNGsIy ooapooeooobnodee opoouocn decode sondooce See also Am. Soc. for Test Materials, General Index See also individual items, General Index Means of Exit, defined: Means of travel to egress..................-005- Mechanical amusement devices, See Chapter 54 and 79 Index Summary Medical School :— Woorsiconnecting«with institution... a2cssseeesse soe es oo ene ee eee ltacieneirenerarn)| sunietinyen, Gopaeeconoe cece so pve non eaosbbocaacosacesuane IMIG =(GO-TOLUINNG I Gis aisha ct AE Ca ERMOR Cle Bice cl sticu-r eer OPN Aan ani Oe cap cectic See also Chapter 79, Index Summary Metal Chimneys: See Chimneys Metal Frames:— See Doors, 45 min., Metal and Metal Frames See Windows, Type A, Metal and Metal Frames Metal Structures: See Exposed Metal Structures, Chapter 58, Index Summary Mezzanine :— GRC RPE Meh ale acta. c 552s he oe natres ie bya h hee an ores cdictc eta terige GCA CEC PER RES cit one ANAM haa es od 2g Salk amend Sat 48 Monastery—Multiple GENERAL INDEX Monastery :— Dene ds.: ach owe, oe ered 2s eles ove SS eee eee 40-1 Multiple dwelling? o <0... ane oa ceneciare o - tape nee er eee ee nee 40-4 Monitors:— AS fire: TeSiStive aS TOOL. 420s sc. a so sett o fe so 2a oe . enteaeee ae canta e 61-63 2 4t., over. 3 tt..fromilot lines... .¢. ceo. cc. ae arene ee ere eae 61-63 1 ft..at:cableend of pitched rool.2 5... 3. oe eee eee ee eee 61-63 A ft.On, TOOL Garages >, «clos scnsiore gla eeuee cae eR ee te otek 52-15c Mortar: No. 1 only to be used........-.........0.25: 73-34 73-20 Required on Non-fireproof buildings :— Qn walls: Fire divisionvwalls.....c.0:.2,.:2. 0000.80 dotnet see eerie 61-62c Within 15 ift.of lot line.) tec iy. basen oon oe eee ere: 61-63 Within 24 ft. of opposite sideof alley... -... (Sasa arerns eee oe 61-63 Exceptions: Roofs with 15 ft. of 2 in. tile covering.................. 61-63 Street front walls. 23... 5 saissk ss hasnt cee Oe POE eee 61-63 Gl GENERAL INDEX Parapet—Penthouse Parapet Walls:—(Cont.) Sonal wwenllll Reve(uiinetaly, Sa cacra crn eee, Ge Eee OO re ER an oe cen Mhearrespwithimo superstructure Over stage. ...........-..5.6sss00006 dibickness;sametas wallibelow.....4..---+-.-s+«+or5-- 61-63 Partitions :— Fireproof buildings: Non-combustible partitions required.............. Except: 600 sq. ft. area, sub-dividing partitions.................... Semi-fireproof buildings. Same as Fireproof buildings................. Heavy Timber buildings: Non-combustible partitions required......... Except: 400 sq. ft. area, sub-dividing partitions.................... Ordinary constructed buildings: Dwelling parts only :— WieodBlathvandimlaster (Ors. ia6.260.< ase 6 sa ae cen ca emmcimdon s+ oevene Metalslathnyandes ins plasters O©s .,. 210s cece 50.5 eos ececias cree elves Crhemsunslatheplust> in. plaster, OF. 210... «aes cas acs ose e- Others hr rating, material, sanitary surface..............-.:+-.-.- Ordinary constructed buildings over 2 stories high:— ibasementicetlings: to be metal lath and plaster...................- Wood frame buildings, same as Ordinary Construction................ iBuekirames. wood studs used-between. ...2..0..+s+esseesecwsesecers Business units:— BaseMmentpartiuons: 1 hr constructioni..........4-.++++o.-+>+ss+05- Over 2 stories high, metal lath, plaster throughout................. Chimneys through partitions, 6 in. max.,.............. 61-91 Fire resistive construction, hour rating: See Chap. 68 and Table p. 236 Fire separations: Resistive construction required.......... mien ene eee eds Fire stops: Maintained through hollow spaces..............---+-+---- Raligstony@ueinhtapantitilonSs. 26.6 eicm..2 0c 2 5 eee oe eens SeGhe ciieieseuete der: Schools: 7 ft. 6 in. office type partitions:— Clazedbiromes: ttston/ tty OMe Mele htSe Construction :— ATeancombineds Not OVel 25/9) Ol LOOM Alean see mies elsleie-f--)s eke = ia nnn I aD Se Saas ile WWD &% W 46-29 61-53 61-53 61-53 61-53 Gl Sy Penthouse—Permits GENERAL INDEX Penthouse :—(Cont.) Construction :—(Cont.) General: Non-combustible maternal for... ee ee eetiae eee 61-54 Except: Rootto beysametassmain roohec. «40.70 see eee ee 61-54 Located on roof under 50 ft. above grade:— Walls within 3 ft. of lot line to be same as in story underneath..... 61-54 With roofsame/asimain' root. Secce coma Seer eee eee eee 61-54 Door ikrequiredito;maincrool, At iataso 44s ee ee een eee 64-10 Flat-roofed: Requires 1-24 im..stair to. its rool... ..4.- vaase0 oon 64-11 Ort lel4imr, Jad dery.c/s.263 ae asa: sateen nk ee Eee 64-11 Stairs:1=240in. accessistair required. cqornw 5.2+. 2 oer ee 43-27 60icents per. 1000:-Over 200,000) cubic ft... 7 ee aa ee eee 43-27 Canopy; PlOUO i n8 8 seins Sarco be oon se ae 2 eee 43-30 Chimneys :— Tsolated 2$1.0.00% sey, S ob\enh ch eee ae ae LEO ne 43-30 Over SO0ifthigh! $1000) aa. 4.5 8. aac ae ae eee eee 43-30 Blevators,: 500). hata sac deters: «cos aves cierto eo 43-30 Fencesiover 5 ft.high: First 100ft.,. $2100. 7. a. on eae eae eee 43-30 Hach additional 100ft. $100" 2. 3 ).vckste see telon oe eee e 43-30 Firevescapes;, po/O0wirst,4 Stores.a 5, 2 Sc x02, voc cee cide pete etn ee ee 43-30 Bach extra story $O7Os 6 2.65.0 5.cad Ge ee ee eee ee 43-30 Hloorload: placards) siete setae se ov sects tiete oe ee a ee 43-33 MUGNACEMNSPECHOMs wx. deat oten a sets caso eeetetient eo Oey tenet eee 43-35 Hurnaces: warm ain. .b5:O0Oies. 2 sccm ceetcicaroe Sess Sak A oe ee 43-35 Marquee; STOO! nid toi cncts et rnmcsnbis Pct tae adptie a costes en eee 43-30 AVERT TERA UTA’ 522 ODN al Pees oh latch cee Na oe ON ech Co oe ee 43-27 Moving frame buildings, ten cents per 1,000 cubic ft.................. 43-17 lel |b hao! oh) nae ARE Aan CON ne Vik Me UMN MCC, BN eRe MAL Fae cd Gun oc 43-34 Raise building other than frame building :— 20 cents: per, 1, 000\cubic ft3 32.234 262 <4 <5 atest cies cee eee ete 43-28 S500) saat, cdo hatte sae oie elead coe svn sabe ees idee 43-28 Roof signs, illuminated :— 1st. 500 'squit. $5000. 24 eins oe ook ack ede ee ohn oe ee EEE 43-32 Hachsextra.sq? ft. five Cents ccce esenwes sacs o<. 4 oe Ga eae ose 43-32 Roofs; TE-COVELING 5, 50..0,5.,0) Bids s LS Sts tay te eve Rudd Si eee 43-30 Sheds:upito. 300 sq: ft., S300; oi... sist arn ical « aune ee eee eee 43-26 Sheds; shelter $2.00) per 1/000scubiciit..- «2.450%. vce ous 43-26 SIPMDOSEGS Prgacns keene eNs, oye eee ions oO Ort seo Cae eee 43-31 SIGTIS jects ens oy RIS aed Peco alae a at pea evan et nase ee ee eee 43-31 SprinklerssystemsS2.... 927. iy.GG.cel- kins © otant sa nee Oe eee eee 43-30 Street-obstructions: Se Sen.s ca ak lc ane neo Gh eee eee 43-12 Tanks: fammableliquids:.. 2.208 ates iri ae eee eee 43-30 Tanks, roof:— Over400igallonscapacity> 10:00 tn aac ce oe Oe eee 43-30 A00scallonsyoriless- Si00 ease An ees Saeco Oe eer ern 43-30 Over 250 gallons, structural supports, $10.00.................:.... 43-30 Ventilatine: systems «cw Rescate ee ctnotl ores bara eR ee eI ee 43-30 Water used in building work :— 405; per lO0OsbriGks: aeeuints 3s eo nea eee ere 43-6 06;perl00icubictt-mubblesstone® . 25 = a5. cm ono ener eee ac 43-6 108 perlOO\cubiciit concrete: .1 224d). to eee eee ces 43-6 HlouperLOOtvardsplastebar -t: me ate ccs oe eer eee ae 43-6 LOSiperlO0vcubictthollowstile: ee cor io epee eee eer 43-6 05:per 100 cubic ft. hreprooficovering 55-4. eee eee 43-6 Wreck buildings over 1 story high:— 5 HOO ofc ah en eo EO ERE Ls adiuadadcdeb cake 6 O00 43-29 Permits :— Abandoned construction for 12 month period... .......22....-------= 43-9 Gl GENERAL INDEX Permits:—(Cont.) ANBYDINGA ENON, TOG UU LAVSINES, Gh c Bete asec sle Eee Ce OE es ee ALLE OMAIL GUND eq od Ula oo oder oe oie ene es ane inoilewapprovallrequiredifirst. =. ...2....0-.5. 50.0255. 43-14 Bonds wacemnity Dept..of Public Works. 3.0.05... ......000..00-005 IDTENRMAYTS ACUTE 10 cecteintchonck A OMA OT SEREE la oe OE eee Ne eee! DWrivewayapermit required first.......05....5..4...5-- 43-8 Fees, see Permit Fees ERMMACE FADD GAblOUSHe-a meetin, Sroiorva. te a eines ised wae sen ees General: See Chap. 43 Not required for fence under 5 ft. high................ 43-16 Notnequireditorminorrepaits. ...............2.02.:. 43-2 lantapprovalyother departments. .........0.0c.s sees ce nee se eens TPIS TREGIEUIRDG ,. 9-66 tale kee eeme RUMEN RRA aT ate et eae. rear ae eee 8 FA REEL, OH HESS... ovo Gs ope EOC Re eee eer ee ee Pe a ee ee ae efusalltoussueypermit, atter violations. ..........+...5....++..s20-: IRGRISLELCCECOMELACLOLS ONY pr i. ayy een s es ee ee oe ee eee Reinstatementaatter viOlatlolia.. sc-.42--144s250. ust seek eee se ee asee « IRCESTHS QIU MICIAWOM. odin. nis Satan Aaa neni a Beene eh near: IRemeWwalss Extiemaiiomne 7 oulhi7, 5 oonin ane eee besos sonsbenbencasesdac Beem womorigimal COSts..2 fs. os maven sends goes see ecemeeecs ERIMLGECC MERE oe Gr eee ys srw Reena Ny aes foe oe IRNCDOLIS MCA mene Carne hrc ar ltrs a osu ee an o noe tech cece ae Required :— lEWOLKsexcepe MINOr repairs..:.:.s..+--5.05s4- nee 4 IBekoregwotkastantSmrscrs seit ysis e as cm sven slats 43-1 CCATIOMICS MPR I eee IN Coie casi Savard a ecko. wah ee Le eae IBLE PRUOHS » x 3 66% tee Sie Dae Ete UCR REN eee ne PE oe Bxemp HONS wmMINOTMrepairs......0..6.2.52012s.e0255- 43-2 Mechanicallamusement Gevices.............: se. c- sence well a: Winlawiulktomproceedvatterrevoke........5. 26. oc ese see eee. Workicontrany;to permits unlawiul... 2... 5.6 cece ee eee eee ue Workenotaitectine ordimances............+..-.+.5:-: 43-2 Piers Isolated :— Bondedtevenvealtermate COULSe ns acres rns enemies Bondedrareayneed notiexceedy20 9 of face. 4.2.52. ..5-5-+2+ ccs TRISTAN (ETN APF Ce RR er dete cs peer ege eA eee ee eR Rope Rae en Rn oe Soli@imasonnygrequinedia nares reer oe ieee ie oie ne Wrallipiers) 241m. /or less, defined as isolated. ...........-...-«.+-++5- Piles, see Foundations Pipe, Smoke: see Smoke Pipes, and also Heating Plant iacands-s Dangerous pulldingyn. saeco ss oo tees nec ee on nee nea: IMkoGar NORMGLS ccc ue acento cpio cam cra or Nace 13-8 61-1 PI VOVE RENTON, Guha 5 Shoeaae Nerney ait octets 55-2 Plans :— PNITErALONS iby Me waplansiOnliy;ves erect cairo ciao eet Alterations by new plans only for fire escapes.../.............-..-.--- Alterations to stamped) plans prohibitediy.8.) 4.4.2 45-. 506 2 aoe e ae ADMUSSMEME COWES od bonasdscvodcuobun sues bacmoboe 13-7 INDpLoOVvalsperore Permit. :5.....5..-5.- 13-20 13 Approval by other Departments :— Boandgoterlealithys <. ak hte alpen aetna etre accent ne east ehe ome See Fire Prevention Department, General Index Chilis [BiIVEANTYES 2. col Rea EERO SL Ar ee ene A ce BI TEP IAS CE: DepartmentoteBolerInspectiontme......404. 6 eee 43-4 Department of Public Works:— Dah CENTERS SS sons Riders MAG eRRnOle Sp olnels sendin oioteeoete 43-8 Cane cosagaedoe 43-4 45-6 45-8 WepartimentomsmokenSpectionman wee er eis cierto aie cere acne ISSA OLS Sravalls Chills, hc ono cdogedomacno06 SoqocosopOmOUsHagds Reespremittedemmpes mere ere rie ie rere icine Sera steerer ic te 54 Plans—Pool GENERAL INDEX Plans :—(Cont.) Approvalistamp required)... c.)02 os cose 0.0 cote ei esis oe eee eee Architects certificates: See under Achitect Architect:or engineer to’sign and:séal ©... ; 5 ...22 Oy Registration of Contractors See also Contractors, Registration Reinforced Concrete:— Aggregate :— (Ciicayycl PPC srr es Chee Ss sya eee on Oategm atlas Re aaa Bees American Concrete Institute: See Design Anchorage EATS HE COMM OSICe Mery pals Neos craic suas i, Nave a lehiecas epoca Meet Dee 74-10 to WEE. » 9 0 6 6.6.0.8: d Hat Re OER RE ao ee eee ee en Chimneys :— AS HiMaiMenWANGtMIGKNESSs Qo eiec ca cnehscceav ewe dirs sv eeeenaaae ILATNOG, 5 so pod docce COOOES One ere 76-27 Colle! wienlilngr negminementts, jobepeocoepeoeebpuonuboodbosuueosccodes Columns :— (Continin acl OM meer sn yee ysis Ger ee 65-29 Non-combustible throughout... ........... 0.0 cece ce ee cence 65-25 Painting required ..<. 0 sds ccice iscsi ene ka vie oe ee 65-28 oneet metal construction details: 24... sseac sen. »¢ ale Mone ooh een 65-26 sold rolled steel construction. details... , ..4.. ci sides suns noose 65-27 Corrosion fumes present: Wood members allowed..................... 65-22 Curb, same construction as roof of building........................4- 65-22 Except: Wood to be metal covered.............. 00. cece eee eee ees 65-22 Frames: Non-combustible if over 50 ft. above grade.................. 65-22 Non-combustible or metal covered, if:— Over 1 story above grade, 50 ft. or less above grade.............-.- 65-22 Except: Wood allowed in corrosion fumes................02-00005: 65-22 Garage, Class I, Type A skylight required:— Within 16 ft: of dividing lot line. 6 cn c0 s $< 208%... Ce Oe = sae ee 52-35 Within 16 ft. of opposite side of open space................00000005 52-35 Glass, prism, 16 sq. in., $ in. thick:— Allowed in Pavement type skylights... 4.24 $i0.0es¢ 0s as4 oe Seem 65-23 Allowed in Sidewalk typeskylights....5.4.. .<5+ sc0400s 00s 00 eeyeeeioe 65-23 Non-combustible structural members required. .................--- 65-23 Glass required, Type A skylights:— S + in. thick, with # in: mim, mesh. 3...4..< 296 (..0 = 1m ee hire 2ineand 4:in. construction required. .4.-..:..5.-.....-..-= Binershieldsstainsamasonny, mequireds- 0... .e-e 12 se = tae Doorss45imine ype required. 22.22... ..)-..-%22-02- 61-24 Except: 2} in. wood doors in dwellings 4 stories or less........... inershieldistaim smasonny, required. (2.52.2... .25.02 0029-50 oes Inclosunemequired. except imilstistory. ..--.0.-.05.2+4--se0- 5-90 Time) ORO, TRG HUET ee gs Oe ee ae ae cee icity Mavyaberopenian 1st story, combined stairs.: .. 3. .0 0. ae eee Stairs inclosed in 1st story: Access to basement prohibited........... Wemticalll Sitentisi, SeGieat ae mion cine adie aceon Oh. ee noftotoisa toma alnt : Wellirolemm Closures )4).s.ths a anere sien aoe 2 oe pues pumncen ans stats hsttenrac \Whirnclonrs, Atos Avieeeibbigetl oc oianana cond bocneocooagoucdoagcmogac Landings :— Mevelblandimeanequine dieser araverils rat tetera hte aed tee one ire Level landing 4 ft. long, between ramp and stair................... Anitelonees Direction Change OOmOrilessma saa ie ee ee Wideas stair: Direction change over 60°. .........A4.0--1-+.----->- Location, 100 ft. max. distance :— AuvapompEon habitable floor to stam... 20 ¢sees anon eee ree: IMiGagiemmec) Gia Ihhvs Cr toes ano Ao nane Bows otov mobos seg onenomae See Occupancy Chapters 47-58 Multiple occupancy communications only on main exit level in:— (@iCheSieer ery a cs crova eens ccs crane OO AGN Oe eee choke econ ee terete (GORE. fe ae PRR 8 APN Caras Reena fe ade IRlArANRC OWE TAS Whats p onerace od eb acc cue tooled oc ompomced pmo Go aac TRUCSTONI HEIL oo) A ee RAI Pos NOR OCS he oe oan NS SCHOGIS Mee Marne as on 35.5 Ua tnd RIED wicul& chacintatdolne watts pees MINE ALERE Sirk Sets os sles Ms duswsln, 2,00 MMP ae ee nd cl eens eel oe aot Me as INon=requined= Samerasifor required Staats...» teil eter Except boca tole pers. oven Accs “aera soe ke Sete eraioe ie ee ae Prohibitedinisame shart withvelevatote ances. ote cae de oe tel Required: At least 2 in building with Fire Shield stair................ Except: Buildings: 3,000) sqi-fts orless. sr .2 Be et a ae aliens 64-28a 61-21 64-28a 61-21 64—28b 61-21 64-28b 61-21 04-44 64-28 64-28 64-44 64-28 61-21 64-37 64-38 61-21 61-21 61-24 64-32 64-32 64-32 64-32 64-29 64-29 64-7 64-7 64-7 64-7 64-7 64-7 64-30 64-30 61-21 64-51 64-51 Gl 66 Stairs GENERAL INDEX Stairs :—(Cont.) Rise and Cut:— Business units: Risé, 8.in.,.max. (Cut, Sim. mini. seeee 64-31 Churches, aisles: Rise,'8 in. max. Cut, 10 in. min........ 56-24 Churches, general: Rise, 74 in., max. Cut, 10 in. min........ 64-31 Fire escapes: Rise, 8 in., max. Tread, 10 in. min...... 64-65 Fire shield stair: Rise; Siin., max. Cut, 9:in, min: 7. seer 64-31 Garage: Rise, $.in., max. Cut, 9 in. min..4..¢e- 64-31 Institutional Bldg.: Rise, 73 in., max. Tread, 10 in. min...... 49-22 Except Hospitals: Rise, 74 in., max: Cut, 10insmini nce 64-31 Except: Teaching amphitheatres not in hospitals or schools Rise; $in...max: Cut,/9 ins mine oe occ se os ase 49-22 64-31 Multiple dwellings: Rise, 8 in., max. Cut, 9 mmine. Anne: 64-31 Non-required stairs: Risé,. 83 in., max. Cut, 9.in: min +. Saar. 64-31 Open air assembly unit: Rise, 8 in., max. Cut, 10} in. min....... 54-50 Public assembly unit :— Emergency exit: Rise, 74 in., max. Cut, 10 in. min........ 55-69 General: Rise, 7} in., max. Cut, 10 in. min.......- 64-31 Normal exit: Rise, 74 in., max. Cut, 10 in. min........ 55-50 Schools: Basements: Rise, 8 in. max. Cut, 9 in. min......... 57-49 Teaching amphitheatres: Rise, 9 in. max. Cut, 9 in. min......... 57-42 Others: Rise, 73 in. max. Cut, 10 in. min........ 64-31 Single dwellings: Rise, 8 in. max: ‘Cut, 9 in. mine.ceas.e 64-31 Rise times cuts 700075. cava ace ces fais 2 oaen ose a nee 64-31 Sharp internal wall angles eliminated in:— : CHULCHES f incleg esc. o2GOe be coat ecoue Sameera eee cteue ee eae 64-39 Open‘air assembly-umits! 55. 2ate.gn i ee eee oe eee oe 64-39 Publicassembly UnitS', 3.5 cc, .c:cntadehe sag are oes ae se eee 64-39 SCHOO! bis cts 5.0 Saas deer sess), BORAT etd 0 oS ree en noe 64-39 WEDGACIES:: oo. 3 GES S eeertea at AS LAER oe a Choe eee eee ote aes 64-39 slope over 45°: Defined as ladders)... : e.Geeieeiateee wens eae 64-77 Space under bottom flight, non-fireproof buildings:— Must be completely closed, no access; OF 3. fo. icanacures nye Heanor 64-35 Must becompletely opem® «= ctaectse cece ee es cree one eee 64-35 mteps: At least'S required In interior stalts.. <0... <¢s.s20s oes 64-33 Substitutes for stairs:— Bridges :-— Connection over open space over main exit level................. 64-15b Construction to be non-combustible. .................00 2.00200 64-15b Department stores: 40'ft, max. length... 200.2. oes wee ons ee 64-15b Sprinklers required <2 erecwsee-eysiscis oe ssscieeate ele snes one ees 64-15b Doors: Seli-closing réquired 3.2.27. See o,f oe « grec eee 64-15b 45 min. required in Fireproof construction..................--- 64-15b 45 min. required in Semi-fireproof construction................- 64-15b 60 min. required in non-fireproof construction...............--. 64-15b Exceptions: Not permitted in garages, hazardous use units, schools, or CHEAETES. cies ners varsieccietge a eke «5 /tsayedeln, cleus + tye clo Soon rocmee 64-15 Ends: 2 hr. construction required in fireproof buildings............. 64-15b 2 hr. construction required in Semi-fireproof bldgs................ 64-15b 4 hr. construction required in non-fireproof bldgs.............---. 64-15b Floors, may be ramped: Slope not over 1in6...........2..+e000005 64-15d Location, same as for stairs...............00e0000% 64-15e 64-29 Windows, TypeA, required’): J opi ..cs i. ¢s oa)0s ois os oe Syoeitersie rier lane 64-15b Doors in dividing walls, except main exit floor:— Department stores: 5.it; min.iwidth. «<<. o0,..ccuseamronets seuacels o = 64-15a 90%) of main exit aisle Width... f..c4 ose few bee aune ee arcs 3 64-15a Eachside. to bein exit line of travel)... 6.2 essuenitieegr eg eye reinee= 64-15a In‘liew of tof? required'exits; 5.45 fc scetic e eex eae 64-15a Exceptions: Garages, hazardous use units. .............--eeeeeee- 64-15 schoolsiand ‘Cheatrese 9 = spcjene's creeie ci ete cceiniere ae pe eer egekens oie vener 64-15 Escalators: May replace 1 out of 4 stairs... . 2.2.22. .s02cee eee nee eee 64-58 See Escalators, General Index Fire escapechutes:'Generall <... ..<:c tea. ae 2 =.cenetaeae racer oie enn estee ere 64-71 Fire escapes in business nits';...5 5s <<<2s\-e «pagan eee nero scien Crier y- 50-37 Fire escapes may replace 1 outiof 3istairsiv. « o.gneeeeero asi askaee ctor = 64-61 Except: Buildings over 6 stories high. 22% ..0. Use formula, AOo >. 2 Seen aoe dike od te ete eee 75-9 Materials: See Am. Soc. of Test. Mat., General Index Mortar covering: 4 in., incased steel (not concreted)...............-.. 61-101 Non-continuous:. beams: 705. Stic ncn. oe oes emetom Pee es 75-12 Paintin osteelgy ore iadac,) tee anes ae ea oe eee 61-102 Steel in concrete, same as in Reinforced Concrete................++-5: 75-18 Steel shell buildings allowed :— 50 ft. from any street, alley, or lot line for Manufacturing and Storage UUMIES sss oY aes ho Bh orale. ot neg sistemas Gite areas Oe ere ener 50-9 Stresses :— Bending... tiie fs cine de vat eee ee sen ee re ate 75-7 Compression :— Column ‘formulas: (Géeneral.. 2... 520. So. oe ee a Pie 75-6 Formulas: Long members... 2) 440c25 0. ¢ epee eee ee ee 75-6 Long members’... ..:: «sc adie ates dae oie coe Aun eee Noel Reese eee 75-6 Short:-membeérs®: ¢ o..... esx dee ose cae nee es be ee ee 75-5 = TALIOSs sidis.nt Shhh See tee ee ee eee 75-5 75-6 Gl GENERAL INDEX Steel Construction—Stores 69 Steel Construction :—(Cont.) Stresses :—(Cont.) Compression :—(Cont.) > over i1Se WS lignan bye 0a a piace tichcte Brg 5 ne eRerSe ee eee Ree 75-9 Shears General, . aig dca outa certian a Mere cae GRRL te nic oe 75-10 (GitnGleie GHGs 5,6 Ge Eales ROOM One ene Cec Se 75-10 ‘Wemeroins Greiner le ta: -ce 8 cho ae Cle ei ne ea eee ee 75-4 Stress: Reversal requires; rivets, welds, turned bolts.................. 75-15 Thickness of metal: Exterior construction :— 5/116 in. thick, when carrying over 100 sq. ft. area.................. 75-11 Thickness of metal: Interior construction :— WATMathick when Garrying over 100\sq. ft. area...............-.:- 75-11 Pxcep ew anllersramGsnmMIN PSs. a2. cr aes Science oe feces secre cae eee 75-11 Webs of rolled shapes, interior construction...................... (Saul SINRUGSECESTCCIM OISUSPEM ete rts arts: Oasis Smosh deiy Aaa eid ake ene 78-1 Welding :-— To be in accordance with ‘‘Code 1, Part A, Code for Fusion Welding and Gas Cutting in Building Construction,” of the American Welding Society, Edition of 1934, including Appendices I, II, III, IV. Mee RIG SMSCAM GATCS rare tere ah cits sacks ae eideye sucsetentrers ue icrne ea otra 15-3 * (PASTTEANTE@G «6 0. o:bid-c Bee ENERO cle NE ec Renee cM ee ee reer I9=2 Strengtnon Wjointas that of welded jomts........:......-.:.++-25: (-? Ormequalsistrenethvofiboltsiiy ae nec oe em- cece es aries ee oheecie 75-2 Ormequalststnenothboforivetss «ce a. amigos clas soso oe eee 15-2 SURCSSCS MEI esis fs heag se yeve cremains oeiow «aaa oi 75-4 75-5 Supenvisronyotlesting (aboratory........-.2 ne eeueneeters 75-2 Mesto Centiticateorarchitect ......:.2..se+ssseeescss nes 75-19 Certincatelotencineer, 5.4.22 eee ge eee see eee pre erie 75-19 IRECUMGEMNeTIUS ERR E es anyon cs a drs, ce canta naan Salter Cee 75-19 Welding in rain or strong wind prohibited.................0...... 75-19 TE Saeaye TES LIT TORMO MWS. ero UN ae 75-19 LG DEP ARETE ACM WALHBIESSTISC acts auays,. oa ciz.os.ee oe moe reverie aes Seishaies aleve sveheustelaiens 64-25 Stock Exchange :-— Capacitvgiactomisiotrading rooms. .-..s.-- 24.4.2. 85as sesso 62-3 DetimedrastbusinessiuMite. - foe osm soars sss ye coments 40-8 55-3 Stone, architectural cast: See Am. Soc. of Test Materials SS-S721......... 73-12 Stones compressivestress: 0,000 Ib. per sq. mM... 2.2 6s ose ces sees 73-11 We MOUBMARTITAN DEUS, oy. cece. dass ge boo os a oR smn eintne ge M a eS 73-11 Stop :— EEIAINOUEM ch | acc nes aah s Jaws os 2 Sire whee maeeeeAe eye See 13=25 (Come hANCHOI..¢ 6 Bese eee Oe POs cane 6 aera ranean 13-25 43-11 Tin WtettSin?,,..s « . sake dese Greet ave ac eae oe eee ens on Din Ar reo aor 13-25 Wiolationser ayia est ses Bs eee eM oe 13-25 43-10 Wierkecombrany tO Permity: occ... cee tuts oe een AN ek eee 43-10 Work contrary to plans..... PT ee nec RS Rtn. co Toe ee tc, Ge 43-10 Workem~ violationi....0-..4---.-- fA dee ais eee es 13-25 WineGkini Geen cise ese Sake © a. See eee cota? 13-25 43-10 43-11 STODSMGOOR tyne ei aac: - A Sid oe aes etme RCNA ok 69-29 Storage Building :— ISUSUEST DING Ge cease wnee Se beet adr ete SE dhe ee See 40-10 Posten TSOSeS st eae ee ree rare eee are aren ar caer ae) 40-10 2 story fireproof: Unlimited area... ROE re ne hs nf 50-15 Mstacy, other construction: Unlimited area... ....... 2. /2..545-e0e; 50-16 to 50-18 See Business Unit, Chapter 50, Index Summary Storage Restrictions: ‘Combustibles ...... 90-27 149-5 149-6 Barrels Sawdust Boxes Shavings Lumber Sisal Prohibited locations Straw Stores:— Ganacityacton. basement, (50...) .mra piers iyeyalsyapsinw seeps Hated a Spee Gm 62-3 Iara Tikoreyy, Sista oe soap teteeegete Meenas 2 Cai PRR RANE Some RIE us 9 62-3 RUSE DEH OOTS OU Weenie tic) .F.. eae aa tmEn Tn ig GeteMetey oes OSES Sheers: Nic Pataliae 62-3 70 Stores—-Stresses GENERAL INDEX Stores:—(Cont.) Department store: See Chapter 50, Index Summary General . os seco 0d oe te Se esas + 5h seh BOR Fa Bes, a eee AST ee 40-9 Market buildings... 2.4.4. sco. «aa sengeceonei: ioeinetey ae Se eee 40-9 Merchandise:shops.) 9 o)s sec ectjeu seis ca ods a base eine se oe ee ene 40-9 Retail o.a0 6 Meese aca tite st 2's 0 suse 2 doe veteieetar pence level e.6 eee 40-9 Specialty. iMag oes sae Neoeaie « ete Rated sa ceie oie es heme eee 40-9 Wholesale oy oi. 5.56 cc dtnea ha ole nares oct ea 1194 she Sih Giantess Benen ise Ge 40-9 Storm Door Inclosures Permitted :— 2 ft; wider than inner:doon. 2. sc. cs bck ots cswcds ch oe eee ee 61-87 A ft.,max. outfrom building face 9 9.24.02. : oth bs ent wee 61-87 U2 ft gheip bt limit Pee oe accra ektew ae race eee as em eee seeee ee gee 61-87 Story :— Défineds general, 22%. arc yet cos nels cee he os eee ee Aras Se a 61-17 Designation Of Stories. 222.3020. 25 ethers ee sia ees tee ce ee 61-17 First story defined :— One nearest grade, 1 ft. or less below grade.......... 40-1 61-17 Birstistory in paracey yess cers carseat ee 52-1 S21 Garage mechanism defined: First story part..................0...05- 52-11 Ground storys Defined: oa02 i060. necnae soe os eek anes 40-1 61-17 UES) sce svete gras c= utes Gos Ny Sie © Sted eae ee set et tc rte eee 63-4 Grade-takeniat upper level, . fo-..sa- cet ater 40-1 61-19 Street :— , Bond, indemnity. : 6.4.34. 0324 t¢e0e4- 28+. 2 04 Oa 43-5 43-6 Clearance of fire escapes for theatres :— I24t. above sidewalk, ~ sa .2ee0 lames shee ene aecien ae ool eee 53-80 DATTA CES 526. Sos es Pen ered eid edie, Gacyn. ieee cha, Shale oteee eee ee Nee eee 43-12 1D Ye chi\cc er ce ae ene in Sees Mire ees cee Ne Ser or: om a) 40-1 Deposit fee, $2.00 per ft., construction use tis. w wees ee 43-12 Derricks on sidewalks..................-4.. Fe eee 61-10 Fire escape clearances, theatres :— 124tt. above sidewalky << 0As..ta..O saat Se eee oe ce eee 53-80 Foundations encroaching.............. 45-6 45-7 71-2 Grade defined) 2222 5 ccscats Nestnt aan ceo tke seer ne eae 40-1 61-19 Obstructioné, BEES. 1, Ss. cj. Ss ss peo ey Co eee ee 43-12 BGrmiitss esa dee eitea a ety OE Se ee On gee eee 43-12 Occupation by materials. 61-5 61-6 61-9 61-6 POG tS osc iapcics aa eee tae Steam deen eRe eater eae eee ee ee 43-12 Red lights:on material piles... «25. Gees lesan oe tee oe eee ele ee 61-11 Storage of materials :— 4 of roadway only to be used. ......:..225.0.. bicitne gues Soke SSS 61-5 A’ fteimins to, tracks ee aes. t oc ee eerste ues oe etre ee aes 61-5 Littcclear space atcuriccc\ a wo hora: neste 6 epee atc kee Perea 61-5 Adjacent frontage with consent. . 2/22 22.2. nee ee eee token ee 61-9 Two level :— General } its ciieta eat scenic Peer 61-17 61-19 Grade taken.at upper level... 5 cnt sears «tee 40-1 61-19 Groundsstory = sco ss ORs s had rage eee oe ee eee eee 40-1 Ground Story commiimications.....< orkes 24245 rap ee oun saree 63-4 Warm: Oxitilev elec: bac Ss cdscs tcena-oaee, hte coo een os a 64-38 Wsesterminated)s :.2% wvecesges aoe gue ee eee ee 61-6 Stresses :— Bedrock: Reduced stresses allowed............ brpb greener pete are CURE 70-22 Buildings’ on bedrock 9" clei ota ose) ence hore a cee nee eae 70-22 Chimneys: ...¢. se.dae eseae ea ee ee cee ee: 76-8 76-5 Cold drawn wire: Tension ................... bP RUN NA a va 74-7 Columns? Timbers ..24 save ones gene etre oe og ele ee cea int: eee 72-5 Reinforcing steel in concrete...................-+5- 74-7 74-20 Combined live, dead, and wind loads................. 0c eee eee eeeaes 70-19 Concrete: lai. i siasccsciats Ere ene ee eee 73-18 73-23 Foundations to bedrock... 2... cc see se de-nn: oa a etahl coat ivecaa. 70-22 Increased stresses, shoring for construction. ...................05- 70-24 Joists; wood) .5.2)aiicee st is aun ene eet nn a cee e 72-4 Load:'60° triangle over Opening 2... ccc cere oe ene tists sietpstent esol steer 70-20 Masonry: Allowed stresses. 5 7 a axe sents ie cue eeouseauare teerors eh oe Sree 73-20 Materials: See Materials, General Index Gl GENERAL INDEX Stresses-Swimming 71 Stresses :—(Cont.) IDEAS 4b on ob bo eed SI ee Ca ea re 70-20 Oncmnessmasonnyawalls60-load-.-.-4--ec0-+a2e-se0-+<+5-eeee nen 70-20 SINGH, sos cy ova Su Se EER CoS ORE eee Oe ee 70-20 GOminiancle loadover Openings:...-....- 2-225. 2-s a26+eessees saree: 70-20 Spechl simMNcities, 25). Raenodeoenee cus woot ener ot oan ee ee 70-21 Steelpremiorcmp Hor ColUMMNS 2... .6266 56-6 joe ore Acdece sense 74-20 SUCH yogi att eo 6 ORION HRS 27 acre ARE ane eae ee 75-4 to 75-10 Gemaeall 6 ooo og cpa tcutad eo eR oe Ee Oe ee 75-4 to 75-10 Sima ill SRA. 5 See She ROMER een et 75-4 to 75-10 site reine OXULCMyIe re. .c oso. < exer ahs oA chee SAD elo ea oe Fetes 72-4 WIGS. 3. 66 5 ota dod Segoe ane eae ee 75-4 75-5 Wires Colditdrawn™ tornremforced concrete: ........-..---2+-0--+-+-4- 74-7 Wood construction, See Chap. 72 Sancemistain= Support cor treads and risers. .... 0a. ...225:0-+++ sears eee 64-25 Structural Engineer:-— Certificate :-— Ep PUSCURIMCLAINSERUGLUTES sap.) 56 o.5.0 cece nese ye hate oul Oe ae wena 58-88 Mecchamicalkammsement device... 5.625. .62c05s cee news e ee enna 43-15 Seria cree TACCLOMMEPONN NS5.5 soa ois Gite sso ycescne Ao aeons PSS Sl 72-6 BEI SSCCESCC CIN OIStSMEMey Factor css cies cle 2s < Gcceeets wi Se oimebee ae 78-8 Weldlngs Goncmll 225 e oon aceon eee eee ane am aiciahas 75-19 MintescaEsteeleloists eerie oS aah a os hare oe te eee ee 78-8 Cextiticationton drawingsrand design. ..:.-4...2.-..2c+sseuue snes see 45-5 Eenlemcnt-Onsdetermina tO). sc cel a< ecco sats Seep enemed as aurea 71-24 Seal OW, [OPTS 5, 5 9 a. aho 1S eC CRO ate oR Nee eee Serr 45-2 Soil Gasiss Gonsdily 2.38.8 Bane eee nee ere eee ae 71-5 71-8 Workingload!determination.....-:.....-..--::-- ee ee! 71-8 Wioodseradeycenrtitication. © 4. 5-00-22. 5+-- -s04-2as0- Rated Sa ee 72-6 Workin: GIVES, oe oes ele oe ea ON 45-5 Structural Engineering Act, State of Illinois........... io, ety? en 45-2 Simeturalewoad Beare, Mile... 0.2.2. e3es ss os eee ti Pe et 73-4 SinuctunaleN\on-load bearing, tile... ...-..:..:.::....s-n- Pre Perera s. 13-5 Structural Provisions of the Code :— Includes all Chapters except: Occupancy Chapters.... ............. 39-2 Chimp, Of 10) Obs 0.00% coca Ge tne De Ce eee Eee ren ay aro 39-2 Structures: See Exposed Metal Structures, Chapter 58, Index Summary Studios, broadcasting: See Chapter 55, Index Summary Studs :— (ConcketemuciMlOnrcedem mre ae sedaye sas sac na ie one ers ce 74-25 74-26 Woodmbearinosons prohibited: 4.45457 a---d.000ensseees eee ae 67-51 meses Sunde Ghyailiinya36 pee Sic to ae ite Comin wan ee pee 67-51 See also Partitions Study Room :— USARMPVRACLOE Ve. 6 2 os ois clon ceases eee tied on Dro, eee a eee 62-3 See Schools, Chapter 57, Index Summary Subways :— Building separations :— IDS AS ON AWalllls 5) 15 Se couz.etcia er siocduemta Nicks rsta ee eas ae ee 61-73 Wall to be 20 ft. max. from public space......... 61-75 Display space allowed on public side of wall ew 61-75 Doors: One allowed through display space wall... .. 61-75 Openings :-— Mit, gies DIG Oi Sela hob Pann aedns ju gdsecoedbe do dase ne 61-74 Floor openings: 12 in. wall inclosure required ee i ae 61-74 Doubletine doorsmequired) 5.25. 4--02.4- = eae cl NS eee ene 61-74 Railroad right-of-way under buildings . ST eee ee ee Med ose 61-77 Survey :— STAN eC CICUITG CM Ot ot cuta ss oss wc. ce PAE CUA, ROE ee Aare grea * 45-12 Showenewsbullding locations. =.= .4= seer ere isis ee PR er 45-12 Shamroldspusldings GmdOt; 9 ge: Me oe nice og wits oon tie eet oe steen he 45-12 Swimming :— Bavthm lati! in peepee ee aces ca carey Boe ee vaste a08 Do 5 SEN iene 55-3 INES gore LEITNS fae 6 ot Ba ore Are eRe bach fs o ICME ae 55-2 95-3 OOS ease ae Pema EN es at yeti acai a ik oo as REM ore Sed sie Wee Nh oe) aan 54-3 Gl 72 Tanks-Transformer GENERAL INDEX Tanks :— Fees:— ANNUAL INSPECHON : «cs... Sheed ee: otis ss a eee 46-44 46-45 Permits for construction og SHE ante an am tug eo eee 43-30 Structural supports....... Ss eR ren 0.3 6.5.5.0 9 43-30 Tanks, roof........ ibe cied, Ge piles hsteit B34 PARLE Shin Li ten Lee 43-30 Flammable liquids :— DIV WAYS: << cnn. Lg cdeei ds duis. ob Peake «shang genes eee 45-14 Generally. o.oo ee ee aes eee 43-8 43-18 46-37 to 46-39 | alert a [0)e eee ae ees eee Or PT PEE Do no oc oc 45-14 Permits: easy ere cig eee ee eee ea are 43-8 43-30 Gas holders, 5 yr. inspection required. . . 46-42 46-43 58-88 Imspection.:.... :..2¢.:2+ c.ee es bes - 40-44 46-45 58-88 Roof: See Chapter 58, Index Summary Taverns: Defined as Public Assembly Unit. : ......:¢..va.neem ¢ 22 Jue eae eee 73-10 Tests:— Elevators 79-153 79-181 79-182 79-162 79-168 | Shh gon(6(0[0} ne RE atcha mare Sica edit aes eae 69-3 68-37 Fires teStS se. cSt 5 ee eesestbis oon gueeb cess 9 Ware cars eos 5 oti Gy 68-37 Materials: According to A.S.T.M...... ee eS GS Gc 41-3 Application for test.................. Pan Ajit on be ane a eee ee 41-1 41-2 IMME thOdS =: =< acre cae atti e Shitria erecenessi= eer ey ses Grn eae eee ee 41-3 Mechanical amusement devices. ..............-.200e secu eteeueeees 79-187 Pile General... 245. ose e tah sts die Wane oe deca aes Eee ee 71-19 Metal. pipe piles’... - ..cecone ay de ahem aan « va vies @ og a eee eng 71-30 Methods. 5 5k 2 2 See on ee ha ea hel hs Be Eee ee 71-19 Required tests :— Jetted piles~... 6.5 2cc.4506 dae% itera oon os cote teen eee 71-10 Metal pipe piles.............. 0.000 c eee eee eee a Se eee 71-30 When followers areiuseéd.. . 3. cio ben0i sa toe ee a oe corer tee panes 71-17 Except: Drive lone ‘test pilé...j. 0 a ne cect eet oe 71-17 When more than formula load is wanted Sc Sqo. tio Dee pone 71-19 Steel beams \csdic yc fess et aepthet nhs ccs ay tne eee ee ee 71-58 Soil: Vol..25, Proceedings AtSah Min. 224.< as «0.004, arches ee eee 71-5 INTECH OOS =<. 2a. Sou She ha ee eek Shed 6 ote Dna tc aE Re 71-8 Thimble, ventilated: Around smoke pipe. .............. 61-91 80-10 Tile floor arches. ..... 0.0.0.6. + 404s due aese id cin Ree AR 77-1 Towers :— Generali (ig. 5 hin no oeie Fe Le Re oS eee Bent hag ee 61-55 Radio: Wind ‘load 30.b:per'sq: tts) re acd tea ee ee ee 70-17 Tank:-Wind load-30'lby per'sqeits <2... 5.5 Seu re eee Skee 10-17, See Chapter 58, Index Summary, Exposed Metal Structures ‘Erading?Rooms:.Deined. 6227 .ivanu a2 ta-ase ea eee 40-8 55-3 Transformer Vaults:— Ceiling height: 8 ft: minis.pon, asctts-iakds ayo se at arse SE eR eee 61-82 Construction: Inside buildings :— 3 hr. construction required! alll around), 2.2, 422 a a 61-80 Door; 60 min:, required’: ev. s.25 cok 2 eee © See eee 61-80 Gl GENERAL INDEX Transformer—Trussed 73 Transformer Vaults:—(Cont.) Construction: Inside buildings :—(Cont.) RRC O PMY PEPAMTCGUITCK scans hc conocer dove ncevnlnewebetereeeee 61-80 Construction: Outside of buildings:— SEMi-iKeproon CONSEFUCtION FEGUITed | «sass... ence c ees ae esses sees 61-79 LEGS Sane ae bod Goes Ca nices re Ere IE oe eae eae 53-166 Vents required :— TL @Glp JHE, TAMIA, CURES: aS :5 css eee ReaCAEP CHR TCL RIP a Sie oa 61-83 lsquunsinkareatomevery 4 gallons\oil? 2.) 52. sacs sccm. ens ee 61-83 Enclosure: 2 hr. construction required for 20 ft. above ceiling........ 61-83 Over 20) iti, 1 ine, Gone moe oon gmonapoodseounb ence ss one ome nne 61-83 Hhaustaventisystemimay De USed.. a2... jascee ek ee sess saece. se: 61-83 LUM REIHG 55 e645 O Ue ae eee eee 49-18 65-1 81-5 Trussed Steel Joists:— ANllonrgals Caner, oo odo ite 6 Suleman eee eRe an aa hee eee eee 78-1 Onietinarny Cong ANCHO oc ect ncne pOH Datos Home en nO a mnen ome mera ener 67-51 Nem inepLOOMCONSEUCLION. «...5..-065++se0e.0000% 67-26 67-27 ATI CHOTSERSATMELAS PINE SEC] SOU ls. 5% scvsicis ce cic hou do de ans aoe ed ons oooh 78-14 Beatin eel eel LOMEStCEl Anas suc csioes so cicrne cones domalersie ors e aes ae ok 78-13 4:10. Wah. 0 TCTs ee en ann eae 78-13 Bendinggstressesmupcoprchords').c).5 - 25 aid osde seco esse sass. 78-6 Bridging :— ID Balk AS HOD MAGNE? ut Sop pc UR CORON ead eisai aacare Home 78-11 Designtas per Chapter)/o, Steel Construction.........2.....2--+-.-0< 78-5 Number of lines required :— GlearaspaneaU pitow/eies NONC> 2.4 Bic. 0- es ce fae cence ears 78-9 Ower 7/ itt, to ibis Oneeeaancneda enon nonadnomeicioeauss odicdae 78-9 OverplApitmtopzilettemMwOg Mecca sis piecsis sig) siorpereieece oon sea eremee 78-9 Over lehtntors 2) ite WhTees )5 <5 cise cree ors 6 eis ve civic senslaeiee sas 78-9 MAN St elTAOISELCSS MANN oa eS she eithe Sara cacesiarsigie caved loa meine 78-10 Ceilings-slshoun construction defined 3.55. ..c- 5. se ee ase e ste en ee 68-23 Certificate from architect to Commissioner of Buildings............... 78-8 Certificate from structural engineer to Commissioner of Buildings...... 78-8 Connechions-srxpandedumetall 2s. \.55.k acces cs ccet es eee ested 78-8 IRGSISE GRECHIOM SURES; owe ne odie Go AD Gen DOS Oe ticg Bene amor price a 78-8 RIV CLS PRE agar PA eee Selabncis. sk Cee e ee eae ewe se ee 78-8 Wittnare strencth;:3 times design stress. . 2... 0256.. 0. eee e ee ee gees 78-8 UY SECIS a. 5 4.5 G6 gs BRO ROR RE CR ea oe 78-8 (Consinnciiion IaGke hous once op Conon nD Come enone eco mars a oboT 78-8 Eccenthicityatoiperdesigned fOr-ace a.4520e 1c esse cee eee ences eee. 78-8 BndsmusedsasspLrojectingybeamisser. -.0ht. oe oc cde eels ae esicleies ae ele 78-8 Erechon-sbearine) 24 in: min, onisteel., (22... 05.2666 ceceees es ecisle ces 78-13 ABs OWUMMASONEY A 5.606 56c oie) 8b .eieravele wis o 2 ee ba see ee wee Sind nes 78-13 Exposed: Prohibited: 1st floor, inaccessible spaces...............+--4. 78-1 WiberewiaheulmidityOCCUIS. 30 F.6 2 faite os sssode dae ees de nessa 78-1 Hloorssiyuour construction defined... 2.5.5.6 -esens2 ee ecceeetuecns 68-23 fiienmeaiate joists to be Symimethical . 2.0.1... .nanes0n sods oes hese ee 78-8 L PERE G SePMI es RO! I Os ck Sec oleae dee oa cy Gicns HEROIN eee a ae 78-6 Waleriscupport: Concrete Slab. . <2 ..6.s< ack a nna pedals oe one eee 78-7 (it, max; Sheetimetal*roofs: 4.0.2) ../.24) sae «eee 78-7 2 ft. maxes Wo00d f£O0fS6...:0.0:2 50. fers wm oon St Aces cate ee 78-7 Spans Clear: 32°£6. Mas « s<.cecewie dF e om Aes) nike 6 Se, ee ee 78-1 Steel‘standards:(A-9-36 A/S/T IM... 0.2 ds oe ha ies eo lee 78-2 Stresses as per Chapter 75, ‘Steel Construction... :..2....... 4am 78-5 Stresses in top: chord: 18,000 Ib. per .sq.im., Max.. 0.2.03... nase 78-6 Thickness of metal :— Bridging: systems: 2th in..2....0¢ cnn scees se nec ee hee aoe nee 78-3 JOISTS INS od. co dc aalbe cies BME ie) Ae oes be oe 2 ary cp Re 78-3 Welding: 2. oc¢ o. Seca dak nai wile reckllcnignn: cae Ao Ot eee 78-8 Trust companies: Defined as busimessumit..2: 2.2.30... css tc ent eee 40-8 MWNGSEPINNINS os once. noe Cosy tine tae ba Hed Bele oes 43-28 70-24 Undertaker’s chapel): ... 0c sssecem sccm n ees Gees 02 deity: ae ee Se Unihred-Pressure Vessel: Defined:...: .5.a:c1=.2 > sa.02 agy oe cee eee 84-2 Units, business: See Chapter 50, Index Summary Unsaie buildings or structures... 23224 20 0. q:steseasseeee 13-22 13-23 Vaults, transformer: See Transformer Vaults Vehicular passage below grade. is.....4222 vos 04+ os nei oes eee 61-76 Veneered. Frame Buildings:— Anchors: 2 required every sq. ft. of wall..... Sohn Seales tanh AE 67-64 Fastened to'studs..; ..- .. 52... sagmphecte 4 04 26 semis vs ane Ree 67-64 Size 2/10 SG. AN. cos cae athe by Ra whe he ee 67-64 Defined: Facing not bonded... fcc. ss.cnta cnc arssenanehens eee 73-1 Foundations, masonry or concrete required............ 67-64 73-47 Height='2 stories Max... ccc. 3 cc acc t:a nates cp edn nate ee eae Oey 67-64 SUSE, MWAKS) fee econ. ree ees reer ae uh ee ee 67-64 73-47 sPhickness? $2.10. MIN: o6o5 sa. cada eee Means cdcts ccnateles 67-64 73-47 Veneered Masonry Buildings:— Veneer is not part of wall thickness. ... 6.4 <2 4225245 o,0-:52 mec eee 73-46 Ventilation :— Additional’ required, special cases... 2 -.acee nt uate oo20 es aceite cee 81-8 Adequate air entrance: Exhaust'system). ss oc. 20s. eens a2: oe ceeateas 81-10 Adequate air €xit: Supply system ..c.05<.0-6 6: en..neees- saeco aoe 81-10 Administration :— Approval, Department ‘of Public Works... 2. ..2..265. sescsoeteseer 82-8 Board of Health...... 9-11 9-12 9-22 39-4 Detmitions;...s ce ac nae ae one ne tae ne aa mekaa 40-1 40-2 Employees: Div. of \Com. Sanitation... ...22. 4.22 422.9 4:bm are 9-10 Div. of Heating & Ventilation) secs <.se.¢ sr0dec ae «8s oe 9-8 Tmspection: after ‘complaimts:.¢ 3255 coc acs co 2 esses at ee 9-12 Power toumake ruless. 2. fei. ah se yee oo tee eee eee 39-4 Power, to pass on ordinances: «fap 5.)-ieh = oes he ted ead ee eS Yall Public Health Hngineering....4 25. sage: adjoining TOOMS.. 2-2... 2-2 .2c-e+e-4a+e+s-c-ss 81-15a MuscellaneQussroomsnmets seat aers. aetna ccs scion Ges were eu oe 81-15e OpeningsymesaAMe OOM. fase Sass saad Aelee eee es eons sae s 81-15a PA ECHGMNECOIMS sire ots ahd syns icine one ge ee SR eee we se eee ad 81-15d Bublicikitchensjand) serving Pantries:.- 22.22. -26.esese.ceses 5. sens 81-15b PAT CARO MOPEIIN fe RCEHNE Os tiacciay co aeeaca ce so Skee aaawioae yee tewecs tas 81-24 TCAs PAU xiATysOPeNINGS, NTC ATCA <= os a8 924442 boos oe le ne se oe 81-5 Skylights, max. open area, generally Reta etn ha aah tee ee ee 81-5 Siransomissiree areas Swing OO° MIN. +. 22. ece eee. de cece ee ete 81-5 Windows wInaxaODENALCAls sie csone ce oo es ats Goa ccm see is deca nn. 81-5 Maio AVEGHEHINGS PLCC ATCA... oe ees eee eS ek eee tees eee ea ns 81-5 asedeOneuserOlenroOMSirci..< 40-6 ci. soe cnss sile = te ae DFR OE toe se. 81-6 Canypliemes (230s, ou 5 home aon aor e abe casio Cotmenor an eres = 81-20 to 81-25 Dehnedestealthiulkair/conditions.... . 02.2.5... -+6 4-8 ees cess eee ue 81-1 Exhaust discharge point :— AW AVeTTOMESOULCE LOL SUPPLY. . o.2 sae 2s ne. Gece ness oes oeaeedae nee 81-11 (OUWUGOCES 5 o co's Oneness eee 81-11 Walltnotebemlusancencn. 42120. 53ancsouescne oe sone dance edecies 81-11 IND CHIEF ROOT. © cele Cok On EE eo Ee Ie eee oe 81-11 sRopmecinculatingasyStem)..) a5 40.5.5 -0-= aes one nee chee ae 81-11 Bchatts tpl Viec nani caleerer ste 1a cst jee fete ie yn ate Se 81-3c 50) GELIe Fh, (UST Th 00 81-7 General, See Chap. 81 (FIGL ICED SET REICSINIC |S Sain 8 BERR Oe 2 a ene BSc Soe ea ioe i 81-13 IMICES Boer eral mapper ee ace cree: since As Sitweiene Meese he sere see 81-10 IMigcemueall GANA J 66hi6 he eadia ae pO ore cunicn ooo aioe as oi ola cm 2 81-3c MOM eee SI GAESULPDLY Ee (oes) a ciai so ois 2 ies nis ole = Foe Glaus eae eleityee se Claes 81-3b MlernpuS-eNtecHAMical ExNAUSt. 4. 4. .j.05 6 oe De eben ees oe ee ances 81-3c Mechanicalasupply Aner cca: . ac. asie cot marie ent aia teen eee 81-3b INFOQ 5 618.015 0 RGB cute R I Ee eee ee cr Be 81-3a Bait call I APT ae eines cise aida distnagiaind as Avan Ee ae. 81-3a Onmenines wD erne dee ge pane ye ces clare eles Me Piven shar cose e a ae 81-4 CULES: ABE GILES Dy eewato cl tps ee ne eine ae 81-16 Oitlets#cencrale yee oesis eee ae ste sackets 81-10 81-11 RALUtMON Sees ES LOLVa Mel Z Nt aes Aces cre tieie seas wie itkeee Nese acleeeeeee 81-18 IPTONCEMONIFOONs EEXRAUSL. 626. oe. soe eee oe ee ee oe Note 4 81-7 SIETBIES o Sete GEES oa AGO ie 81-15d Redenean: OO LUA THN Sto oie, MR RRR gE Pry ED er one ai 81-9a Prohibited from CELtalneTOOMSnn parce Fen ene es ee a ee 81-9e Wihensroomsjarewinoccupledas .24accen-ss822 ss 40ss 0.6 eee ee 81-9b Requirements for all uses:— Baperalpnapetical list in Wable. co. sc 22,0 2.2 aes sadetaee cee eeeeete Sie, Cabistands-jgasoline Motors 4.2.20... 4442 oc Note 1 81-7 Passages inclosed, gas motor’ vehicles.................. Note 3 81-7 Projection rooms: Exhaust........:..-...25:.-5.6.0: Note 4 81-7 ‘SIEPEYSIN7 «SOR Ree rN SOIC COTES PEERS, Ee Re ee Se 81-15d ROOMS ehaGtOnyeeme ee ee ese ieee oa aes - Note 2 81-7 Mercantileestablishment..:....-2.0.--2-505+ . 9 Note 2 81-7 ING s o oS ee O OO CORN ren ia iite nic oe ha octets Note 2 81-7 WMO EKSHOD Ee tee es ohel resis ae ec a oe Note 2 81-7 Wiorkeshopetumes: etch) -5 am qe nds ane ee Note 5 81-7 Skylights Max openvarea to rooml.....-2-. +. eee n reece oe aoe oe 81-5 Structural requirements :— Imcombustibleanaterial throughout. ...-9-- 2 eae cen oe ee 81-14 Moisturemesisting, material np aaareeaee ciemeieee cee eee tance ae 81-14 SupplyaGenerale cr eer c ac iyeecce ia eee ieee a 81-9 81-15 VATA RV ULES ope eet esc gsiys aya) ce ays dolce ay nePeeae ole ape ts cs age Pict at VSO 81-15c (CHeckaroonisee rs set ccs n eS ot oat ee haat ee erg yen eR a da ae 81-15e RITCHIE ROOM sca Nc... MOR ae oe SEN oe Stee Caled owe 81—-15e IRTOTECHONMOOME yates seh cc sieht ack tees Rene ees ae PO ee 81-15d IPanitries eSenvin ey PUG dy. t...57 ch yteatecen ia eo Sie eee oe ont eles 81-15b Bublicgkitchensee teers cts ct oe Bin a tRA Tera ete he eR RES lke neat 81-15b StoragewvattenyarOOMs se cvctyn cer Serta aleve eslhe crac ac aine cet 81-15e StOragemOOMS e-pye aeuea Vechelrie ie ead Cathe hrute eee hs ohne 81-15e SOCUbIC Hea persmMinutes Mines pase see en teks) eee ae ee: 81-7 Gl 76 Ventilation—Wall GENERAL INDEX Ventilation :—(Cont.) DOSES oo. cies g waies ele Goa oie Oz arnciees oo Biche eal teye.e foe 6 Megslstd ayy ee ee 81-20 to 81-25 Time’ of Operation :.i3..f% 5 3s eso cecinscd aves aed Sate oft oe eee 81-26 Toilet room systems :— Exhaust connections allowed... cc. 2 .).0202006 2204+ qs Soe eee 81-12 Exhaust connections, 10% of fan capacity...................00000- 81-12 Generally independent?! ;. s. .cactactuoe 0 oki a's Bos Aes oe eee 81-12 SUppl yi sso4 v.00 areca c sidid avoaneulsie gies F ASiedia nes 5 4:4 aa 81-15e Transoms: Free area, swing 60°. 2. oi. ics0%a0.0deecdendet dene penne 81-5 Proportionate area, swing under 60°... 2... 0. ees oes seh ech ee eee 81-5 Uniform distribution, fan'systems.. .. 0c 0.002 oes cess os aaa esieeeeee 81-19 Uses, Various 10 ONE:TOOD .% o. ccc ce ecingien ee odes bees as $4iskeg wren 81-17 Windows) max. OPeN aLedi.s . vedic cian oe boos Pate cn a@etn seen 81-5 See also Occupancy Chapters 47-58 Vents, Smoke :— COVEN EG oe one occae ee cinders revere « As SPs oie Syereve eueleneltt oto asiese ass fane ence ata g ten Renee 80-13 Diamnpersis sists sce je-susisisee eer a/e aie ie Sue geee ehsie le «se. c.g Aceh mice ere 80-10 Gas fired appliances. 2. s.c.s ssn. 0 cies omong» $0 one eines sais eer 80-12 Generals << 35 isc.o5 o stis.c dase Shak SS eo oie Se iniete es silos antic /enefoia piousteeer oom 80-10 TMSUlAtION oe khong is oats as nes Sols eiae Neg s oo eee te Op ei eee 80-13 EAI GE os. 625 Ho dioare SOs cae Cop eioonsin nuns eulel ne vie es apy ee eee 80-13 Pass thru 1 non-combustible floor only................cee cece eeceees 80-10 Pass thrid Partitions... cag. cee ones oe eas sla wd ee ae 80-10 Thimble io: fescue os § Hees. na onal #10 b se rete ma © neers shane aisle | cree 80-10 See. CHIMNEY S520: hose ese a austeapshere ctcherehe «rove raceeaus tal uedsi eitay ate caer 80-10 See Heating Plants ; Vertical exit: Leads from 1 level to another....................ceseeeee 64-3 Vertical Shafts, See Wells Violations :— By registered contractors: 43.6% 37 000s sscne.ceenetetpeesee serene 42-5 Notices: Annual inspection; 30:days: cx. sis) <2 -tetscmm eres sptevle min a eeaek: 46-5 See also Notices, General Index INUISANCOZs. cee autene etal acae en ohare oie er ne ian eae ere neraaste 39-7 enial (hesitate tate ce neces eee ee ete 39-8 61-12 79-188 Permit revoked ccc 5 jas sse,siere sister a re cep one's ais els'aloshouste Pnavs,«)a1scs Cielo yorvel 43-24 PermitVOIGs 2.0 sie sane we pen cies ele tires tists © a cies eles ainsi are scenes 43-10 EOP ois cieiasn oe id wore a eiaeia We mas ee gia poner ae a ely ere 13-25 Pear GOWN ois sis cosors are bia ee wiles ee eels Gud one ondioe bie Gieiaaisn p aroayete hee 13-23 13-24 See also Ordinances, General Index Vomitory :— 1D Yih 1s ee eas Seo ca moro ooring Gorin ono coco o. 40-1 Public assembly units: 5: sc t = oe ous so aise» eXeusie syelee wieka 55-46 95-52 Requirements Same aS Stairs... 20 <.5.060006 0000s sens enwaoteteseones 64-9 Theatres: Generals ogc ones e is se dees ol eyes one a opsiels 53-61 53-604 Directional sign mot required... cn. eee woe 2 «ois e oe aie eran ee 53-193 See also Occupancy Chapters 47-58 Waiting Room: Capacity factor, 1S... . 3.2. ast enin seems meee 62-3 Defined siz tcc vedere ee oe oe rete ea erate ate oree er eek ts) etek Creates 55-3 Wall:— Arches: Depth, min: 1/12th of clear span..........0ceceeeeerseceeees 73-54 Laid on radius of:arch Curve. <2: < ¢ ccyeocce a:0/s05 2 ome oie ere Gistehnners orale 73-54 Rise, min: 1/12th of. clear Spansion «cai 0 cccsre cio alee ¥ dteesreermueperatatnce 73-54 Solid! masonry-.6.; alc. 5 6 ciclo Fan nre slsa cm eis crete olons tienen ela eyeasuetleneres ths 73-54 Wood lintels:allowed behind. ..... ..s6.c5065 tone © ae seveicneeeienstaters 73-54 Bearing wall defined :-— More than 1 story above its support... 2.0.05 cece ee net ees eden 13-1 Supports load in addition to own weight...............++--+eeeeeee 73-1 Bearing wall thickness :— As per Tables iciicccs sicg alegtieid ed ae os ai sivpsen sis salen og Ges era Naaiinee eee 73-28 Except: Basement concrete walls extending to Ist story............- 73-30 Below grade, Single Dwellings, 8 in. allowed in 2 story buildings. ... 73-31 Multiple dwellings, 8 in. allowed in 2 story buildings............ 73-31 Wood frame buildings, 8 in. allowed. ..............-2- 22 ee eeee 73-31 Bond of Masonry :— Anchors, masonry :— 1 Anchor: Units.0;:5 sq. ft. to 3 Sq. fle .... 00,450 copies eee 73-45 GENERAL INDEX Wall 77 Wall:—(Cont.) Bond of Masonry :—(Cont.) Anchors; masonry :—(Cont.) DEAN ChOrs MUMItSIOVeL:s) SGettatonlarsGe tte. esse esc. tos one ms 73-45 iPAnchorevenye4 sq. tt.) Unitsioverd2isquity. 2 ).-caoie:ss4..-5- 73-45 PEAT CHOTSHUMILSCOVEL 2) ft lOnGs anes nie Gels oaea sa. eee eae 73-45 Svaeg Ee Tit, TWaNNO, 58 5 pee tose CaP Oe Oe PERO ae 73-45 De Anchorssinvopenbackaterra Cotta. .s6 <. J2. scien ose ce sess - 73-45 rd Ckeeshead ercwpersisGeattenrs «asec «oe aeane 73-43 73-45 Every oth course a header course................. 73-43 73-45 Faced walls:— ANI EINOYES 5 0. 5.0/9) o.8 ort CREO oe LOSE ae tao See area 73-45 IBTick-wE ven ou course a header COUTSE. ....6c...06 sles vais seine se 73-45 Cast stone: 20% to extend 4 in. into backing.................... 73-45 Concrete units: 20% to extend 4 in. into backing................. 73-45 Stone202;;torextend| 41m; into backing... 0.60. 0020..-00+080000- 73-45 dterranCotta 207, to extend 4 in: into backing’.......5.0....:.0.- 73-45 IBS eRe DIRS SH ol, 0) oa oh eel ey oA Bien ning 6 ae BAU DEMO nmenne ae pe 73-45 Haein gaat Vax heleht 8655... ccc on ose sss foto las aereleie el a 73-45 VOM GWAUNItSR ES VelyAOLGICOUTSE:... «ano cocn os + celnecle au acs sens oe 73-44 IMA, GUGHT IG iiiys Boog acento een Oe IO oRase ae iene okt ete 73-44 Piers: 24 in. or less:— IEM@Ry GiliGmaaKs Golo nano BROS aan cha ana raa se dorce 73-45 iMaxamneedinot exceed: 20% of face area... ........-2-++-c0sseuss 73-45 Chasestomesimasonry required on 3:Sidés....0..5....5.005....60008 ome 73-52 Overp2 tenawide sare; OPENINGS 2.5 c..2cos es as oe esce ace tee cee 13-52 Coldiweathermequirements).¢ 2. 0....-.:ee0ncss esses: 73-56 74-8 Cornbelsse ViaxeAsineiromuaces ca). \ciecss cians cnc ccee sacs oncas 73-49 IMlasx, $4 vin, ie 1 COTS a SEES Rae EG ni IO A SRE 5 oe 73-49 BondwAltermate headers & stretchers's 2.5... 40...+00+n2e0e neces: 73-49 TIDHES COMURIES., TENSE ea ets ene ee PR, 2 a oer REE rcs 73-49 Wppericourse tojbeheader course............. 020500650 cee ee ee es 73-49 Haricontacts Mortar No. | required.........0..¢6-5.062ss+o0e s+ seen 73-55 Existing :— Buttresses» new, tobe builtintol$ in. chases. ...005.5....2..0-.0s0% 73-40 Canghesusedutistmucturallyjsound.. 225 ..j.cc ess «rcs nes secccdetee 73-38 Columns new, to be built into)8 im. chases. ..-....9.04.60:0-.--- 0 73-40 WA CIN Sem NG Wey OME MATE ratan feo cloe rate @ slceis che ie iis Slee ciciete oe sn oe 73-39 Moouniness So olcanea i ee ee ee ree en ee ein ae 73-39 Hoomnes mews combine withiold® 252...) 5....004.s20 ce eeseno anne 73-41 Montane Nom monly tombemisedin. -: 1c. oo ose 2 ete see ee 73-39 73-40 Eglasters- new, to be built into 8 in. chases..........:.2....s¢-c+-s- 73-40 Exterior: Lath & plaster required in dwellings of :-— Mirlan crave COUSLEUGHION: cacjccro< gti Gok ness 0. < PO Se RE ome oee ON 61-65 NWroodstranerconstruction. sare. sessce os. se uiiosie nena caer eee oon 61-65 IRa@atle [OMG do gone tee ere ce anne Eee ee go Berns 73-44 73-45 Bondedstorexert7commony actions =... .. asus.) eh os reece seeie ace 73-1 Facing: 3¢ in., counts only as one-half of required fireproofing........ 68-31 Facing towards openings: Definitions................. 40-1 61-39 Fire Division :— OISTSPUITCICULN er Nc a trt. Sik Oot oa SAME RAMeEe ction serene eee OPS 72-8 Masonry required as follows:— ene solideunits olibrick ct ene eet eee ite 61-62a Sunereintorced concrete; SOlidssc. oi erie cree blero acters ake ieee a eee 61-62b Extend to roof in Fireproof and Semi-fireproof buildings........... 61-62c Extend 3 ft. above roof in non-fireproof buildings................. 61-62c IMIOEATITEC IIe dala 2515 1 OL Oreste ei eeicereeeteie reais ates eee 61-62e Ofiset-walls;permitted:4 hx. construction. 2... 42ers oe 61-62c Openings in any one story :— ital owedmmaaniva CASE: \-2. cote ee ag eee 61-24 Required generally... is.5.. ssc « pdoma.p co ae ep eacnineee en BS Sate are 61-21 Gl GENERAL INDEX Wells—Windows 81 Wells:—(Cont.) Inclosure :—(Cont.) Windows :— MR PEPAGLCCUILC One t AA oie ns tee. eoe eee pees Sense cnet aoe nig’S dapsieeinn See Elevator Hatchway above Whip: See Chapter 79, Index Summary Wind Loads: See under Live Loads Winnders-wOnmenwidertntout trom center. 5...4...ce 2c cess +sccesess on: See also Occupancy Chapters 47-58 Windows: General :— Cleaning devices:— Required above 1st story, all buildings:— Except: Inside cleanable, reversible windows..................... Miultiplerdwellings, 3 stories or less ...64.tade see sae esas Sinclerdwellingsteprr ry striae ae oe eee ire eos a ices Wihentcleanable from! balcomtes; ete....0. 5.0.0.5. .0.-20csasasen: Construction :— MyM CAC MENON = TUS Ela re asters cidiers i siscve ee Se ieie cleicinuiye te eters Securedubya2sbolts, each) side of frame...) 2. s5.5-cas.02-see- Sain laos stay Glehon snipes os Dan oeaome nos oe oe nc od ee eo neo as Miro ucihewallivorminamer. tet sca season cacieeioe an einer oe Habitable rooms:— AN Ieee IL TE UUTTG LG 6 tc t.ctenendia lon cme a miGcetin.e ao c:hha claws cee on err o-cithe Glassrareas Combined 10%) of floorarea. 2. s. 0.2.5.2 54.00 sesseoes- NVA apt OES ciel taenes spies yee to cns, ses wise aie oe Sea eae 65-1 NV Atclithipeprnatriaeel et tee genset teeta she cece eee cicnseestisiicte. cut et oencrcie aes ea Mechanical ventilation may be substituted :— Bxcepisin-slospital:sleepingsrooms: 5... 4... .2s2 2624 0 easier Minltiplerdwellingss arte sea fcc eke ae arenenes oes SCROOIGIASS ROOM Spore isi, Stes eted staveucue ta cused a shayels el cpceateucasy Ses couse eR aCene Sima mleNd wellness yawn rts 5, cies cc dtvonatera rier iceieee Re Wransomsmused tor ventilation. ..2.....02..0.c0:4: 65-1 Wentilatingvopenings, 477 of floor area. .........2126-.+s-emeae doe Excepiasees ©hap ter oly. =p sbura ays iarcns tuo sei 4 aeh eee ros cos celscorene See also Non-Habitable Rooms See also Occupancy Chapters 47 to 58 Index Headeameitemupnto toprol Operating sash... fa0.c608 6. + see oe cee oc alkne Except: Casement sash: 6 ft. up, operating part, single or multiple GRR AEMLIIVERSS 2. lene ook 6 0 ord Hid co MO nS SOOO Ona Gee dae Mmultipleidwellings;6)ft. @im. up...............-- 48-59 ANGvallowed: Occupancy, Chapters’ 47-98... . 0-2-0540: 0820-042 Metal frames, wire glass, See Windows, Type A Non-Habitable Rooms :— (Class emaag I bis Oiso tine ancs soos ed seode onan acto pote cc. coteae \ Wicking grata lett ne 2s ne ane in eee cao eee ko coe Mine OS/Momiloormareamapren sarki ccs cca ci nas ei ae eee diransoms used for ventilation. .4..00:..0.-ss0me.-2: 65-1 See Occupancy Chapters 47-58, Index Summary Operating sash top: General, 7 ft. up Casements, 6 ft. up, operating part, single or multiple dwellings. ..... Multipletdwellings.6 ft. 6 insup: = 5. -5. 2%. 2-526 - 48-59 See Occupancy Chapters, 47-58 Index SLED, SS ate) 8 Cee aR MR ere oe eae oc ea epee cena eas ahh Oe Sills: Non-combustible in non-combustible wall....................... Spandrels: Non-combustible in non-combustible wall.................. PeTCONSEHUchON LOL Sit. Verticalidistancess.cnscceeie | eee a Mransoms ised for ventilation... 5296 sesso sos 65-1 Type A: See Windows, Type A Windows, Metal Frames and Wire Glass See Windows: Type A, Metal Frames, Wire Glass Windows, Type A:— Wasementasashtemaxer or tbs Oliteeepme eee aici aii iis eieieL ters Hramesrandysashes (Construction GetallSresm en) ns smelt en Glasceeeaineemi ines nepmeshtor lessen oe tei in) tee cere melas et. COMsETiction Climbs esis won bwlobwo agaat coe usb es ey no SO oko bo ouEe: Pe Cd eGeinemUL uve. ly iv Gane ee Renesas conte .cie Of Peon Seroe 61-24 64-36 82 Windows-W ood GENERAL INDEX Windows, Type A:—(Cont.) Glass :—(Cont.) Length; Maxo54:insexcept seeiGo=13 5 25. 5 4. ee eee ee 65-20 Mechanically heldanplaces. 2°... .2).< ts Gece here ee 65-20 Singlespanes Max: /20iSq.1s.5,0.-' toe Peco On oe ee ee 65-20 Width=54°injmax., exceptysee 65-13). 2 vi)... ano ae ee ee 65-20 Heavy gauge'steel, construction details.<.....<.%.. .enon seme. a eee 65-15 Prohibited foriopenings*overc0 squitsn- ct avers Soe ee nee eee 65-15 Prohibited; ‘single panesover 560/sqoins.....24 o.oo ee ee 65-15 Hingedrsashes} construction: détails? :26 22. «..°2 224... Seas 61-40 All-buildings over 1 'story:—=o).5.5 tke osc} os ens ceab ns Ge Sees 65-4 Except: Churches with double glazed'sash........-...56.:.500.0- 65-4 Multipledwellings, 3:storiesiorless® . 2 a.-2cin se Seo eee 65-4 Single dwellingsiany height. .... o.sa.h.cc eats > Sep dae ek See 65-4 16ft; alleyreturm; first 2)stories: 2 acs. see ss eer cee 65-4 Wood frame buildings.0 5)... coos os0 Aa ase oe one ae One 65-3 Locations :— Courts under 24 ft. wide: Windows facing openings............... 65—4c Windows facing openings in another fire area... ............... 61-40 Facing other openings in court under 24 ft. wide................. 65—4c Fire areas, within 9 ft. and 150° of other opening. . . 61-40 65-5d Fire areas, within 4 ft. 6 in. and over 150° from other opening...... Beis Pah ep SO eue CLE OR AOL HE et aoe 1-40 65-4d Fire escapes, windows within 10 ft. of............. 64-70 65-4g Garages; Class Ty crac.ckek oo aris ee ae stone 64 PO eee 52-35 In’ stair inclosures:Generallin’, 2.27 te. censors eck: 61-24 65—4f In required stair inclosures: Public Assembly Units. 61-24 65-4 In required stair inclosures: Schools............... 61-24 65-4 Except:\In-fhre’shieldistairsi. sos ca2as ye beet aet 64-44 65—4£ Over combustible roof: Within 40 ft. vertically... .. 61-40 65—4e Within:24 tts of oppositeiside ohalley 72ers. errr tre cr 65-4a Within 24 ft. of opposite side of easement....................... 65-4a Within l2:itsofidividinge lomline men we.s-nte ee ee ee ee ce 65-4b Within 24 ft. of and facing opposite side of alley................. 61-40 Within 12 ft. oftand facing dividing:lot lines 220 sae a ela er 61-40 Within 40 ft. vertically of combustible roof........ 61-40 65—4e Wood Construction, Design Provisions:— Air space: 1 in., around beams, girders, trusses: : 22.25%. se eds net eie 72-13 Anchorage of joists and. girders<= 2: -ccn'es ae ee eee eee 73-50 Architects certificate: Structural timbers “si: 4.- eter ee eee eae 72-6 Bearing: Beams, min: 327in, on wallss.2 emcee eee 72-7 73-48 Girderssimin?)3241ns ontiwallSaae nee eee 72-7 73-48 Onichimneys;prohibitedt)o*:.. scene eee ee eee ect 61-90 Gl GENERAL INDEX Wood Construction Wood Construction, Design Provisions:—(Cont.) Bearing :—(Cont.) Ongwoodlstud partitions: prohibited )s 5... 2505s. see esc es os he Pexcepemoinglerdwellingsw qe eeeeeemer rece ee tina. sss eae: RAM EICONS ELL CULOMMe ra re sco 8 ele pe uayset fas, usr Mewes as Gate es BenGin cas CheSSESMSCCMIADLC ME ariw smrsitar nyt ential rds 25.02, sense oe Boltedmconnec tions ,SeewlaDlen--ceisc cee easiest sis lore eis ok esc lae Bridging: Required between joists when h is greater than 3t.......... IS ALCO ROM CAB UIL AL Reet rayret sr cea saveunslvovokay sie T8) Bis Wier GIeRa dee See os ss aU 6 ft. max. when 2 LISS ORIE) Cay |e Rate chy oe Sete Re pei Ode So a ee Ftd bres i temmrea EU eall Bese aoe as tev gi ev orcs oa noes Sao RON Sree ee aA CESS MEA CLUS Seyay lc) fe lniahnvais che dca) s hue egies eel o oe Se Chinmeys:~bearing onssprohibited|. .. 5.0.02. .c.- 512-5: sees snes: Columns: Bases 2 in. above finished concrete floor Formula, 4 ONC Tap) A ER ees POE SIN he ao ee ey Rr ed ee (Wompressionsacross falls... 5.5. G. ose anise tse ee ees Table Compressive unit stresses, columns............ See Table DensityerOvannualyrings;pernche.... .. 1a 2. -n me ae esses) Seen none PESUTININ CLRW.OO Gear ne ree iencys Ce stele, oie teeontvs id. syebya des ede e] nehel a us TA End requirements: 6 in. masonry between opposite joists, etc........... OSS 1O-Oli og o CRRA ia ae ec ene eee ee rn. 5 EIReISLOpSmuraime sD WIldIM este weer se = eee bees oe eee ee Flag poles:— IDYSSS Vi. gg Rds pO eo ROO EO eee ae 72-17 Diameter of base, min., 1/50th of length... ...... et cee Diameter of top, min., 5/12th of base...... Quality, straight grained, free of knots. ... ys Ae. Wind load: 13 lbs. per sq. ft. of flag area....... his ee aed 50 Ibs. per sq. ft. of vertical projection.............. enc Blextnalmunitestnesses citer. cates en enieticee os eee et On clean ae Formulas, columns, + fromyZ4s tows Oss. ee cee eter ee ee Brann eenViIne2 ne trom chimneéyanya. 40.) - cei aoe ce eee. os aa oi Mines. frompinside of flue... «...5..7..+ 2 a6 ae - Be Oho et Grade certificate required :— Bending stress 1,400 lb. per sq. in. or over............ Beg. Cache ese Compressive stress 1,000 lb. per sq. in. or over...... Water Horizontal shear: Table of unit stresses........ Computation sdetinitions....... see. oe ae bps Te Ae Masonry between opposite wood members........ Cobia Cate ee 6 in. concrete between joists on dividing walls... .. ~ 6 in. masonry between joists on dividing walls............ Joists to be fire cut on dividing walls............... ; Modulustoise lasticityasbable... lst cmeereic santa easiest Partitions, See Partitions, General Index Rost bases; 2nsabove finished concrete floor..s......-+4.<-s+. sss eee ProtectedewithswatemStopSe..s eee ae ee Safe loads on columns = over 50 oq OVET SO... eee eee 83 84 Wood-Wrecking GENERAL INDEX Wood Construction, Design Provisions:—(Cont.) Safe:unit strésses.oncolumms'.... 152 3. wie.5.cp0b 10s os 00 Ose 72-5 SHOT oon, cco ticre dena tites Satine, ob scenes eae se DM ace rakeret et fot tea Oe 72-4 Span of timber: Clear span plus one end bearing..................... 72-9 Standards of quality, specifications. 2. .2........0. 20s. «acres cl eee {il Wensile unit: Stresses: . 4 4.c)s Garo ic n.3 caer nas dine pals ae ance wel de ee ee 72-4 Ventilation: 1 in-air space;strusses; fC... .... .ssacecnu es sa. 2 eee 72-13 Wood: 2 in. min. from outside wall of chimney....................... 61-90 7in., min. from.inside OF Bue, CbC.. 6s o 22 + sn od vs Fe are euesse oe Oe 61-90 Wood trusses: Airspace: 1 inch... f 2 2 cc cssclnd os bacctean anes Cee 72-13 AMNCHOLARES «aie. a sien re, = ESE DED SMES ahha oa eae Ake 72-16 Boltedconnections, Table.,.......;..o42c0..s oss sec us aes oe eRe 72-15 Garages, 2,000 Ib load, any point... ...44.02.05.0. scone ice se ee 72-14 General... ...5:05.. Sg disco pueselonie is ear eae) bey bla Sees LS 72-14 to 72-17 Heavy Timber construction........................ 67-39e 67-39 Manufacturing unit, 2,000 Ib. load............... 00.0000 cece eee 72-14 Metal’bearing plates. . 2. .< 6. ec os dene ns ses le wees ae a eee 72-16 See also Wood Frame Construction, below Wood Frame Construction :— Amusement park GevicéS... 25: J. taesscsmdananceeands 54-14 79-184 Area limitations! as as 22% fives « seq sti cie essere ore Staats OO RIA eR 62-7 Business:units: General 2. ..nc. cace8 = sa cctan sass adneawnasice ee eee 50-10 Inside fire limits 2.0.25. sone ee « a gein nctoe es ayes Sem agentes hee ere 62-7 Inside provisional fire limits... 23.26 2.2... 44 ve ssheess ds dae eee 89-1 Outside fire limits 453 eee 50-10 62-7 See Business units, Index Summary Ceilings My 322 oso caida oe ert ete Fre oe RIE eee 67-66 Chimneys, wood supports prohibited........ ee ieee 76-4 76-6 lie Poles 27.2. coco eee Pees een ee ee 70-18 72-17 Foundations: Frame buildings, 2 stories or less....................... 73-31 (General :37..4. et es Oe ete ee ee eee eee ee ee 73-28 Garages >(Class ET ae oye 52-4 52-10 62-7 Generalinges.c ox metic cc nas neee ee tee eee eee 67-1 67-58 Heavy ‘Limber construction ge. 25.1 erect eis acc ace eae 67-38 67-39 TCE OUSES Se hee tie ate ocd: cate. Se RTI eee Sie era ee 58-64 Multiple dwellings. 10 nae? oaeree Mec ce ore as Oe nae eee ee 48-38 Open air assembly unit................ 54-13 54-7 54-12 Ordinary: Constiictionga.ne. se ee ees etree et ee 67-49 to 67-57 Partitions: cs ete eee oc er niet aie ee eee eyene 61-70 Porches ee). ci ety ie eee oe ee eee 49-9 61-87 Shedse Generali... hates cc venti neh iy ne oe Ane cere eee AONE oe 62-7 MGLTEE nye actiosavkis kx maior sce Aaa eau cateeat paren hee Cree agate: cher ene 58-61 Adjacent to:railways, waterways, €tG:,< .. a32.6.<. «tts seeeeneeeee 58-62 Shingles. woods, ee ssi syn ciesetciel vee rssth gee eee 61-42 61-44 Sumgle‘dwellinig yc ssacnis e+ tela o's oye aletons foioieat ore) a ncn sem eget 48-54 AO) (1 (eR Gre Ve as Oo Ce Peace ee 48-09 66-5 Stairs :— Cues matin, ‘9 INGheS ieee vos sas asin eraip eee ie ee eee ane eee 64-31 Handrails... oicacat scteciae oases soars 5 os ola ete oa aisles Sigielore siotsetoreete 64-34 Inclosure TEGUIRED .4 <4. sce: cniegtig mae ste <5 o7 sed ace eee 64-28 [GD h00l os aR a ee rt eRe ri maccnemeney Senn meotags cocoa 48-54 Opén main exit Story 2.325.600 seoet os eee onesies eee ee 48-55 Pass: one stair toiget to 2nd exit...04.6 sens. oda feces Danes 48-54 Rise, max. 8} in........... Ee decree Megas eae tere ae tne eee 64-31 Rise times cut, not less than 70, or over 75%..% «/2.0015-ne20eemtenee 64-31 Through another apartment, prohibited................5:502e2000 48-52 Wholly in one dwellings. i... 000 cde ane a ceuk 885 oe nwa etna neae ye 48-57 Width: miny Sift2 in clears cocc.0 se eiseverre ces tetede oats = renal cloner ere neat 48-58 Winders: 9:ini wide, Pity Out; ...idscc sense iis ce mane e eee 64-36 AU iiohs(s een a Ae GG cic SECC Me Octo 48-24 48-58 Exterior walls, Lath and plaster required..............00ss0ecctesceenss 61-65 Fire alarm systems and extinguishers. ..............-..-seeeeeeeeeees 63-8 63-9 Fireplaces: 0% i:.c.ccnaindess « ees +s cicish oie seamless a5 Pontes 61-95 61-97 61-100 Fireproofing :— Over 1 story; less than 4.5. o.6 06 eoeneceedn tit bi oe ceo "ra tedape a ine is sete 48-32 Over 2 stories, less that: Ses ieee a2 sos v-tiait nid Rare cit eles eels eee anes 48-33 Over 3 stories; or over:44 fti...6i 500005 mh tain ees sas geishtas ees ae 48-34 Fixtures required: Plumbing :— Baths, lavatories, sinks, and water closets. .......-....-+ sees eeeeeee 48-66 Frame buildings:— 4 dwellings, max. permitted.......... 0. cee e eee e eee cece eens ee ees 48-38 Corridor type prohibited . ..... ci. c0e. sees io cosmo ny meme cael Rinmine 48-38 Height: max: 25 ft.iia 2s on.cd cane sacs aie Hie Sree ele doer 48-38 MOVES coo ons die 6 dee: sateinas igs aiavale'd alpine ed ansterO po ore Seer tment 43-17 48 INDEX SUMMARY Frontage—Multiple Frontage consents, frame buildings, provisional fire limits................. Broutace consents, moving frame buildings...............0..2..0n-.0:0- Garage, Class I, 4 hr. separation required............................ Glassmllerouhiseparation required =. -- 26-08. - cannes sass sce- Fireproof construction required when dwelling floor is 24 ft. up....... UIC AOOMEGCONEE Gc! oc Rak A. jective bie ao Sina deck enaes Handrails :— BOusid ereqeOMSChUcCHOnS sey cyt: sok sites ea files eee ind oa wees ee tisk Onemeqminkea sstalisrO COL NESS§ . 55 sina se sc ee cares cies 6 ailefore os etnies ees SE VORECUITEOMStAlING OrnbOGs hls. 4 cae ee ae nestiec joe donee cede nds oaen NA GinONAlTeCuUInedsStairs OVET/ fte....0.. 40402 s-4sccess occas esces IDrewlalle Inawaahiznll,, .. «aio rae ene Ree Ce ee Ie CORR ncn sea Heating separations, 1 hr: construction required.................0.0..0: Heating temperature to be maintained.....................- Deen iae Demo, KeNeallss coves aneoemares cocesmo Coen Useos 40-1 Di CPE reat ac fe nicks Sec wcies Avis ssisss ooh oes es 48-2 Lath and plaster required :— Ordinary and frame construction :— CerlingsBPPrE rete sc. coro Sees cose heirs oes be wee 67-53 JB tiGTHOre Wall. 5 ane EolGee Oe Din CINE ORI a oe eoG eerie te Lighting: Exit :-— IRsaiciiing |DUMIGMOGS. to 6deo SERRE N eR DUT AO SrA SeE Geena coOera oo os Ne walt! cing smepyewn ce ciac aeeiicpe oes sce ahs evclawelsteee at ele 66-1 Live Loads:— General :— Habitaple rooms 440! bz persds ites snc. + oc «cli. oes ctistere vice ste Rrivatenitilityerooms, 40) Ibi per sq. ft... .......c..0-.025-06+e- 05558 ubliclassemblyzrooms;, 100)lb: per'sq.ft..........02.02-00e-0eeeeee Up hccornlGorss LOOM bs pernisdeit.ccie ee. asso 56 ome sae sae cere sine ROOISwLON bag peleS stacey ss ayer se a ket cic, ave ar oreree evel vassaveie netarapomioee SDIAWENS WOO Masog ne sadanoes oo cd aes ocomononnanenato us oo6 Mechanical ventilation, not to replace natural ventilation................ Moving buildings :— ContonmrasmewsuilGin gsr meio. .poe a elas exsiclslie eae cone o sreraie auto rem eerehe Hranniespiiildingsw#o0y/o) Clause syacuyen are ainee oie eit orien eieecimnmeriec Hrontarerconsents, + trontage im block. 2. 2.30.) cm. 2 see ous oe Sele Oneslocationetoranothersse.. sericea Fe heise es, teller het aaa eens caries IPSINTIIKE NOES so a6 m Ciena eee Came bicie cinaict ou nila ind OOD cman cig aa Unicare Ge Multiple occupancy :— HD) GOTS HA COMMUNICATING. 1.205570) herersrsyel rome lake oe rasta case it oeistele seus etek: ldine DRC oes pet cease enon seen coo ope Daca Oe arabes AGA ceene IPevaiiieals oo ein aH 6 MeO DOOD OO. CaO SL cloo sro eee camara tooun menos Separations: Fire: -- Business unite2) hr. construction required!eec. ace. acseiiies aera ere Churches 2shr construction requiredaen aa coerce aie sere teys einen Garage Classil-4 brs construction required... 5..5-5-4-ua84. 6-0 @lacsiUeroshnrs constriction requireday msec eres eciciae ers Bireproot only, dwelling, floor 24 ftaupenc-+.- aceite deere - Generale ris Soria laeertiactine ctetioee cise 48-50 Institutionalibuildings 2:hr: constructions. «ke RRR EN buat SAN eee 48-2 Includes kitchens, bathrooms, cellars, closets under 40 sq. ft., corridors, laundries, mechanical equipment rooms, pantries, storage rooms der 40 SG gIt 5s 3s ol bon tsd kt Ne On > et le eae aan awe 48-2 Separations: See Construction Signs, Exit :— General, required in:— Assembly rooms over 500 sq. ft..................... 48-69 66-5 Corridor type buildings: <6. 6.06254 24 see asa ote os 48-69 66-5 Dining rooms over 500 sq. ft............0.....0.... 48-69 66-5 Wobbies Over S00: Sqyatee svete. cde nue we cease 48-69 66-5 Directional, <. 2c. Gates Meeain 44hb-bsact die saraees eee 66-10 to 66-14 EO XTG A 5. 5 AK acted ape oe aI on Mena sss Mee, ee 66-5 to 66-9 Bive BSCApe ie. + 2d nnaid de tata e pn eh ces ae homer eee eae 66-15 to 66-17 BIOOC WACICA GIG Ss oanghar. ane oe de Re is wine ee Cae ee ee 66-18 SRVUOIES oi. ioc hcg hala,s sce Ra ass Peas se we Meek ee 48-65 65-21 to 65-29 Sleeping stalls :— Aisles lead GirECE LO EXIStS. 42.2555 bye sie, Sone nee ee eee 48-46 Ceiling Ott. required ee 2.8 sac ee tense eee eee ce ee oe ee 48-46 a0 tn. clear height above partitions. 0252.0. aay . ese een yin 48-46 Glass, 10% of floor area of room..................... 48-46 48-59 Special provisions govern over general provisions.....................00% 48-1 Stairs: see Exits Standpipes, bldgs. over 80 ft. high............. 0... ccc cc ccc cee eee 48-70 purvey. OF lot required’. .Amyeea. eee cia aes ys ose 2 eer 45-12 Temperature: min. to be maintained... . 2.04 6.02.42... s005 aaechesen os 80-3 Vacated, ordered to béc sc... eee 44-7 Veener: brick: a2. aceon oete «ace eee 67-64 73-1. 73-46 73-47 Ventilation :-— General: see Windows Mechanical) senetal’.a0.. sen ee oe ee ie 48-60 48-62 Mechanical, not to replace natural ventilation........................ 65-2 Walls, exterior, lath and: plaster required... 3. ici022 Side veteeaeos: 61-605 Wall thickness)... .coesese ata oes ee et tees Cees 73-28 to 73-31 Water closets :— ACCESS) tO Wiis, 2a es. wos nl Dine ace Ted 1 oe te eT ore ne eee ete 48-67 IN UMIDE Ds, o5.0l05.5 oh chs ward aierans Susie sed eivis aoa oP te eee ee 48-66 Windows :— Casement, with transom, top of operating sash 6 ft. up................ 65-7 48 INDEX SUMMARY Windows-Yard 99 Windows:—(Cont.) Mistancesstomotline wis ft Mins. 6. oes oc Sone wre ve See ee eee ees ome ae 48-14 ESBOWEES TROCHOS 5 o:c'n ological Oe eRe ae ne ee ee 48-62 Habitable rooms :— HOG aclassnOmtyONNaUph an jase sn eases esbans- ee Ae aes 48-59 ALOE CIRO PELATCA Meee hired eres Vann shoes a vaceiafs sa: Su tia eels a 48-59 Lave Itine Gouri, IRF He, Molec he ogg nse ease nO ee coe noe Semele oe 48-14 Metal frames and wire glass, over 3 stories............ 61-40 65-4 Non-habitable rooms: min. 6 sq. ft. or mechanical ventilation.......... 48-60 Public rooms :— (Ganemlls 109%, GCS. a Siscetco ae SEOs Coan ee ne eee 48-61 Exemption: 6000 sq. ft. or less........ eS a Boer ee eer Oe, 48-61 SOAP EROUMSTOVEI4 OSE fitsacras © ccs aco uses eos obeasetws sneer canbe 48-60 Toilet rooms: min. 6 sq. ft. or mechanical ventilation................. 48-60 Wood lintels prohibited, except in Ordinary construction behind brick arches. 73-53 WMoodistudi bearne partitions prohibited.........5......2..00...e0 esses 67-51 SODERG, 5.0.0.0 2:6' 6: 09S olato 10 ARC Eenene 48-3 to 48-8 48 INDEX SUMMARY CHAPTER 49 INSTITUTIONAL BUILDINGS "WUE L LOPUO—AVVLOL J 00-001 | GIF'eh | 00-00T | 040'%B | 00-00T | GrEIZ | 00-001 92021 | 00-o0t | ec2'g | 00-004 | exe's Pot sivaX 4 Lopuy—TIVLOL “Loasy sod sos5ug¢ 6T- F2-9Z FIS’G €0-92 i RGGc‘G al ZL0'E 7 6 . i | i Bl tocar ashi tts st eis 3 ) 8-97 g' 10-92 Gg‘G 3510'S I-81 82-2 isu SERUM US) | (hse 09-29 CIS st | 80-19 LFO‘ET oe LG-92 6c ry | oce) de go. aS Pee TOUIION suveyury | ZO: 10: é Z0: ; ee = SER eee bet. 6 o ABO eeaaoE sueeyLTy sjesugt | 1é-11 O¢-OL | 2418'S | 9T-3L | G6s‘s Ggg G8: F CaP €¢-G OOPS Call cay eee ae 8 oo **ysTDUgT oplog | €9- GG. IZ TL: ISL. 19 6E- PS OF: CO. dle epeae, oo 52 mae oe ** 4904 *pAyjae7 apueebjooys . Jepug svepuly ae Ba “TWLVN es, y - Sos a [SSS Sa ne ee nant qe ; ae aa: tee lopug-—IVVLOT, 00-00T Pa8 OG | 00-001 | 984°SS | 00-001 | 890°GZ | 00-001 | 600'8T | 00-001 | 802°6 00-001 | Tos‘s fc" sivaX 2 Jepuy—tIvioL “Toosyiso soso 64:86 | Sor eF-9z | 932 Ze- 61 | osre | op-er | oset | ez 59° a ec Ghee C0 é ‘eplog WA Usp 12-96 | PFE | 16-76 | geo'er | cF-e2 ie 882'9 ger’ ee he ss oo Peetoraran suet IL-1 IPF. 82-1 LEF 9-1 | 22-1 vin Lire) Sees ae: “SUBEYLITY 8] GF-OL | #69°2 | 96-TT | 666:4..}.g0-¢ PL # LEP OLE BRL a LOE costes -UsT BUT 8-3 eh 93-€ | STS Z6- 98: 6! 98 7S ae “490g *pkjja0] apuvebjooys : J8NUQ sJepuly eby loouas Japun ee, Lees ae al | PID “AINA—NOINN J» jw |» | owe] mw [ow] [oom [ie feowEBE ae | [a EE Si ew Pe a SAG Si an. Pinata [pe Se a ——— - ULVISV ‘SOLLVISV —CY0OM LVVEddD LYM WIV. ATHISIMHO—9l Mav —NUMOdS SHYVADNVI TIVIOIGAO— 9ST 2T4VL "WLOYIOOA GT UO “PT “OT ‘6yT pure “YT “OT sorqry, Ul sutvodde somsy oy} Iof poxny aTfoqey, Ul JVM SURAIOA SIoJAS IP OMTRYAOp Joour o]jeqey opuUBLsS -I4Squs oq oloforoy} ppnoys seyqey pourolqns oy4 UI srejnoryaced oy, -SUdMOU UL opeyopuoseq om] ‘yopyUoO = SULYTOANg, oSOlyVISy ‘PeTOAOOSIP OOM uoryrndog ovisy ey} 04 SULjV[od SoINSY of Ul otp UBA aqysisdo W084 saoJAS Ip UL ., [BRISINPT ‘6 Uo ., [RB], VP9ISYFO “ SURNSURT BUOY ,, pure ., OSeNnBUVT] [ROW ,, Wooajoq Worsnfuoy U9SsN} SULIVAIOA WBA H[OAVD SV OYNOF JOYos ST OGG] UBA SNsUIG oIp WIT Surgpnser sxo0119 ureqzl99 “OEG] JO SMSus) OA uo qzodet ety} JOO SRSIOA VIP UPA—[VT-—A]T Joopyood wea arseyryqnd aIp VN jo—sonrnsury—A] owmnjoA Jo uorzRor{qnd sayy OF guanbasqng ‘VIVUad ‘ViVUa ‘HATVL—AL THHOMHOd ‘OHOVOONVT—AL AWN'IOA . 6 S O61 IMI G ‘VMIMAV-GINS NWA GINO Wid NVA 986L ‘AVI WG ‘VOIMTY HLAOS JO NOINN Ghd ONIMIOAMA AIG NVA SOSNES AGSAS WId WOO AV ISUHA 3O NOILVINdOd ZHL JO SOSNAD HLXIS AHL 10 LYOdaa / 4 _———— | ‘revg 2 Jopug—tvvaon, 00-001 920°2T | 00-000 | e648} 00-00T | sae's | “**"*“steax 4 TOpUQ—IVvIOL eT EERE) ¥8-9 GLO‘ | G-8L | ocr | SL-4r | OSPF Poypodsun, gop lagi MEAS oss) 09-29 zeo'er | 26-02 | aox'9 | 62-02 ose'9 F * "TOPO NT. “SURONLTY 10 = = = = = woos sUUeR LTV: “sponug, 0S-01 ogg o8-F ra £6-¢ 09F oe 2 eye peg eg. 19 68: #8 OF ite woe *"pAyje07 apuseijooys ‘eBy joouss Jepun, J8pup suepuyy uesp}yd : i 7 — | —————_—— “i avEf 4 TPUO—AVVLOT | 00-001 | FS8'0S | 00-00T | 9BL‘Ga 600'ST | 00-001 | 80G°6 | 00-001 | Tox's J ~~" “Stax 4 Jepun—aVIOL Moospisasosng | 19-82 | Gro | 64-82 | eapi, Osts | OF 61 9%-60 | P69'T peleieiestissa) “8p Wea uaa J OP-cG | GARG | 12-99 | FEF FL Leo'eL | 84-82 GI-€1 | seb9 27 TOUITONT ssuveyyy | GL. 1 888, py Ith RGG 1B-1 9G: IIT DONA E ‘sfesag, | 6T-11 | e69'¢ | chor | t69%% 606 bh 98-4 BLP. SS MEE ASUS | PSUS ETE I SS | tae cor | OR 86° 9s Bena Aron sadn “"qn0g "pAyjoe7 epuvBijooxs ‘ey jooy9s sepun 4apuQ suepulyy uedpyyd "SINN—NOINN * low te lef se [owfw | ow | «jw |x | ox r “pio greidoy “9UuOSIog “SOMTMOLA, *‘SoMUeyy "QUOS.10, “soyquent “mayodg Je 2B, aaIswo “SUOSIOg. “SoyTBUIa “sorely “"suOSI9g “SAT UULA ST “SaTeTT sgasensueyT [LOWO “IVVLOT—IVi0T, “SONVIGLIVIE—TVUAYL ‘GFL NAU—ANV TFL WASAVIA—Sa)Va GLVISV —daOM LVYVadt) LVM WIVL ATHISINIO—2LT tWavy, “SOLLVISV —NAMOdS SHPVOONVT TVIOIGTO— 21 avy, ele 1) $18'S 86'S “Jaaspisadsesug—poyroodsuy) ] 958'9¢ Sie'e) ovo'el * oped Wa wea9—TOUPION yest esses s-(paepaofacz, apuazInsul) TVLYN—IVVLOL, 2 & t SieATe ey “oo ssaeeyLypy Z16't 218° Ges’ 52 0 S[odagq—ysnsugy BOON OG sree esses s(purmng Supnpour) TVLYN—TViO., £l¢ 12) eS) Sys hs “oplag—qyog “IVLUYN ‘eek ASAVIA—aT)Va ; Writ OE2'S WISWEG Perper BIAS a pi Ua ae -roasytsadseaa9—payroadsmy, | FLb'92 209'€1 29831 Batak: = Dent ean eae Shs Goa “*(puRpaojao7 apuozmysyn) TVEVN—TVVLOT, 2 £ t pee ion oseRr gs 258'b £822 GlS‘z “+> *“sTosug¢—ysipau i SUPT OY BB o sores s-(paRnyng Surpnypoxs) TVLVN—TVOOT, ele 02! es) aes vores eprag—uyoq “IWLYN Sl ASACVId—TOVa 6EP Jgasyisodses0Q— joadsuy) ft ) LLL'T “-Oplog, UBA WooF}—rOUJION = copanenan UR EY LIPY : # ‘ 611 “**"sfodugy—ysipaugy ST sees oprag¢—tyog “IWLYN - = = J = = = — — “CEL ASAVTIA—WNVA ‘d AS a ‘WwW . “piom qvvidoy 4RAa areq, of “yNqsiq Us OISMTAOTT “aye y9H— siaquun yy a LY: ‘uoyods sadensuvy yeowo “QOLSIG PUB eoULAOIg - f-4 1apug. adjsooJ—'sIvax 2 sony, “THOM LVVUdH) LVM [Pde] Ul em Sueasoa sxozds sUOM Apaytopnosaq or¢y ‘AT 1? ViIVaa [TV.L—AT T IN ¢ “WMIUaAV-GIn SNISTLO AS Id NVA $0. LS «se 8B OYNOF TOY ad “4 of pyuo NWA ATV WIMISTATO— 91 Lop 4 ny an ¢ GINA. iS Wid a rr—t—— SOLLVISV ILA, ‘6T pure “LT ‘OT soyqey, ur -14sqns < IOAC [ WBA SnisU —NAMOdS SHOVOONVT TVIOIHO— 9f 8tavT umvodde samnsy ay} tof poyny LOY} PHYS sopqeg pourolqns oy} ursrepnoy.zed oxy, Ip o1oM uoryendog onvisy oy} 0} SULjLpoed Somnsy oy} UL TT oop ,, pue .asensuuq [emo ., wooagoq worsnzuoo SiOLIO UIL|TOO “QEG] JO SHSUay oy} Wo yrode.c oY} “AY ounjpo, JO uovorqud oy oy yronbosqny VIVE “StHOVOONVI—AL WNWOATIOA ad NWA ‘986T “AVI WS “VOINTVY HLAOS AO NOINA ABD MOO NW ISUAA 4O NOILVINdOd AHL AO SOSNSD HLXIS DHL AO LNOdAA “00% Taste 19.—HOME LANGUAGES SPOKEN—ASIATICS. | PAGE—BLAYD SY 166, LIBRARY OF THE WINIVERSITY OF (LUh HOME LANGI AGES—HUISTALE. | (Other i Buropean | | b P | Sex. Indian. Chinese. | Japanesc. |Languages., Other. | Uns. Under 21. ; stile Total. ‘amil. Hindi. | Telegu. Gujarati. Urdu. PAI | Tay | a a ae ee Ander Sjinees. | Japances. | Buropese Ander. Onges. Onder 21. | Totaal. i | | Indiese. | | Tale. | | | \ | UNION—UNIE. | { | / { = : Wh PN Gosconassoecscoo0sae M. 27,190 18,838 8,008 12,882 1,422 1,701 | 130 276 43,144 36,548 79,692 M. Stedelik. IN, 24,631 16,371 | 7,100 8,371 1,012 961 19 207 41,039 24,863 65,902 Ve Vay 51,821 35,209 | 15,108 21,255 2,484 2,662 149 483, 84,183 61,411 145,594 P. 3 | | | E ‘ Ui tisgescescapsevoadscon M. 16,380 12,953 | 5,091 2,576 1,045 57 | 1 237 | 24 63 225507, 16,952 39,459 M. Plattelands. — Vy 14487 | 113603 | 4/539 1,885 918 21 =s 7 176 | 15 40 | 22453 | 12185 || 34638 |v. ‘ P.| 30,367 | 24556 9,630 4461 1,963 78 | it | 413 39 103 | 44,960 | 29/137 74,097 | P. a = | oe A > OMA Tsp teteete rr M. 43,570 31,791 13,099 15,458 2,467 1,758 131 | 2,496 131 339 65,651 53,500 (19,151 M. TOTAAL. 9 39,118 27,974 11,639 10,256 1,930 982 19 2,051 78 247 63,492 37,048 (00,540 82,688 59,765 24,738 25,714 4,397 2,740 150 | 4,547 209 586 129,143 90,548 219,691! CAPE—KAAP. T ] 7 ] 7 (Urbanterr ester eee M. 1,168 730, 52. 1,128 | 1,019 312 670 | 7 1,224 26 128 2,446 f qr. 1,026 269 15 565 | 310 OL 406 16 945 11 70 2,069 P. 2,194 999 | fl 1,693 | 1,329 403 1,076 | 8 2169) 9) 37 198 4,515 Rural gemeaee ee ee M. | eon |e 23 | 16 = 8 | et 05) | 3 9 79 E: 25, 8 | — fi 5 3 2) 4) c= i 55 = 2 69 12 69 | 43 => 30 Ait 3 10 | — 120 3 11 148 = i) = TOWN nscsaxse8 M. 1,212 765 52 1,151 1,035 312 678 1 1,289 29 137 2,525 Pr. 1,051 277 15 572 315 94 | 408 16 1,000 1 72 2'138 ie ELE 1D, 2,263 1,042 67 1,723 1,350 406 | 1,086 33 2,289 40 209 4,663 1, i \ } \ Tanet 19. HUISTALE WAT GEPRAAT WORD —ASIATE. SY 166, 3% = = 7 f TAGES—HUISTALE. | ! | European | y | Japanese. 'Languages.| Other. | Uns. Under 21. | Ay ah Total. } | 3 Japanees. | Europese | Ander. Onges. Onder 21. Totaal. Tale. | \ ; ] INIE. \ = | i | 130 | | 107 276 43,144 36,548 79,692 19 | 63 207 41,039 24,863 65,902 149° | | 170 453 84,183 61,411 145,504 1 | i 20 63 22,507 16,952 39,459 — | 15 40 22,453 12,135 34,638 1 | 39 103 44960 | 29,137 | 74,007 131 13f 339 | 65,651 53,500 | 119,151 19 78 247 63,492 37,048 100,540 150 | 209 586 129,143 90,548 219,691 AAP. j | ie jp epee || 26 128 2,446 | Gaz 16 | 945) 11 70 2,069 | 3izaa S37 25169 37 198 4,515 | 10,198 = 65 | 3 9 79 | | 205 = ij = 2 69 | | pe — | 120 | 3 11 148 310 | = | 2! 17 | 1,289 29 137 2,525 | 16 ‘1,000 mn 72 2.138 aes 33 | 2,289 40 209 4,663 10/508 INDEX SUMMARY CHAPTER 49 INSTITUTIONAL BUILDINGS Includes the following: Generally with medical care:— Childrens’ home Medical unit Day nursery Nursery Home for the blind Old people’s home Hospital Orphan asylum Infirmary Sanitarium Insane asylum Get Commissioner of Buildings ruling, when no medical or surgical care is involved. Amphitheatre, teaching: See Teaching Amphitheatre Anaesthetizing rooms and equipment :— CylindersicontaimingseaseS-2.. 2... occas ors Some c cess eee see asne ter ID GOS. 5 02 006-0 60.806 BIO SIEeTR ee ncrn aeenen eerreay Pe Blecticrconnectionsand erounding. .. 2... 55. cs. ee esc s cose et eeeese ELE oc aa0 50003 CARO eee ne eer rere ae WETTING SIO, 5 6 oc’ che II REO INC ote RR ERE eg rn eee ae ANGCHOrLssoistarequiredevery 7 ft. of wall. ......... 0022. s250seeeseesee PAU PEDM AAUNIS HEE LOM NERD a. 5 5. o's, =. sesan's «5.0.5 4 atte lake a dy <4 Says Gt Siayo omens 46-1 to Area limits:— IeSLolnmoOuspunklemequipped=.....5.... 22.4.0. 4555 sync sees sanaeee Overmlastonyynot sprinkler equipped)... ...)..0..s.00s-0+s-esces nes sae Spmnkderedmel OOS wareasiMCreaSe... «.. 4eeo on SleepingmroomO ft.60n2 mines ..50.-----+ dee ee Neri cost tac Uae Construction :-— Hireproot required, more than 7 stories or 80'ft................... Semi-fireproof required :— More than 1 story and basement, up to 7 stories or 80 ft. high... . Ordinary or Heavy Timber required, 1 story or less............... ee Sshraconstruceion Over basements... aaa qsaeas ed eee ae ae Rorchesslastony, wood permitted: 25.42. .9.-e eels otal e acy Separations from :— Acsemblysroome:2) hr) CONStrUCtIONeeas sais as oe ers teen Business unit, 4 hr. construction.......... Se eee CA ee erate Churchy2snr constructions... soe <.aere = set pel ta ee Maultiplerdwellinge+2 hr: construction... 22. ..- 6 sree ieee oer », Openvainiassembly unit) 4 hr: construction: 22. 2...) ns se - Public assembly unit, 4 hr. construction... . eS. Single dwelling, 2 hr. construction................ See Multiple Occupancy Sormidors trom patients rooms; 6ft- 6 in. mins... . 6... ewe se cece wees Court requirements, same as multiple dwellings. ..... ....48-9 to 48-24 IDOE o0.8 (Re anloG8 Oe Mec Cen Diet One A nee Mena can eA ey Serine Doors :-— CORE RUCHOA, CATENIN IOI. 2.5.6 ocogooneid coven coc oadeyboecoen nese 104 Doors—-Live Loads INDEX SUMMARY Doors:—(Cont.) Forcible:detention, locks <0. 4... sis es. ta. ckee pA cel ene eee os 49-27 Locks, keyed, prohibited... ..... 0.0... 0c ccceceeeeseceenee ns Pee 49-27 OPEN OU. cc snrains tas ews «fis owen ete cee m.d eae ee 49-27 Outside, 2 min., within 90 ft. of any point on floor................... 49-26 Revolving doors allowed as extras only... ... 60:2 s600-.607503 cee 49-27 Sleeping room, min. width, 3 ft. 8in. between jambs.....—.......... 49-16 Width: No leaf: more than 4ft. wide. ....20...005:45..0:08:++5. Ee 49-27 Electric wiring, independent for each use............................ 63-5 Exits :— Based on Capacity: 00sec as «a sees a Son = eects Sass oer ce eee 49-15 Corridors from patients rooms. 2... 22.22 2022 nes ns ssn ares Hs 49-15 Court;1O ‘ft. min: width.2> «9200. ee eae ee eee eee 49-26 Doors, construction :— Outside rr. 42s ena ene woe. ct eterno eke aera ss eee ee ER 49-27 Sleeping room, 3 ft. 8 in. between jambs.......................0.. 49-16 Two outside required, within 90 ft. of any point on main exit floor.... 49-26 See also Doors, above. Blewht, 7 140 Clear, sdinncms ina ee eo oe eee esa. 6 Lea he 49-15 SIGNS on dee es ee 49-43 66-1 66-2 66-5 to 66-9 Teaching amphitheatre, 18 in. per 100 capacity...................... 49-19 Width :— Assembly rooms, lecture rooms, etc., 30 in. per 100 persons.......... 49-15 Corridors to patients rooms, 6 ft. 6in. min......................... 49-15 Doors, sleeping rooms, 3 ft. 8 in. min. between jambs............... 49-16 General,.3 ft.:8 in: in Clear, min... 0.7.4-.22- 4.6264. - +010. o7 one 49-15 Teaching amphitheatre, 18 in. per 100 capacity.................... 49-19 Exterior stairs, wood permitted 1 story high, ........................... 49-9 piveencmge ot: bictecl: 10) (- 7a ne ee io neem a OU NOS e en anne Ure: 35. 49-32 Fire alarm systems and extinguishers................... 0002 e ee eeeeee 49-38 49-39 Fire escapes on hospitals, solid non-combustible platforms required. ....... 64-64 Bixtures required; plumbing =, %...0c.4arce oe os ie ete eee ie eee 49-31 Forcible detention; Goorse ii: 4.454 .u,caneseeabans ake seen oh ncaa 49-27 Frontage ony streetwequired: ©. 2h... + si ec nee eee ore eee eae ee 49-3 Garage,Classi1, prohibited’ i225. face see ee ee ee 63-2 Hangar, non-fireproof: Prohibited with hospital..................... 58-13 Heating plant separations: 1 hr. construction required................... 61-84 Except: Those with public assembly space in same building.......... 61-84 Those with theatres in same building.....................000005 61-84 Heating: Temperature to be maintained....... 2... .2.. 2005 cee ee ces e ees 80-3 Hospitals :— ANASSTHELIZIN GE TOOMS: Wenge: oe sae Mo a ee ee ere 49-33 49-34 Cut Pmain AO sn: «Mees Me ae tho Se oaks See ee ace oe 64-31 Fire escape platforms to be solid, non-combustible.................... 64-64 Frontage COnsentS.2. <2. eet eee, ae sor es ees See a ea 59-11 Multiple occupancy: Communication on main exit level only........... 64-7 Obstructions in passages 7 ft. or less, prohibited...................... 64-23 Rise; max. (Fcc. see nate coe ee eee 49-22 64-31 Sleeping less than 10 is Single Dwelling. ..:.......0s.s03202%-se08 03: 40-3 Ventilation, mechanical, not to replace natural ventilation in hospital sleeping TOOMS.. eon2e eee eens be eee eee 65-2 Lighting :— OMAESI SMS vrors Bocas s Seite ae Hee ae eee 49-43 66-5 to 66-9 EXItSh ny Cerna ea 49-40 66-1 49-41 66-2 Multipleoccupancy 1... 2 saeco eee ee ee ee 49-42 Live loads :— Corridors; 100 Ibeper sqeit:. oo aa. 226 «Ano dene ocean nee 70-1 General fo hee 20 Oe o ae ee eee eee ae 70-1 Patients’ rooms; 40)1b.per’sq;, Ets... 002. aoae Gh «ass 6 oto aa eee 70-1 Public assembly units, 100:lb. per sq. it. 2.24 fancy es cee ee aoe 70-1 Roots, 25 Ib. per SQeft. <..jesii/d od ave nota pede < 62 oes e eee Oe 70-5 Wards,,40.Ib: per sq. ftas. ts. ae teas ss cn 2 acta eine © RO 70-1 49 INDEX SUMMARY Mansard-Standpipes Mit SATOCTOOLS ME sci. joi. «cs vacate ss 61-41 61-64 Mechanical veMmtMlatOMer.. 2c: cfc ASAs ng eto Sac ee ceweweawales saeweges Multiple occupancy :— ASHeDAI DIK? RODS. 6 Es ope Mas oO GOI ae Senor eee Ge ene ee Communicating openings: Mathshospitals;mainiexit levellonly... 74... <.s2.+6 +6026 -c0ec sess WWATHEMITSes whOME Ne eis ,cr5e er ocynccd eaiticwe Flctcqaleirvsia dyes Gf crs ce ane pee Doors :— Commiunicatingsmyhospitalss 2.25.0 see oes aac es os cade cesses (Communicating wath medical'school...2...-...--....-...--.2+.-22 Communicating with'purses’ home... .... 52... 06s fe ene eae ee es Conamunicatin Gwcy pes s.yacd 4) a. hens Ast da uo au ae se aeeee ibmersencyexitistairway, 49 min. door...........0:......5..+++-4- ICME SCAD CME Se © oh fire ohn oases St onsgar ss auateleeem Gace eet uence Setar ale CararomClassseypronibited s 2.0. ane. ato locate vies iverson este CATAL. o..5 6:05.9°5 AOE ee Een ne or 49-13 Ea ZLGOUSHUSESDHOMIDICEM: ~ . 5.0 en) e nthe Mh oa de eae so bss es soss cade Hospital prohibited with non-fireproof hangar....................... Hospital, communication on main exit level only..................... ILrelnininys, Tin GOING EES Sara Sado e Oe oO Oy Ture Ho Sem O Cees oe oem Peerage oe 2a Sos = oleae ow Woah at Res bane vines oe Bees SPILISLAG DSSS) Ni VT ea eee cee ae SENG BTA OAT) Sas Cele ay a ee A eer Rie On eT NED ARAUIONS MME: (460i ses oak os 49-13 63-3¢ slifeatrespromibitecdewmyr e atte nai ce eren ei eee eer Warinesmdependentior each use». 5-5... 2.0. 2-nceseos.ssseestes uses Obstructions in hospitals 7 ft. passages or less, prohibited............. Partitions, see General Index Plan approval by Fire Prevention Department required.................. Pim: OF lot mRawuieGl, sche soc cold on ee Ie eee rete e OP ie mnicoeeoos lambinestoxturesyreq wired: nc asyca gece a sow som oe aes ciee re meme oe Rorehesmwoodsplestoryshich permitted). ....0...2:...9:-9-+2+c0gu oes [Pdlalite Aseaaral hy Wines 6 vo cacao an Gees eae LIE om Ee oe pee Dat es ee Rooms, sleeping :— A\neel, IU Sa), Wey cE 6 non prose peemeES Goma Gra coolio eric toes F Collting Inert Oui) tpg d satne ees ee eon Hoc ess Seo Oem eee eae: ID) elitr cl prep et etcie PN of .8 Sedat agencies ue. c eeeee 49-10 Woorawmdth. 3 it. Sin. between jambs... ...22..c:2.n2.sneseoevoee eee Skylights prohibited in sleeping rooms.................-.0:+.....05- MirANSOMSEPLOMMDIteGen eco. sant, a ae ne ke ee Ome oh erase WOIEHDG 5 o sic o'er ORS Sera ORC ne REM ae mG er RONG eae Seats, Teaching amphitheatre :— Maxcel Ohinvagrowrbetweenvalsles...... 4... - ade seaeoscee susee eeu. Maxe omnia row between aisle and wall......2....:.--......2.5-+-.«-: Separations from other occupancies...................... 63-3¢ Signs :— Directional wicioh cs CO BS ae RISE PRS 2 Peak ees ck pie wel a 66-10 to LENIRD GXOTIOTS S306 cr VEN ee te Nee aE ES Mec Sty PAN inte ad a 66-15 to HlGorpindicatimamere iru tere cicero ioe AE oe Ente ee Wanrninomanaesthetizing/ LOOMS... © =... as a= 2 dees eee eens otien e Skylights :-— eshiittedyexcept in. Sleeping TOOMS..< 2... 00 ¢ ae dias «Oe ees nee See Skylights, General Index Sleeping room, see Rooms, Sleeping Sprinklers :— Carpentenishoprmcryhet: cyst nice actolh thas See Oh Te Pa EMVUTTNES LOT AL Crete tse ect cs seas es Sea MAD oo AI Sr adie ois ke aS IPED Na| El aV0) 0) er Susi ak Roce Sia RRR Peme Oicaeasdtth cd ogi ce hla Scr ter uel Trios oe ede FRAMES LOLAR Cormeen coh cw Wo -asasels gy cstcaretar Seka foree i elton ta oe ee Standpipes, hose and connections........... LA rts Cee 49-36 49 106 Stairs-Wood INDEX SUMMARY Stairs :— Based on. capacley). i055 - SLOLAcemInitanmO requirement; . .2% .-2.essceeee hs oee oe Hees ase (Cini iik® GCAO Ay ck Pepe oC Rae Ore mea tois oo reraintamic amen cert or 64-71 to Construction :— ANTGD, ITS «5g Frat ene Aree A NCI ee ROR eT Ren eae ent 50-14 to 50-20 62-7 Basement :— Ceilings, i ihe, Gonna, ps nosonecuGascocunods=oGouenadonatacc Pavtarome, I love, Cons ane WNe G5 oo cacedudvanscnasdscnnaGasanaonct Sales: Sprinklers or plastered ceiling required. ......../.0.......... Fireproof construction :— \Witen, Ger SO iealiitulie wen pe ead sete neds Gan dna nooce ss caenne beor EEXCE pS LONER ep toe Ril es ono lt coe Ghar eer ie ia, hole eee ieee : (Ovan uae (TRS ONOKe) II eate ig caine meow Oreo So BAe nT saonioe bok SWAN Semi-Fireproof construction; Not over 80 ft. high.................. Heaviyadimber=o0its to LOO ft. bight. 52-22 .. 2). 2 0 oe At ldsxeginus Salles pints 0) des debhlels io pisoecccdoaaeans bobs stocesn mae Onelinars7s Win tO Shite Ne Gocco GooneonabavamostG soenenoues : Overestonies muse metal lath aa acee im crer cei eee miei teestets seme Mezzanines :— IMR OIROLOH: BH aGl Sfsoov Nee Joponl Cobbs. Soa duaoadnsannduendcendpuguuede INU erapermitte dies a sitter wei on eiterhniecessneetae 50-11 110 Construction—Fire INDEX SUMMARY Construction :—(Cont.) Mezzanines:—(Cont.) Storagéibuildingss4.. 1.6... seeacetac ce nea meces sees see ee eee 50-11 See also Fire Division Areas below Storage and Manufacturing buildings :— Steel buildings; metal walls. ....... 0. .c....2 04000 ae 1 thatams | eee 50-9 Steel buildings, cement plaster walls............... 00.00 eee eee 50-9 Wood frame construction outside fire limits...61-7. 62-8 89-1 50-10 Courts: Inner si) i 4 ctecis «+ bo etyecie se Sts ore nee ie ate salons asm steeoe, eee e 50-3 (O01 cee eae ae Seer eae ean Rarer eRe ete eeke id's © on 50-4 TOP Ae 56.3 2 a ee orn cP I ee een ate eee 50-4 Dead 1l0adS ioc %.56-c.0 seed ee-svors ons yan toh pe Le ss ws |e we nee ereiia e 70-10 Doors :— Firé €SCAPC:s/i.6.. 52.20 de Mae eae ee oe hen See ae als oan On eee 69-16 Swing in, 1 story buildings 5000 sq. ft. or less...................0005. 64-18 Swing out; All other‘buildings. 2.4... c20.sen0+5 130s. omen ems meee 64-18 Electric Plant, See General Index Elevators; See Chap. 79 Index Summary Escalators, see Exits Exits:— Adjacent areas: General, 20.4.0 c.540 dead eee eee tse ree se Selene 50-32 Notzover 4000 sq ftie ch ies ae alae Be caesar e Siegen «oie. ie tonese) tence eee 50-32 Corridor:required to’ stair ... vc. + abe twos nee eee ere se «aes Hee eee 50-29 Cormidor.min. width 3 ft. 8.im..2 ccc sete oe eee at eee ni oe ele 50-30 Corridor, main: Min. width oft; Om. on... ec eens ee eee one ae oe 50-30 Distance to exit, 1 story buildings: Combustible:contents, 100 ft... -.4...ccae20nnenes send. denen-o der oee 50-31 Non-combustible contents; U50vit.... 2. iG.eae ee ac 6 oes cee ete Se 50-31 Distance to vertical exits:— Fireproof. units) 150 ftyeces wc Pac dG st os conn esr fares a) ages, ness = evereaneeme 50-35 INon=freprookunits100'ht.. 3.5 eve nee eer a ee eee 50-35 Storage buildings, 150 ft.¢ s% «<5 ccs eccnaerie ee acini ef leet nene ene 50-35 Doors :— Multiple: Each, mun? 2)ft:-6 Wisc. 0. see nai oe dans 2 alee Senne 50-33 Width: 36:in.for first 50 persons... 2... 2.26 60. sas Gerace des oo ona toe 50-33 6 in. for.each additional 50 persons... 0.22... 0<-+a6 es tee use ee ons 50-33 General stores: 22 in. per 3000 sq. ft. area plus vert. exit widths...... 50-34 Escalators, must be inclosed...<.0.- sees e sen ce nec nee Sener 50-48 Escalators details of construction:.<..4...4-s552sosceues es ys seeps 79-143 to 79-152 See General Index Rooms, more than 75 person capacity, 2 exits...................00005 50-28 SIGS hed: ard catia, hee tees 50-55 66-1 66-5 to 66-9 Facing; masonry: Anchors required.) ss). .coees sees ners angers 73-45 Filling stations, no drive into building................... 51-47 92=1 Financial unit :— Area, limitationscn «,c:-<.ccs cs pteee os ee & eon clei Ss aoe otis ey paneer 62-7 62-8 Area, sprinklered, 100% increase allowed................-.2eeeeetees 62-8 1 3H] 50-17 iRartitions) between tenants. ..........--.-.--+.+«-- 50-19 61-71 Manutactunme-sl story, area unlimited. ....5..........02.-85.00:- 50-17 Storacewestonysrarea unlimited .-....2.6-.0.55¢3- senses nce es + sus 50-17 Ordinary construction :— iprickswallievery oO}ft. between tenants.......-.......2008.5+000 50-19 antitionssbetween tenants. ..2-..--2..2-4-+e.-c+-~ 50-19 61-71 Manutacturing:l story, area unlimited...........5...:..0s0.0:-0- 50-18 Storacewpastonysarea unlimited 52.2222 -ccen ser se tev ese eset sens 50-18 Fire escapes:— Ec lonvae Oral term PemmMitte ess. pays sects = eccynie wesc oo Sy eis oss ereuare os woe sets nae 64-60 Clearanceyabovespublicispace, 14 ft. min......-..1...22.0:.-5. 0-225 64-69 Department stores, prohibited on........:.-...6:6+. 0. 64-60 64-61 Extenonwbermilttedias Stars. .: 2... .2. ote wena ees ieee en eee enue 50-37 (Con eral PR ce rei oye aie zeta, seis oe nL tere 50-36 50-37 In place of stairs:— Sit. width required for each 22 in. stair width..............:...:.- 50-37 May replace 1 out of 3 required stairs in buildings 6 stories or less... . 64-61 Mayenotsreplace Stairsim sales units)... 3. ccc. sees oe eee ons Je 50-37 Eronibitedeoverstreet MMe .as5 fostitears a2 selec cee mn ne - See te © omesnos 64-62 STEWS. 5 5 0-046 6 Hatt ee CUE NCCE eee 66-9 66-15 to 66-17 See Fire Escapes, General Index Floor load cards required, lb. per sq. ft. allowed....................505: 61-13 to 61-16 Foundations :— Cold weather requirements............ 71-3 73-56 74-8 CROC, 5 0.5 6.5.9 dibly Repo SEND Sie a ROE ene Ee ee Sirs cic carts 2 73-28 Soil§pnessurestallowedmermtis chine new ses tale oe ones house ot etree iii Se MestssomsollepnessUleste rns tucson ee ee eee 71-8 400 sq. ft. building may rest on reinforced slab....................... 71-3 ramespuildingster. 4. 2-66. scene nets ses 50-10 62-7 89-1 EIKOULA DEL CONSEM ESI as ery rele sene: corn oasis 6 cine ans ect c acon Wore ci clts se nieces 59-3 Gas plant, see General Index Heating plant separations: 1 hr. construction required in:— iBuildingsswithout public assembly rooms.......:......---..0---ss-+>s 61-84 Brildimespwithout theatresme js cheeses sees ciate Geis Sis poet ea 61-84 Heating plant separations :-— 2 hr. construction required in:— Buildings-with public assembly space. .....0.-...:-.....----++-4: 61-84 Buildings with theatres :— Noreladirics 4 Suman’. COOrs,. v2.1 toi aeniats aeteee craton Jehie weet 61-84 Invcludingey met Ac wind ows, Ih Amys crete yetars cease eae ee shetell de 61-84 Oca way from: any AUGItONIUM ; .). .<.jnie)- ote ety sce oie lS ees 61-84 Heating -shemperature to be maintained. 5. . i... 00. eee ee se oe 80-3 CERCEEATTIETACTORICS HO tee one eee ee eee 50-25 MMMM TRE OMCSCA DC We © oho os. Gian alge ot Oe ceere ge mrayencrattVanSIahe /ceg, tare ee or 64-77 to 64-79 Lighting :-— Additional required in buildings 3 stories or more....... 50-54 66-2 ID ETeG tion a lee eae oe Oe Ee ie ..66-10 to 66-14 ID sale SHEGOS o..ci Hal Gere ROC oe eee ees 50-55 66-1 66-5 to 66-9 PORD GREP ob G OE SE CRO tC ICIER TORRE Orne aera ert Sr .. .66-15 to 66-17 IN(ormvall,. 2 soe eRe tie Ae Ape ae reg In 50-53 66-1 See Lighting, Exit: General Index Live loads :— Combinedydeads live, and wind loads! =..0.0....2- 000.2. seers = 70-19 arEIdOrsne OUND EL SQaikoy o acieeas Fils seve scree e\uieels > cua ees woes 70-1 112 _ Live Loads-Office Unit INDEX SUMMARY Live loads:—(Cont.) General, s.cacg ste etn oY meer nie m Vows bey p Dd Ha a ee Se 70-1 Loft:space, 100 Ib:perisq, ft... cstac scee0. 05s: oh eG eon eee 70-1 Manufacturing, 1004b.pérsq.ft.. 00. ss cs vincs eas vie gs ys ee 70-1 Office 'space,.50 Ibiiper'sq. ft.% uc discs iweeoes eden ool see ee 70-1 Power plant space, 100 Ib. per’sq. ft... ......02 24. .400 22> 92) ee 70-1 Roofs; (25 Ib. perisqfti 2... seo noe ties ea anise.) dG ae 70-1 Safes, calculations for. 24.5.2... 0% 53. ad5e 04 se amnenneonces: ) to eee 70-1 Stairways, 100 lb. per sq: ft.c. <2 20200e8 see ots ee dae oe eee 70-1 Storage; 100Wb: per sa. Pts. Seose 3c fects coe ate cece oe eee Se 70-1 Stores, 100 Ib. perisqetts 4.05056 oc. oc sore ene ne sees eee) oe ee 70-1 Wind :— Chimneys and stacks.c..05.: 2405 oc0n hp tes ook ose epee eee oe 76-5 Flag opolesis, onsets, «suc autor mista caetenre se tere Oe vise tareacrs Shore eae eee 70-18 General Pee oc aaci eeronenee ne ae Oe oe eee 70-11 to 70-16 Slopine FOOIS. s/o e potunas ey eeyamem esas) queens Sa eeeus 70-5 70-15 Special Structuresicn.< sacs waco ans «Wied he ie epaaey 1 peck at eee 70-17 Load ‘cards: Ibs} per'sq: tts allowed... 2 ecko cho e 2. snes sto nee eee 61-13 to 61-16 Manufacturing unit:— Areas Limitation’ .2%:.5c0 ce: + wt: «hac au ate ie ae bene ee 62-7 62-8 Sprinklered, 100% area increase allowed................--.2+---00- 62-8 Capacity factor, 100%. fei: Mears 5 tn osc ere eee lecee se eee eee 62-2, (62-3 Electric manufacturing plants......................-. 40-11 50-12 Exitisigns, 3 stories Or MOP... 2. ae. ce oes cece se oe 66-1 66-5 to 66-9 Pa GCEOTICS 2.4 soia(aceavors avatars c Sctyons > tee ae Re nea cian ee ee eae 40-11 Gas plants, See General Index Generals sees, 54 Seige bid aenselare 0-4 A aSiahs AON Chaar ore ae eee) eT ne 40-11 Greenhouse +... nee ee tae eg eine ee ee 40-11 65-5 65-21 Live load, 100Mb. per sq. fte.... 2 te nee hae ene acres oyunu Ys ernees 70-1 IMRT Ss ooo acca hig, sigs cs Gildas ates dare zg tae rn ee Eee ne ee 40-11 Steel buildings with metal walls. <.2...0. o. -fe 6.2452 o-oo ness aloe 50-9 Steel buildings with cement plaster walls........................2.4. 50-9 Steam! plantSisscos.c0 OROLTO Bie aE Oca reece one en ere 64-15d Capacity :— Hactoms0~@main floorand basement... <<. o.2 262 s25---. see oa 62-2 62-3 Hactoro0Muppermtloors. 25 cen 22 cae shee ee eee Oe ee eee 62-2 O2—3 Floor area, largest to determine stairs.................. eee ole 50-38 (Gerieral MPN es co oe Geo oss HAS ele ees oe ee ee 50-38 SLAIGRUITNIES aees cece cyclo cities = Sic saa eS Rabon RCE Ee ee i 50-38 Doorways :— Pentti pesrise li Glosin a. COOKS's, 2). \.). \1s aise so hes eh ae es ae 64-15b Strecmexitehoons22 im per SO00/Sqittss 46 yee ae aoe eee 50-34 OOS Aotemarmaisle: mahi orn ee ee ee eee 64-15a WnFOnehncinrding WAS)... Js. o- sav piedoe © ye ace gelec ae teeee 64-15a ninesescapes, exterior, prohibited) 2-2 occas. e-ne - 64-60 64-61 Sprinklers :-— PAINS EMMEMNES esp see ences ee A Sere cre IC ety a redo er ena ere 50-50 unless: 2iStOrieS, OF OVEF..P. . sci4 oo 5s cytes is oe a wee ee Sere ric 50-50 Stairways :— TENSILE. Ate en ROE OP ORACLE Or ar Aaya SAS TO Gone 50-42 (Gomer. Ss ote Ole Oe ee nA cater ica one “ecto nd RETIN Cee 50-36 to 50-39 Inacombustibleme tiersorc + ac oes oe ee eee Rs eer eee 50-39 EME RSIceAy AS COLE she os ie tessa e Roney = otc sys reer ie ee at a Ie 40-9 SUED? TETRIS. ood ha Re OD Ee Oe OO Denn ia Hoes Petey RP PA cere 50-38 Signs :— ID Free aVE ahs cue: Asche toon, MO CER Gant ce ee Ge Kinde trey 6 © 66-10 to 66-14 Bai 6 ole boned boc SO COL: . Re ee eee et 50-55 66-5 to 66-9 PORE GSRSICE. Yc 8) an eng eee SR Mere sree ay rs 66-15 to 66-17 Bl Gorin dicatin gsc ecu stis ce ee Shey gs ener Mera ey seni uate Ree ee Rs 66-18 General: See Chap. 66 50 114 Sprinklers—W ood INDEX SUMMARY Sprinklers :-— Carpenter'shop'..3.3...5 scciacadm da < 2,54 «dopo cos So, aans ose ee 50-50 Department stores over 2 stories: . . . 224.20 fee os oe one eee 50-50 Furniture storage; financial unit. 0. 06 6 dee geste case ss ate eee Cee 50-50, Lumber storage; financial unit. ;.... 4.02 ov... eos woes cs deuin ee eee 50-50 Paint SHOP 200 oars.5 amen one cencim obama, oo naeee to hee ten 50-50 Paper storage or baling............. 0.0. c eee e eee ee 50-50 91-121 Stairs :— Areas: 3000 sq. ft. or lesS.c... 0s Secc fe ong sw a ettne a ee eres, he ee 50-36 S000'sq. ft.. to: 7000 Sq. EG ois cee ceo ate eo phen nein oo 9 de a, 50-36 Over 7000! sqiites esse ec oe ations ec a ono on elon eee 50-36 Basement: 2, stairs: required. 7.3.2. 4-4 c4ece+ ae) vec de aa ants 50-36 Bimployeessiawis. 05 ae ec a caeeeeee ees need 50-30 50-33 Inclosed stairs ys < .ice00 34. occ c sess oon dees bee 50-42 64-28 Open: stairs probibited)s ..<...¢ 5+ cavetacnes sagt sence mnedions oe 50-42 Buildings over. 26@ft; highs 4.225 ves sash dad dane ash deen c epee 50-36 Buildings 3 stories or less in height... ......:..% «2.04 00 sd a..0 30 0S 50-36 Department stores require non-combustible stairs.................... 50-39 Exceptions :— Blectrie plamtsie csc. ore reat oes ee 50-43 Gaswplatitts sis. Sere ave stat huh eee Sate eas eter Ae rae aes nee 50-43 team plan tae cat ope A cy ton ces ce Ooo Sree we ener tenet ope gence ee 50-43 Fire escape stairs :— Department. stores, prohibited'on . .. sccc ees Sheu d «ee fie nein Ssoidin eons bw ale Mees eS Ventilation, as per Chap. 81....................00005 51-85 Equipment :— Boiler in dry cleaning buildings................0..0.00..0 000 e eee Containers, flammable liquid..................00.. 0005000 e eee eeee Conveyors, automatic closing. .......... 0.0... ccc cc cee eee ees Dp tales sats acs a coPoe foal fm ys nae, Mee ate ence 2,2 dese tes & erly, 2) case Ducts, automatic closing. ........... 0.6 ccc ccc eee ee aes Dust producing, TOOM yee ie he ss ene ars, 2 Sn be be ees ata eee Electricalcapparatus:.ce cei vais 4 see ao faa caw shoe oe a ee Fimamnel lin oe) tee os eee ae Se ah otic Se on Hilling-pipeanduhose? Ma5.o ck te.ge leis becuse 2.8526 %yoo ccden sexs a eee Blammable.liquid’containersis veers soe oe as sat co ess Cee Gasoline; devicesis: 25.0, 0.000 ex.ge scans tsa etas fa thte o 5 4 Hie Ayo eDishn, amen E75) (Xe ga Lena a ae a mn ee ed rR Sonar Grain bleachers, conveyors and ducts... 51-91 51-107 Grain bleachers general) 2M 215 4 ete 2. oe cetacean cas ee ee Grinding T OOM a 5c pies teh he sta 2 Ee eee ee Heating :-— Dry Cleanings co.c.ted hos aos. 5.0) 2,.0.4-. SE er Saks 51-105 Fire division walls, standard... :. <<. i420: a2 5. Sessa tes ealen as General's:..4 62.06 nb.c0a tats eet a leo 53 TOR eee eerie: Seamber Gry kilt Sie 8 Accesses 0s a Hs htetsc! a oc SRN oer ease eae ae Nitrocellulose products. ... 2.0.2... .0c0ceece eee ees (129-62) Painting: Mixing and’ spraying...:) 2... ef). beset seen asee ne nae Picker rOOm. +..241G sive aral Babs aid hh qe eee Ore oe Shredd erro om jos jo)s vests ene eo eae eS ee nN ett ste Internal combustion motors: . 3.2.2 6c se. wane ee tees oe re caro JAP AMMIN Pes oes: A act eect a hae og? Cee ere PEE a mene Lumber dry kilns 2.52.5, 4.6...02.0 093s scare Te eee ae: IMOtOTS (FAS so 1 slo dev vw lveieie ueehele eo olates Ge ter ere One eee Open fireand light devices”... 4:0... s. 02 pens seen tL eet een ae OxVPen \CONTAINETS 4.5.5 ocialers die, qerstaseians oe ee mele te ee eee Piping; flammable:liquids..... 96.6.0 + a -o oe em ees ose Piping through ‘special room) 2 ./¢.8 20.026 soak ae een tere eee 5| 51-132 51-30 51-2 ouw21 51-93 51-93 51-97 51-92 51-94 51-93 51-93 51-134 51-109 S151 51-30 51-30 51-30 51=30 51-3 51-4 51-30 51-132 51-109 80-8 51-30 51-121 81-7 31-105 51-102 31-91 51-98 51-91 51-108 51-93 51-109 51-101 51-102 51-104 51-90 51-129 51-107 51-108 51-106 51-97 51-97 51-110. 51-111 51-112 51-112 51-112 51-100 51-109 51-110 51-100 51-94 INDEX SUMMARY Equipment-—Feather Equipment :—(Cont.) Recuimerssiammableiquidss... ssccs0.c.+6.+.>02eeee os ode oss: mecoveryesystems, flammable liquids.................c00ececeeeeees TRGWASE WIRES s o doh Ca ASOT NEI een eer ee Retainers, flammable liquids Existing buildings to comply Exits :— Communications, main exit level....... 51-68 64-15 Communications, SAME OWNER. < 2s. ccu.o56sseee wees nev oec eve cee wees Wierancesmax,, toexit, /4t. generally... .. 26.0.2 eee cee cess cues WoarsmcOMMUnNIGALING ee os. ee de eee ws 51-68 Drygecleaning building:“Direct outside exit... . 1... ccc eee eee es Film rooms: 2 exits, each 3 ft., room width apart Fire area, 2 exits, 25% perimeter apart General, same as Business Units, Chapter 50........... 51-68 Lighting: Buildings 3 stories or over:— NG ditionaleprgies ae secs ye eed ny sea bere Seema ets 66-1 INQ, 5 3 3-4 SGC ORO Ne eae on err aren 9 Se Line of travel: Max. 75 ft. generally PAs a LOMEOPCIIN SS pretest sso eye ob e.2is sees le weed eae a Motion picture trial exhibition room :— Doors to swing out Rooms: Max. dimension 20 ft. or less:— AMexd tarot TEC UITeM!, . 25.12 5.5 2 2 en cons ce cregs ates 8H re Max. dimension over 20 ft.:— PAcMtsweacors tts mins TeEGuITed: «012.2 sess se see mae de en comes SOO omtorslesseliexit 3 ft required)... -.-.4+- 9-205 «see eee OversOUIsquit-. 2 exits; 3 it. required: ... = .c..2ssce042a2-002-2 5: Signs wbulldings:SiStories\Or MOL... .......-...-- 2205-2 s44-- aan teas : ACen eral PON ore ko Ness: Fic tee brio aye Wg aE ae I Wertcalawatn other use prohibited. .............00.000.+0s000 sane enes Explosion Building :— Adjomime buildings permitted... su... ......0-+2-++25- 51-13 IBASeMeMteOOMPPLOMIDItEGs) 12 5.0): 05 ave oo arte nine vise eae Baal chinr eam e lini tions aera gers eres sees odie elt se Seen Ole ie geytysie pee Construction :— Exceptions, as in Chap. 50 Hireprooh or semi-fireproof required.....<........-.0+-++-+-+++<-0-s Defined as hazardous use, manufacturing unit...................... é Wetinediasyhazardousiuse; storage unit. . 2.4.4.2... 56-0 - sees oe te SESES. CELT ae ae ee AR Nee Pos fe Wiohiine electric: Vapor-Prool...>..c- «2 9a eo ye 5 oss ee WiticeNO persons Permitted. aieo~ cis le Ate oar rarer eae eee IR@aiin, GISTMUta Ge Jo emeds Ga eRe map omictnes Bae aaa dee ep - SAIN’ COC GS A Ee aH ele ae eS ie eer cee SC DHAPRVECICAFATICE CXCEPUIODS,, ... soc. sion nee Sqes oe ae ease ps demee oh SUSE. CHATS 2a ote Cue ace ney Par ie ce Oak ein CNSR pean Cito corns SIS TISMORT COR PRA cores renova icis\jsletane Gina isletibescierbevelsderens rote Cyeraesnedeouphans SIzepMaxerastin manUtacturin Pave 3... cess <2 5 stele oe eee ee ne Sprmklers-|Generallysrequiredan cr -- sls cty-)-7- yamanse ieee ene eer DIE BISIOTONS SS DANI ee ne eae es On ARSC Se OE cep etn tye Unlawful to use other building over 2500 cubic feet gas............. Werittlatronprpy ag o:< cic cs acco bene a2 eee nein oe 51-86 Explosives :-— Adjoming buildings permitted. ...................+.. 51-13 PAUEHORIZed nGehnitlOne eae te aa) senate Seer See hc Basement sroOmspronibitedon. se eis, scysya iis eeleustcrsie)? cusps ele een re nae Werredtasihazardous USE. «:. cisiv2:5 sc. - - 0 urs Sum epee ee ae Wetimitionszeneraleys ters cae o> «tales crane eke Oe cree yaa ee parewoerccvuniawiul, defined... «2... cic. « o shjcneencioree wsasiea ae OEIC EMORETSONS PELMILLCG 6 5 ca. ayes lave ols Eafe eitaie vinctuan, serie weeds brilenwier Mele fed a, &) <.cheta G2. ene, ners aren cichehe ia atl erate Sat Feather Renovating :— DetinedtasihazardousiUse cine cere eee ce acre roe ert oremn ns es SS [FEL EEMPLECIMIMLEG 8 «v/s = 15 cores tate etme ale ware edie ot nena have 122 Filling Station—Flammable INDEX SUMMARY Filling Station :— Not garages, 1f cars‘cannot enter... .....5. 202.020 2 pa oe sate ener eee 52-1 Prevent gasoline overflows... ...02. 402-00 e0eens sees soe Oe 51-47 Film rooms, See Nitrocellulose Products Rooms Fire areas unlimited :-— Fireproof construction... ...:i.00.2.02 200. e nes ode ene cee 51-56 Semi-freproof construction... 20.0 2: oc ceee ne 01 sob nee a eee 51-56 See Construction under each hazardous use Fire escape signs. ............--2--020005 66-15 66-16 66-17 Rire- extinguishers... oss cscccc00 ces ss abe eee wns dulse om oe eee 51-127 Fireproof Cabinets :— CAPACI 5. sas eo Seee wt aale die sis silane awl eapata tae © Wane tee ee 51-20 @onstruction...6 c14.< sve. te end aed a8 os Oe Sere Oe re ee te eee 51-20 Sprinklers) 02). c.x-0. 5. selcadwn sow aion adie noe ne hae Geek See ee ele ee 51-124 Storage over 10 gallons, under 50 gallons......................2.-065 51-102 Wemtila tions rc cc occ fic suv teers vd cia'svoneié onepapnee bo sree eviaie «oh wherseseat tle o Reem 51-79 Fireproot construction. 5.4.4. 0% 534 2.0.04 eae: tee oe eens oes eee 51-56 Bireprools Val €S% 00,3 3.0.0) cP ein 4 0 avec Goes + cuceee Oe eee 91=32 51-21 Fire separations. ..............0-0eeeceee 51-67 51-97 63-3e Bares open! Prohibited: 22 5.0%.o26 40014 secu s on. oe ere nee 51-99 51-94 Fireworks :— Basement room prohibited: . .:..0<+5 0422 6¢sssecet dene na'sce 6 ee eee sy Sy / Defined:as hazardous’ use... <. doe. oo eens eee eo eee foe ene ener 51-3 Definition, general...< ..s5.05.805 bawass cs gat os nse Oe ot ek Oe 51-2 Satety clearanc@s. cs... 2% o./s.6gaceiain es «4 pease tee ale an ee ee eee 51-17 Unlawtul.defined:., ...0... 0.06. cs0s0 ds oc eice spaces taale ds (aah ene eels 51-2 Flammable liquids :— Capacity limits............. shone: a ach wo ASROORe eet Spee ake ee coe ee 51-52 Classes :— I= Flashpoint: under 25° BF, ...2.0e0s <6. ades2 eo -eee Suis ae see ae 51-2 It Flashpoint 25° to707 Bs 2.6.4 oA 2s tas eee ene eres 51-2 UT. Flashpoint, 70° to 187° Fs, . .0.0.0. seeese se Hae Hee pee be oe ee 51-2 EV. Flashpoint above 187° Eo, ..i¢200 ah. ee ee ere ee 51-2 Wontainers:2 : sise% 6288 G2 Sosy. 3.0 511520 eee 51-2 51-102 Defined as hazardous unit................-.-002--05- 41-1 51-3 DGMVCTIOS oe 3. he Sb tore stin pda iS natal =e ee ee 51-101 Filling: pipe and hose ss).2s6 cscs !02.c s!.08 sate eed se eee eee cee 51-101 Mire Extin PUISHET: >< [Groic' a cee MP Adee Ree ca RE eee ec eee eee 51-127 INIT CS OPCS, 2. hosa ise te coca aioe he aulat a atayol banaiah AAPL 51-94 51-99 Flashpoint test requirements. :.<..... 04.00 <7) 2sasies eas one sees e eae eee 51-2 Frontage COnSen tSincci2 és at's: sidiars’ att aeeeog a Coie ee oe ee ert ee 59-8 Gasoline GE ViCeS v2.85 ccg.scecers jap oid plastya SR bei eae PURI rere eee 51-104 Gravity feed prohibited co sin o.esscres we ee ee ee Se 51-101 Heating equipment <5: 28.60! ease a roderc ope eo ee oe 51-97 MAI GNtS. OPEN es ads acres wud oleae av enavavle eve tans eae Te ome 51-94 51-99 PUMPS FEQUITE 2% 15.2,< osnsAesains ais 5.2 atlayhatets seh terrae 51-99 51-101 RE ClAIMELS 5 Oho ence e Bove skated enn ick Snags, Ee Oe 51-103 RECOVERY SYSTEMS) «foc. ene e-seesnt cin Gee ceen. ae ee eee oe ee 51-103 ReleE Valvess: ¢.é:cd.6-swiew cnie sears davnd oa oe eeeaniy St eae oe aes eee 51-100 ROOMS 3.2) sye%s ans ccoottes 4 duos f a chiceid a SpSed o-ane als seavesaue rete tty cee eta NOT 51-82 Safety clearance :— ; Condensing plantsic237 <....<.3 23.2.0 4%, Giclee ee HOE SN SE FS Sn ERS OE SE RECLEAEAMCEECXCEDLION = Satine s = eo oe a oe Se 5 ase oN Mee wrest oe melolets SECS, CERCA co SHEDS. EXCL, oo SSC eRe eee Se A re eR L D se Sprmdersreduired:) General... e204 0... 2. ve dawn see aoe ss eo eles “ESS ELECUIGOTT: a ag Oe eee eo ee Gace Unlawful to use other buildings, over 2500 cubic ft. of gas............. Fume Room:— Rae CHE IEOLIICCE! Ieee 5 oa Fo i'n ins aa «SR aINe Toe Oe Ue ate ene ate MAtter PUES COUIDIDENE? "Pays fees co5 pees a te eee eS PURE Kee HOG EA INS Gem Eide ou pmo ae en ates os Gh nod anon onde can adoqne RSE ESTES LESSIG Ste otis = aN vs chaos inn: Wi are Noa SR Re ee BS arene ae lee eis hr enh OR aks os hd wide cgay wa aleiele aetna Asoline pias and Other CeVICES «0.06. noe ke ceed Ree ttn vv ee oe en Gas plants, see Public Utility Gas Plants (Genera laimitad erne dary: orci cua ais ans ernie aueidle sots a ee ae ree Sera 123 51-52 51-127 51-101 51-127 51-52 51-52 51-54 51-54 51-54 51-54 51-54 51-53 51-82 312 51-82 51-82 51-82 66-18 80-8 59-8 51-66 51-26 51-57 31-2 51-26 51-26 51-26 o1=3 514 514 51-132 SU 51-66 51-2 51-13 51-13 51-115 51-133 51-121 51-121 129-70 INDEX SUMMARY 124 | Grain-Illumination Grain Bleachers :— Conveyors, automatic closing.......... 51-91 51-107 Defined as hazardous unit Defined as hazardous unit, Ducts, automatic closing. Fireproof construction. . . Safety clearance........ Sulphur furnace......... Grain elevators :— manufacturing Unit... 2.5 ..05 a) see Conveyors and ducts to bleachers... .. . 51-91 51-129 Defined as hazardous unit Defined as hazardous unit, Definition, general...... storage Unit... 3.64 ace daeeas o0 ee ee Fireproof construction required... 0. << j. 0 204.055 0. uns ase Lighting; electric: Vapor=proots: oie2 8.025.326 sea ee ne eee Safety clearance........ Standpipes required, over 2 Stories. ¢....5..4.0 445 0 sae coos SRE Grinding :— Basement room prohibited Construction, general... . Defined as hazardous unit Defined as hazardous unit, Dust collectors.......... manutacturing UNIt. <..2 20-25. ee eee Lighting, electric, vapor-proof. << 00isqeits onless: 2 hr. construction..............:.-5....5-5- Rogma@OvenU0isdatt.: > hr construction... ....2.....2+-.- 2.5940 6e Magazines, Explosive :— eet eerroemiUE HNUIONIS A Ae eS. cw nis Sake a SA Hine S85 coin EEE iteascsamorenthan: 100%. ois ce ceo. ce eit Bes omer nme osetia Seconduclassplesssthanml O22 4-1... eects cer emraee cee ieee Construction: First class magazine :— Basementeprolibited ay... marc. tras s oe gees erie eo selree ea oe Woorssnon-combustible or metal clad: ..... 0... 2.5.22 4e5: casu-es-- eighesmaxrl story max. 19 ft... 0... nec wines ct erae ees Boom Baez eM LOUIE. es cles. nds a se ok cons ecinsins 6 oceania mionccomlnistible general. oie... ess seg ie ce see eb Heese SHS, CEG Ge ae eS neat PME NS ear SUSTS. GRIGG, See ee a ene mem Ae rer YS Mears cero RUMOGNSEUCUDEEIMIGLEG. >< eae ees sie) 5 oye wr ole ia termes nls wie gs ww Se ge ae Construction: Second class magazine :— iicMearrEe=TELALGING COVERING cs . ... 002 es ieee bots os ssc ebm gape s DIP eCCIACHIAZATOOUSUMIE. << ssjics soicc-a b= Sesriem ayers Meee atte ae Wetmedrasihazardousiumit,storage UMIE 2-222... 1-3 eee Pen RELECETIC LVAPOE-PIOO! = =. asc. 6. seme sate ae, cube wus youn a ws enone Safety clearance :— \Wiitdhy [barri(eng Se eee eee ams aia eS AEN oa cearda ADS ok Wathonmbannicadesmarrc datas siete ite APES Meer ert Unlawful to store explosives in other buildings Malt Houses :-— Wennediasthazardous nites asso eee eee Defined as hazardous unit, storage unit........................... RERINTIGHSNgenerals «6-5 sacec..- cei « = 25. hicks Sew ee alumeapar beara ee Michimps Clectric.: VAPOL-PIOOl.. « +. cick 20s ae ean og wd mei ens Satan? GIST GSE 7 Oe lo a eta eee ea Painter cach fener ake he Seam PIPESHreC Mined: OVET. 2 StOTIES p< 6. 2 ce = oe mm seni es aals 2 Ym sho MeCN POET PMT EVGCHIEM: «fic os. cixa 2 tara's «since no AWe Wu eeietere oases yaya ol ans Retreria senioiHAmMMADICS fire so ew ones wit ve aoe ee neato iberialowinienlyiNAZATUGUS.0.5 9 <2 ea ee vos «+ Mig nosis siti sinle Awitie oie > sch Mieipert als paeTOCENUIOSEn4 5.2 «x aha vealed. os Fo dives Sie Onn emhaen ne as 126 Mills—Nitrocellulose INDEX SUMMARY Mills, Cereal, Food, Grist and Starch:— Adjoining buildings permitted. . . 2... 0000500660 eens sot eee Construction: Over 500 lb. per 24 hours semi-fireproof construction. .... Conveyors, automatic closing.......... 51-107 51-129 Defined as hazardous unit... .....:..0...62552 00 ts das See ee Ducts automatic closing... ........ 5 ce. 66 54s ee eeenes sols es eee Electric lighting, vapor-proof. ... 2... 2.20... 00ss4 av ele os ieee ®iice, 6 persons permitted... 1.2. 6. st. ce ns wan 4 eveu< dese ee Sprinklers required, dust and grinding rooms...................-.... Standpipe required): ..6. 53 a5. c25s0e ses annie aie set ata ee Mills, shoddy, See Shoddy Mills Motion Picture Studios: Defined as hazardous unit...................... Motion Picture Trial Exhibition Rooms:— Defined as hazardous unit... 2.06.0... csqud- ene a ee na so oom Exits :— Avea:600:sq; ft: or less, 1-5 it. exit 25 esos ac. ch eee ss Fal cote eee General . oo gccc eases cectededace a bb 0 oo alt pasislaye aeaielelens SIs cS Floor, same construction as building: ..: ....200.50.i0- 2522s ecm emer Need not comply asitheatres:.... ... 6.0.06. 5 ac haves 2k 4 2 ahaa Projection room :— Inclosure same as in theatre, Section. .53-33 Incombustible supports: <> .<...00 se0e0es onnda sos has oor e eel oeeeee Openings, closure required: «:....13 2.2.7 saeeeer erase 51-38 Room, max. capacity, 50 persons. ': .. bak naa cae cepan stag aie Seats, fixed required ...5 2.dcn-ten 51-66 51-73 Open air assembly unit: Min. clearance 100 ft...........------+ sees eee 51-5 Wpenmure and Wight:devices. .. ... 66. c eee ee eset eta mene cence: 51-94 Paint mixing or spraying room:— eee. Basement: PromIDIted IMs cee cers 2 ae oie eee se ti wm ape ecniemiens © nme ors 51-57 Construction :— ; (Gane Se en ee rene ees bern cc corte 51-30 Heavy Timber or Ordinary Construction :— ‘ Room=600'sq. ft. orless... . 2... ce eat eee ene e cee swaee = tplane 51-30 GOOmGutt: to 1-200 sq it) ge heed inte oe els 51-30 Over 1,200 sq. ft., 4 hr. construction. ........---++++eeeeeeeeee 51-30 DWefinedias hazardouSwMit 0.0206 cnee see es sues Sil om mreb isis 51-3 Defined as hazardous unit, manufacturing unit........-- +--+ ++ sees ees 514 Definitions, general, over 10 gallons, per day......--.-..+++++seeeeees 51-2 128 Paint-Room INDEX SUMMARY Paint mixing or spraying room:—(Cont.) DD) OOLS ios cars Ose e ace Sptehe Sua buara hve d Ddiele Sits SRE RS 7 AE CT Oe 51-30 Guards. 6 i iepova re Sheol Savssapscaen ohn etes ays het REA Ie 51-112 51-106 Heating by steam or hot water only... 0... 06 2.0% ..ceds ue ee 51-112 Lighting; electric; vapor-prool. . 6... acc. 55000 ee ttee io. ao) he eee 51-132 Piping and. ducts' permitted... .: 0... ....02005. 00 s05> Oe Se 51-30 Sprinklers Tequired « 5 ....2 si. .cc4 ¢ tose tele pte tne een eee ane eee 51-121 Ventilation). :. < s<-2-2-0b osc 3 os carers «2 ernd & Gard ow ate Romney de 81-7 Paper Baling or Storage:— Construction :— Fireproof: Semi-fireproof, or heavy timber, 2 hr. enclosure........... 51-46 Ordinary construction: 1 hour enclosure.......................-... 51-46 Defined ‘as hazardous tit 252 42.5.52.02 00.0 om oh ence nuis 2 dives ae ee 51-3 Defined as hazardous unit, storage unit... 2.6.0... cca eestor een 51-4 Doors, G5 MUN. fe oo. seman essa nes faa seein ccd ayn eens.c soa Ae 51-46 Permitted in any building....<. 2.4.5 222.00 - eae co once Hs rs were eee 63-2 Sprinklers TeQuired ; < oaa. nema nea sansa es eke eee oe ee 50-50 51-121 Windows, Type A required). 6.022 cei ce cos es em ba ee oe enc ese eee ee 5146 Paraffin Room:— Basement: prohibited ins ..2:252 ive es.2i antag el aces o etieiee sta ee 51-57 Sprinklers required): iyo «clam reefue <21s ace aes a estat epee ee Oe 51-121 Ventilation... fs a srewia atin be ser eraes cree ner eee oer tee eon eee 51-86 Picker Room :— Basement, prohibited in @...... a >< vecgp es cee aa eetese cannon oeeee eee 51-57 Construction :— General, 2.4 scacenscne hie See 51-42 51-45 51-43 Defned'as hazardous unit: 2260.4. occ oe ec nase eee 51-3 Defined as hazardous unit, manufacturing unit....................... 514 Fire extingwisher o-... .os.cwsawsadidine e's csi geine sues Syne te we needa 51-130 Fire doors required on spouts . 220.0 ce - Gass erace acs Src ogre see ge OE 51-43 GATS) isa< ifs aed Gnas cam Ane eae eee 51-112 51-106 Heating, by steam orhot water only. ic. 6.cccnen poten casas eee oes 51-112 Lighting, electtic, vapor proof.isoic. 54 vaanors aes eee eee eee 51-132 Room size,max. MOOS: tts: cs osc sass aectec ere eect ee ener eee 51-64 OUTS) Tre COOKS: .4d.a.a. de Dulias athats ales se ate emma ceteee wean a eheh a eee 51-43 Steams JOES 6 oo cicr's. chay0/cte torch dneig ne GAS 2 eases PROPOR eee 51-130 Steam’ valversigniom fre line: 3 2-.- eT ee Oe 51-22 Defined ‘as hazardous UNit.., s2.< cco. 44-36 0e 410s, cteine ote BO eee eee 51-3 Room) max.'size, 1200 isq. £tis.....ccee cw s eas cise os Ree Ree eee 51-58 Sprinklers required 5.0.00 -iyere eae bane ce ee ae ee eee 51-121 Lwou(2): hour separation :..:5.. cis ..05. 0350 od pane lager ole ee 51-22 AVICTEHIA ELON. ease ois oe ssisierdies aug va ett oF eon, axel os VEE HO TO eee 51-86 Roomusizes: General |... 22 e's ovals ee ans as eee Pe Ae 51-55 51-58 S| INDEX SUMMARY Safety-Smoke House Safety clearance, definition School: Min. clearance 100 ft Semi-fireproof Construction........... SPEEA Soc gts 6a ae ne 51-67 51-97 Shoddy Mills :— Wetmedjasihazardousiunit. . 2... 2252.0... 50.-200--:- ‘Sjomialkleins mao uindeelS 8 Be ae eee eg ee Shredder Room :— Hascwient eprom bitedany «2 Sa. 6. 02 sac see ls sesso ete cige oss Construction :— GomMneiealll , ge 6 68 eee es ee ee 51-45 Same as in Section 51-42 and 51-45 Defined as hazardous unit, manufacturing unit irerdoorsrequired onispouts..........0.2-+0ss++eee tes as LOTS QIEINEAUUSI NTP 5 ‘quate cutee Get eRe neta ene ae oe er Slee ee a COGS... o onda Uae ee 51-106 Heating by steam or hot water only Requirements same as Picker Room Roompsizemmaxs IOOQ0ISG Tt. oc. 02.005 scans snes ae sche SDOWIS, Hie CONS so o coe oe ee een ee ae ane SED TOS. o oc 0 dad Bee BEG eee eee Steambvalversionion fire line. 2.0... be ee en ee we see est WE EYSOR . ¢ 5.0.6.3.5 6 Oto CE Renee ee ee Ae Signs :— ERTS. soc ocgew oot Eee se LRPRENOnall 52302 A Rgp Ree ere 51-96 66-10 to ETGib: odo oe 050 S00 e ae one ae 51-133 66-5 to MIEHEIMe electriGC, VADOL-PIOOl. . ... 5. oe ne we ese we eee INS CSCNDSS 9 4 a0'd Gace eRe ee 66-15 66-16 leioma Ini Wale, o -366 CaO ee ae Sars re VP URDT TRG CTI OSs Gea eo ee re era Silliss——Aeral Wels. So o,4.45 See ee Utes call OMS PPP Ie Te ee fas as 3) euctius wave Repos Gee ae aaa Hlaninabplemiquidssvaults).., 04.25.5002 gece se cogent on we cecmes Smoke House and Rooms :— Pajominebundings permitted... .........j02 se. cet eleen eet eee Construction :— PAOKcubicwt-comless; 3 hr. inclosure. ......-..s.:e+-+s-ceesnee BOMGEtTOTsESSH Gl ht INMCIOSUTE. ¢.. 6... ces nee enemies oe ee Over 210 cubic ft., standard fire separation required.......... Over 30 sq. ft., standard fire separation required.............. Gombustible;material prohibited... ...........00.50085 eee Woorssandeiramessiromjion steel... 42.4. +. Ja40550s4s2 esses Firepits, 4 hr. construction, except portable type.............. Hireproofior semi-fireproof required. 0... 5.).55- <0: 2.0a-2 +2 Floor construction, standard furnace foundation............... Gane, .5 ce6 5064 pe SER On Ee near eS Sickel man ar Over 210 cubic ft., or over 30 sq. ft. standard fire separation... . Smokenimessexcept portable type. =... <4). se ese eee RS RETIRE TESEC OMe Se seas etna Bet Maaee mate es Jo Seals Thirty (30 sq. ft. or less inclosure 3 hr. construction........... MirolleyZOMeNlIngS!, COVETS > sc. exe oes ene oe es era wig chcin otal oe oe Two hundred ten (210) cubic ft. or less, 3 hr. inclosure........ Pntdomseayne Ay TEQUITe” of side oie «aj chp ieiivie Pratea weleale lDaiimes] ag neve oie bile, wine See ce beuee ee ce reneeuesacrscdacse- Defined as hazardous unit, manufacturing unit................. Weinitiongeneral, meats Or, NSbie. 2. ce. oes a aieleie eee Equipment ‘completely incombustible................+++-.s5--- WiicesOwpersonsmpPermitteds = hee oe sce os wae «ase epevissebelerele alers Portable Smoke room :— eMiICeeMIe tA nen: Oz cle Fe ea vale aaans vit «6-4 Acdnee aia (Clearninces bac ae. eri sete ey 51-49 DipICS aS HEE ETC Lalcnepe ya 4 die ke coud. « eis alec aan gee oe ae BiremitssmetallOn legs; be ce shee s wte vee os beled Winkel nea hie we HOUTIGATIOTIME ME Menten ce ote ode aside tye ake See eel 80-8 130 Smoke House-Vaults _ INDEX SUMMARY Smoke House and Rooms:—(Cont.) Portable Smoke room:—(Cont.) Smoke flues, metal. oo00 0% cee ets os fe gb oom Dyes pe eee 5149 Walls, metal 0.3.2: his caicun te jae athens meets Betton cee eae 51-49 Trolleys, hangers, rails, incombustible. .. ....4 20.4060. 0«e000 0000 51-114 Sprinklers :— Not required :— Chlorine gas water purifying unit... v2.5 625.0. so2. hee as le eee St-121 Explosion hazard F:P..or Semi-F.P. unit... 0.2... «0.05.0. eee 51-121 Fume hazard FP. or Semi-F-P. unit... 2... 223s. ence. 2+ os aoe 51-121 Gas plant for manufactured gas... 2.4.2.5. 2. oa ae 28 hee 51-121 Water purifying plant... os. ceaevece ec cet wa we Hee ate cut eee 51-121 Water refrigerating plant. ...0.. 0. 60... cjce es she codes ome ors = ean OE 51-121 Prohibited :— Hazardous chemical building... ... 0.2.2.2 0. nck ee ew dee eee 91-121 Hazardous'chemical room.) 6¢..<'0 22. ee see Seo 2 ee oe ee 51-121 Water hazardous rooms... 3... tse ccien oat oe te seed ss coe eee 51-121 Required: Fireproof cabinets. 2... 240 cert ee ce shows oe eee 51-124 General) aed sibs Tox atlas AO cote Ona me ee 51-120 91-121 Standard Fireproof Vaults See Vaults, Standard Fireproof Standard furnace foundation... ...0 002s: assis oe tengss soe deae cor et nome 80-8 Standpipes: Generals 2 o)2.¢50.. dacs. obo eelroon de Wee oe ss ee eee S1-122 Required, all buildingsover 80 ft. high... 2. 22..2..60.05...- 2-5 Gome 51-122 Steam: fire lines: <25 22 :ocwvayeg a oe wetanes fe Reena 51-130 51-128 Storage Umit. defined a tied cc.ceceass oA eee aeecy aces oes AE eee ee ae eee 51-4 Straw Goods :— Defined as-hazardous Unit.:5 «a. dee< das ses ee aele ce ee tae Sees a eee 51-3 Sprinklers) required) :3.. esih20.5 swt eee ors eee ic sucre ttle aan kp agers 91-121 Sugar grinding; Defined as hazardous unit..................-..-0.-00000- 51-3 Tanks :— Generale «45. 22.5.0 ...0.5-22 5 see + 1s - : BxceptceAs/allowedunio3—2 Wand! 53-225. . esses Ge eee ee 2 Courts, See Exit Courts n iE — ~ nN 46-1 to 46-6 63-6 53-25 Se) 53-25 53-25 40-1 53-1 53-1 53-59 53-34 53-166 53-27 53-116 53-28 53-28 53-25 53-14 53-15 53-15 53-1 53-1 93-114 53-97 61-84 53-56 53-131 53-131 53-131 53-9 Seal 53-25 53-25 53-25 93-25 53-33 53-87 53-12 53-13 40-1 53-165 53-165 53 144 Curtain—Doors INDEX SUMMARY Curtain (See.also Proscenium Fire:Curtains)). 022%, 3.2 «eo eee 53-135 to 53-160 Curved public stairs... 2.3)... cue oe en va vee cee ose 2a ee 53-101 Cut of steps, 10'in. mins... ..0.. 2. see 50 td cocn Hee cbs oun ee. oe eee 64-31 Except: 9% in., curved public stairs... .c.5.0 hs es be oe ee 53-101 Decorations elsewhere than on stage.......... 6: S220...) 2-. eee 53-172 Defined as: Displaying motion pictures.........5........00-seceseenees 40-14 Presenting theatrical performances... ...2. 02:5 .e8sse0s- as peh eee 40-14 Directional exit signs, See Signs, Exit Distance: 150 ft. max. along line of travel from any seat to public normal exit door in auditorium 2.5 og hee ee eleie oe otncie bo oe balou ene 53-59 Doors :— Auditorium, inside normal exit: Incombustible....................... 53-110 Between dressing rooms, in stage block :— ASmins door required ...¢ crsiee ee eevee eee . 53-50 Locks: Egress release without key ©. ..¢es.i0ce ase ...0.c,#..seh2ccnee ss ons nae eee 53-86 Except: In courts ‘with ceving....uc.s5.assseeeaeeen arene ae teseeeee 53-86 Type A required generally Type A required within 30 ft. above top of highest emergency exit.... 53-86 Exits, Employees:— Court, exit:— May be used as €mersency emit oi. S26. oa.55 4 ease: 53-49 53-90 May be used as normal exit... ..........00..es0aces 5349 53-90 Doors, outside exit: 2 required from stage block Type 2, from opposite sides of stage... 6.4 .%.. ore oc sues eee 53-95 Door to stair may be 2 ft..10 in. im clear, «...¢.0.05..2.0si5 040 oe sabes 53-50 Emergency: Solely for employees use... . 1... 244.005 +¢450s000eheauun 53-49 Exit other than entrance required)... 4: ce seals e ces ce ses og pee eee ee 53-94 Fire escape, chute: Is emergency exit from fly gallery, loft, gridiron, etc... 53-107 Fire escape, sliding: Is emergency exit from fly gallery, loft, gridiron, etc... 53-107 Includes only exit court public emergency exits...............-.--555 53-49 Includes publie normal €xits,. 2.53. dt.w is caste es eee s te eee 53-49 Ladder, permanént:'Ts emersency exits .253 4: 1. 4se0u ds a0Gee ee aoe 53-98 May combine with others. ..3.<2..:csete oa.) -eeeen Lee 53-96 a INDEX SUMMARY Exits, Employees :—(Cont.) Stairs:—(Cont.) Mieygecovesmorertnan | level <2 se oe ee eee eee ee Midthnes basement stalrspopttsy Mile eis sie cess 2 pe sees wecis srs ID RASS iRovoHA, Gare, Tabs Ae boos ode le moe meebo ous Oconee iG Goes enera len en tan T sever Asc m ysl-acvs Mersin elses Since waxes Exits, general :— llevan Oia mins) wadthwbased on capacity. ....ess-e6+-e22+c2.--2-- Miterationsstolcomply inexisting theatres) +... - 4.42 ce. 5.52 - sees Classified: Public normal exits DRT OKSEN Galle J 4 cies eee Oe ED ees oes icete ae Common exits with multiple occupancies prohibited... .... EXCED Ep NITELESCAM OMe teelacs, ace cree es 2 evn earner ciate ick ee (Concealedidoorsspromibited ays. sas > dancer see eee sues Hee Court defined (See also Exit Courts) Cumulative increase in width to outside Doors, see Doors, above Drapenesiconcealing doors prohibited. ...0.:4202-0- 00-00 s 002s sess +> Mere ene vad enn cdmpmres cri ts Mise. A8 fr, ceyomneey gkre cities aera untromials Gates at outside ends of exit courts Height, 7 ft. min. in clear Except: Exit court passage or tunnel, 8 ft. generally and 7 ft. at gates. ecient Md Blas core cacle Seetisiby 53-86 liltumination: Normal. ....-...-...-.:. 53-179 53-181 IDMIS TEANGA y oda catia OO eee ROL ae ier Eee 53 -180 Washi Normal. .....5...0..2.-2..-- 53-179 53-181 to TIMTETE CN CV eee Pp AAAI oer a ro.05 sual clauses: aoe. Pm Savon eerste 53-180 IWS 5 oo u.c 6 otha bidle Rea Ne eee ten ater coe ee MirronsHpnoltlotte demedorsuas aacte sal) eacias eeae es ose eee ease Nioveeneall Gleinaaal,. a’ ara sto arakyo nel eae ee eRe ere ree te ame tiokoes ae = re Opentspace aWadith) TOMt.mine. 03... 2. soa ee oe dee ae Oe Wadthtiasedkonwcapacitya oase-tines cic eiacciadelecec > aac aog-saen ee Other than entrance required from public rooms:— Provided: Room area is over 100 sq. ft.. 53-45 53-92 Groups of adjacent rooms are over 300 sq. ft. total area 53-45 53-92 Public emergency exits, except exit court, not allowed as normal employees exits Required other than entrance from publicrooms 53-45 53-92 Signs, see Signs, Exit Trim: Non-combustible in vertical exits Except: Handrails Width :— 20 in. per 100 persons 3 of required public normal exits to lead to street, etc............. 3 of required public normal exits to lead to public alley, etc 100% public normal exit width to lead to entrance doorways Exits: Public Emergency :— Balconies avertical required trom eachsides. sss .42.-4405- e+ ene. e oe Doorway required at each end of every transverse aisle............. Weadkdinectlyitoverade= acc acces 4 aes COE ia Se nine Combined from opposite sides prohibited. ..2..::....--:-.:---.- Defined, not including normal exits..................... Does not include public normal exits.................. 53-47 Doors :— Hneroachment on public space)prohibited. ...-......6.......--.+-+- Except: Emergency may swing 18 in............. 7 AS) aaving Gor WEG UMC. GaSb sone sod eadooE sso ccues aan Except: Doors asim section’ 93-935 .5..52-...-- Ganemill, Zine, © lbs ao-c.cc- alee Girne cereale Go cS Eire eee ENblicgemercencyaexltsS acc sci is =, aa. on ee nas eieto saeco sea Deimedl, qancall ee ccooomo ca dtrs see ceed Oto bets Delos on meron folie ONL 0 Distance, max. 150 ft., any seat to normal exit door from auditorium. . . eS ET AMEAUTI PMV Ea fos ose Ap sicnsee Bae yevete vieie-e Wutlavere arene coiebaluenchones mec alvin honeles Cunulativemenrease toloutsides 4-4 se eee eee ee one eee 148 Exits INDEX SUMMARY Exits: Public Emergency :—(Cont.) Doors:—(Cont.) Level landings, 4 ft. wide...... biz Set WS.48 dees Paka eee ape 53-82 2 it. longer.than width... ....4..244c esau see. ac Oe ee 53-82 Locking devices prohibited :— Employees doors. ...... oleae Site. Setvb a bg ae he ae 99-113 Public'doorss.. 2.4 <4 rae Os « dels te aces een cesta dee ee 93-113 Except: Principal entrance door... 2... 62. «cscs os sce 39-113 Panic hardware.............. pasan a ms ag aan allen en ve ee 2 53-113 Open from inside without key....................... see ae Baek ISI Panic hardware permitted. ............5.00.0.ceeceeesretsedeseeee 93-113 Exit other than entrance required. ..... 5345 53-92 53-93 Provided: Room area is over 100 §q. ft...\c c0....ch biases. cae 53-93 Group of rooms, over 300 sq. ft..... 53-45 53-92 53-93 See Fire Excapes, below Includes outside doorway at grade................00 ccc cee eeeseneees 53-48 Landing, exit court: In egress direction................0...00 000000. 93-83 Lead in egress direction’. j..¢0. Yoo.) aes nae ee a 2 oe ne ee 53-83 Level landing: 4 ft. wide min......... et eer en iy. 53-82 2 ft. longer than width... 2.65. 2254.2 ssh es eee ean 9 Ae 53-82 Location, general :— 373% at least from each half of each seating level.................. 53-70 Lead directly to prade...: iMoete Bx oakus ae ee na cea aan Lae ee 53-66 Location, main floor: Capacity 600 or less in auditorium :— Distance from proscenium, % seat distance............4..0.00e00008 33/1 Location, main floor: Capacity over 600 in auditorium :— 50 to 663% of width to be distant from proscenium not over } seat dis- BAM CO 5 A7ps Se eis eect ce 2 aac gh eRe nn eee Ae 93-71 Locking devices prohibited... .. 1.2.0.0... 00.0 cues te eeeeeeeee eae 53-112 Except: Panic hardware... . saa ee eer See ee: ee 53-113 Principal entrance Goorsi.. 4... 6o.0.66 34h thc cdanesetmegseuas tote 53-113 Mezzanines: 1 vertical required from each side....................... 53-76 Lead directly to. Srad@s% 4.009.045 00 cade oes sain Balser eee ee 53-68 5 ascending steps allowed......... Serres err rat ree 53-13 Except: Not required, special ¢asé: 2... 240 2<.s aec. lence nde eee 53-70 Inereased size; exit dOor:. ca edi ai's 254. a cays ues eek seek Rae 53-70 Proscenium boxes: 1 verticalirequired=2%.2/...00 0... < od dances seer 53-75 Except: With 2 normal exits........................... Lye 53-75 Ramps: Conform ds stairs( 40.0... dan eGo eos os eee 53-81 Slope, max. 1 in 6........... re oer eae > 53-81 Required from all auditoriums, oo. sass ee oe ween ee 53-65 Serve only 1 side of auditorium... .............00.0000020 00.0 e eee 53-78 Stairways: 2 hr. construction inclosure....................200.e000ee 53-79 45 min. door required... 0.205460. 00 00000 s set cues ebensd Cawenme 53-79 Door same-width as. stair is 4.024 see oe Wats poe ; 53-79 Outside stair below 8 ft. level is obstruction... .................... 63-79 Same width as door served................. fore ; seteles AY. 53-79 Steps ascending outside prohibited 7722). a%:ce0e a ee Ae 53-73 Steps permitted inside on main floor. ee ee ee ea 33-13 Except: 30% of doors not to have steps R- dcal Saeeu eRe EAE ue oT NE ere 53-73 Steps up to 5 allowed in egress direction, inside, above main floor. . ae 53-73 Vertical: Includes:— Fire Escape Stairs oe cigs os 's-c vaeee as he Hes ees eas eee eee 53-48 Interior stair leading to exit at grade..................02.000 000. 53-48 Outside stair from outside exit at grade. Sh eae 5 At gent al 53-48 Ramp, inside, leading to exit at grade... Psat tor epetEone e She tte 53-48 Ramp, outside, leading to exit at grade. . ob: tk te ae a 53-48 Width: 20 in. per 100 persons............ cad wie 53-69 93-17 3 ft. min. in clear. fe ee ee ies 53-69 53-77 Cumule ative increase to exist... 0.2.00 00000 ce ccc oo eee cee eve cece 53-77 373% at least from each half of any seating level. canes See ee 53-70 See also Exit Courts Exit, Employees Exits: Public Normal Horizontal :— Aisles, longitudinal :— Connecting aisles with boxes, 2 ft. 8in. min.....................+6. 53-56 53 INDEX SUMMARY Exits 149 Exits: Public Normal Horizontal:—(Cont.) Aisles, longitudinal:—(Cont.) ID EWIRECL 4 o oe S.ev a -niotd rey CrOng Noe DEERE te ee Ree A RO err nee 40-1 Doorwayawidth=20)in. per 100ipersons.......2-...26.s5-)----2-+-- 53-60 ALi, inating, (yalalilals 8 a geod Cao ee Bienes eee cinco oe AONE 53-60 Illumination: Main floor aisle :— iGitarcandlesrecuire dis. te a. else ducks Ae ea rei didig Hla Hid eso ewe valene 53-181 Except lotionepicture hOuUSeS =.=. = sisaci- eee es oe ea ee 53-184 Specialipertormancess. ein eae sel Eh ee 53-184 Pacandlemeqwineds nc): sss cee se yee sch SO Pie ees 53-184 Lead direct to inside normal exit doorway................ af 53-60 Requiredionralliseatme levels: 22... .% 1.222 a2: ey Ae casey .dd 53-54 Risers prohibited in main floor aisle............ AO oN os. ance 53-58 Slope; max. 1 in 6, main floor aisle.......... Ae ere Se gee ie 53-58 Slope; max. 1 in 6, mezzanine aisle........... Ne hp heteeean ey 64-55 Steps in mezzanine: Full width of aisle........ Pe cpt Bey Lee 53-58 IRV, (Ting anes. GAs Ata Le Wie hairs ae Ye ite ee ee ee ee Ee 53-58 (Citi, iii; itt reece eee rete eee Raines cd are NES BO ae Pee 53-58 Steps prohibited in main floor aisle................ ree: 7 53-58 Wadthi-Seatsion 1 side only, 2)ft.6im.min.......:......... Me: 53-55 SEAS, Om loMN HCE Sites wae ee aoe Goode aoUeesenoedsecs ena: 53-55 20 in. per 100 persons and cumulative towards egress............. 53-55 Aisles, transverse :— Balcony; Lead direct to normal inside exit doorway, or by vomitory. . 53-60 Comeidentalimormal!and!emergency exit: 2.36... os eee ee eee sos 53-57 Deine depen eee ae ptt SIN ovat cdnee tee: atti so lsh e dors SNe Sls 40-1 Doornwayawidths20hn® perl OOhpersonss.-2.----424-- 022-5. ee es 53-60 ALTE, IDGUEMS bate cs cto & NOOR ROE CR RSIS Sa aca i eer a oe 53-60 Hncroachment prohibited: ........2.:-.:-..-22 54: LPhioee oyisenat eae 53-58 arate GT OTIAMN ees here loci cis 1S ajsne eye minh asta steh 53-181 53-184 Reqiimedbinsbacksolslast row, Ol seats. .... 4.58.6 5.6s0e eee eens oe oe 53-56 Except: Direct exit via longitudinal aisle to lobby or foyer......... 53-56 IRESSLSEPLO MAD ILE eran err Meir es cilsctosere a echhn When ania eco octar jeter 53-58 Seats: Number of rows:— Orowsiberweenmront andytransverse side... ..- 4. 622.5. -22--- suse 53-56 Ohowswbetweenstransyerse aisles. 4... «2 -.-Je0 +64 4286-424: = - 53-56 SoS, Waeyin loves IU Oakes yan ao en aeoeom cts ood wee Goede ormeraeieo 53-58 Slopeqapovermnain tloormslomel2 maxes... 2s. eee. oe ae se io 53-57 SLepssOLolibitedtae same meen oils cine ee cart Seatac 53-58 OM DOXESeDalit-w Goll eINITTN Salone occ ey os 5 ne EWES pepe tin ss deg ti caste eles ¢ ; 53-56 Wadthee2 Ohmepers OOjpersonse eee 5° qo secer «oats iit ac 53-57 APB INU PIN CLEAT HY pee Re tel Seed. ra ae aoa eroe ata ns aeons 53-57 Excludes all encroachments...... PS So eee ES ene 53-57 Defined as:— Aisle approach to auditorium...... Bein tage Ne Byer agar xxiv INI pelt Set 53-47 Woonwayapproach! tolauditoniumy | — pp sese see eee eee ae 53-47 Foyer approach to auditorium........ A SS SE ore 53-47 Wobbyzapproach toauditorium™ 6. 4- ote cee sans dese ee =e a 5347 iEassareway approach to auditonlum). 2) >. sees fae ee 2 ses 53-47 Defined as every :— Ramp and enclosed spaces leading to public normal horizontal exit con- IX ACEO Tle, Aries Aca a SORE oat, Oder cht een oe eT eros P 5347 Stairway and enclosed spaces leading to public normal horizontal exit CONMECHON SE ysis ae ei etek oracKae ee ee ontane eter a iiies 53-47 Exits, Public Normal Vertical :— Balconies :— PiveLuicaliexitsiat least requineds 6 + aces remiseiak = +o seriayeisteciesa= 53-62 Bnitrancerdirectatroms balcony Obs. +i utente aerate 53-62 Entrance direct from lobby or foyer at highest level of balcony....... 53-62 Weadstomrorizontalvexitxonimain) tOO%- = =i ive seyeeeen te ieee a 53-62 ocatediat opposite sides) of auditorium. ~. 2.9.2. ssunas. ses 53-62 90° max. horizontal exit connection. ..... A. Gee eee Spratt Ae 53-62 \ Matalin, voavhnt, ai ie, Ons cee ee ate ee eRe de ae cio AeA Oe soe 53-03 JEU ante, taabals (Ces cae oeete oo 6 Eeeromentiad Goer amas. ot 93597 53-50 Mezzanines: Same as Balconies above Obstrictionspro nt Diced seweay ects aici ietekae = ie aie stance isco ofr ee- 53-50 150 _ Exits = INDEX SUMMARY Exits, Public Normal Vertical:—(Cont.) Proscenium boxes :— At least TI required: ..... 6.24.5 ci cna: Geet ones 105 3s ae eee 53-62 Entrance direct from 3 ft. door, aisle, or passage..................- 53-62 LLead:to main floor of auditorium. ...... 2. 626.5035. 56s osc eee 53-62 Stairways with direct balcony or mezzanine entrance :— 1 hr. separation from auditorium. ...5....6..2..9; ..03+ a) eee 53-64 Except: Vomitory may bé opens. <........ 4 casos ostes oo) ate Ree 53-64 Stairways with entrance from balcony, lobby or foyer:— Open in foyer and lobby... . 2. 5 .nde2 ic ensaee sass? ae oe eee 53-64 2 br: separation required in other parts: ... 2 e.c00 sate. seo thee eee 53-64 Stairs with entrance from mezzanine, lobby, or foyer:— Open in foyer‘and lobby... ace0sta5e qncioec a coi alee 53-64 2 hr: separation required in other parts... «2.00 s..90 sees eee 53-64 Width: 20an. per LOO persons... : ... ose ss. s cone so sees esiotie ee 53-63 3 ft. min. general oo yo ces oe ose ee cat setae alee Se eeens tie eee 53-50 4 ft. min. from balconies. 24... 5100. s RNS Sa ae Ae eee 53-116 Size: 40% of least wall area, less:openings ». © .....2.4)....) ise ee ee 53-116 Wire glass, max. 48 in: wide; /20'sq: in. area... 134 ..c0 eee 53-116 Glass:in lobby walls: Same'as,foyers:. . . 2: 4.0.52 2. 6 <6 nnd5. dagen sere de a artati Saree 53-180 Independent:of regulansystem's 5.052 sccnce dss oases Seles See 53-180 Lamp sockets? ic seca cds hab ate aamamie OaRe wisi walee suis Shaan eee 53-180 Minimum: intensities sae ciccvecend oe sos. ag 2 ok wee ys Dine 2 Fe cane eee 53-186 Illumination : Normal :— Comply with: ElectricalCodé. 2..c.5.2.0.cesn es Os 6 baeeee oe a eee 53-179 Continuous use during open times ss .0%4 ce. Soure odes > ee eee 53-179 Exit lighting required :— AISI OS 5 ae. 6 cS wa corsde aden hea edn he Gan fe nes ees ROE Ona eae eS nee ieee 53-179 Alleys): iy: 286.8850, 6,e breaks BR wine Spantate Bat ove Gene) aoe eae eee eae 53-179 All horizontal exits. 2 sca Ss. gu aunt age a «ais hee Mies Meee Oe to 53-179 All vertical @xits ns 5.6 6.8. Ses need Ba deine athe Bede ed obscas Oe ee 53-179 PORTE COULES 2. ie seuss, Saas ee id delve ERIE TR eee 2 EE Ea ee 53-179 Min. intensities :— Additional required :,Normall €xits):.:,.24. aa.veetee ae See eo tere 53-185 Controlled separately o..c:..5:icisls.< 3 ncstaeiuss alas nocn velo ae) NeeceenRor 53-185 Employees @xit: soci cca costs ais sa nscveransie vin sas Marie NOCH eee ROTO eee 53-182 INon-required eXits., 1. ace ien ei tan on aeieie oO ee aee 53-183 Public exits 5.2.5 5820 in lag © cee Se ier Ot Oa eee 53-181 Reductions. allowed)... ..... i445 s,s cone Joacic at Bice oe eee 53-184 See also Chap. 66 Incinerator Separations:.3-..c.c4: 53-143 Mrs peculGris General ryan mech ssusiekecers sie sisc0e eres eed) a,s 13>4 53-159 NDT. 6.5.4.6 6 oes So oman Cock OR NORAD ID ROT EC aCe eer 46-8 Mlgehinenysan dsequipmentee rye ecis 6 seit acicialye Gers oon oe ce i 53-152 to 53-160 Openinestosbe;sprinklered:ispecial case:>---4-. 2-45-22 8-2-4- 7600 -e05- 53-174 Oneramnevequipmentmanducontrolyass cre py cite oe eerie oe en oe 93-152 Operation: Conditions and requirements; .. 22 4-.5----2--2.------2--+- 53-135 IPH 5 ¢'9 6.0.6 0°60 2.5.6 B 6:8 ORO CIEE aI Sty Oct nae 53-135 STO KCN DO CKE Ls meme I Nae A. cles fe cots raters aciene eer edere een eee 53-143 53-144 TER 5 oo hero 6.0l0l6 6 6: OS SRS et ete nn Rahs ec ase 53-160 53-135 TMERANGESS 5 An's 0.6 Oech TE RR On arc ano ate ee eee 53-137 KO) Raid, 1S MBSA GS ae ceaalo Emmis CRN cero icms oes oe ee nee Ene 99=135 sliypessasectionsmetaletype. . ...2s0.+-42.08steee oe se 53-145 53-146 IDG (ADS s 20's odd OBO AI Ce ROTO Oe OC carne ane cee ene 53-147 SINGDWS HYDE.-o 2 ¢ anes SRO LEO eB an eee e 53-150 Wer rCAloperailonenegumined sve. ...s,-/2 0-2 ye « onuae ie Ons oe cise es Stam s eele 93=135 EMplicHasseMpIysUMitIMyEneAttel o..ccls. of occaecin daa cose s eee ects 55-11 Public rooms: Exit other than entrance required 53-45 53-92 53-93 Provided: Room area is over 100 sq. ft.. 53-45 53-92 53-93 Group of rooms, area over 300 sq. ft... 5345 53-92 53-93 Ramps: See Exits, Ramps Reduce ntssprolmpitedtceneralllys 7.05.9... .2.+62 secse seen s ese mse eecnnee 53-178 etriceratingiequipment..5............%- 53-165 53-21 93=22 Neiise@OUnmMeIESePAnatlONS sys. yas ard. stack cis cece nce © aces ceoaicbetereas aon aoe 61-84 Remodehng torcomply invexisting theatre... .......2:--sces eects ase en 534 ERC CPE OMS SPP Tae riciare hensisio. aie. 55 e cicvae ion siaete cist sSidw cat aie aetine soe cue 93-3 Repalissto.complyimiexistime, theatres; >... ...acescans eves severe ctes eae 53-4 [BFCADTOMEs 5.56 Sab CBO bo SOC Oe ie Rn CLO Ieee no ee ae 53-3 IMIS@ OF SIGS: 7G INIT as Gees 6 ABO on ao ee ene eer 64-31 Roof promenades prohibited for theatre patrons...................+-+--- 53-53 OMI sICOMM Ente CMOLISPEClAlWISES® ascetics jonee tes onprcnc nos aneeee ene 53-8 Rooms, public: Exit required other than entrance :-— Provided: Room area is over 100 sq ft.... 53-45 53-92 93-93 Groups of rooms, area over 300 sq. ft.. . 53-45 53-92 93-93 Scenery: Combustible prohibited, Type 1 Stage...................... 53-30 iIMoveablesprohibited wlypenl Stage.) ..- 2+ a0cassenessseare oes moos 53-30 COO lm Glasswepro hi Diteds: Wie wee rte chet cvsi ch oucte'y tors eoclsie eis» sa /eleneuepete a0 63-2 Seats :— Alterations to) comply imexisting theatre... . 2)... scs< seer sec aceees 53-6 AT crOOVen90= between aisles;prohibited.:...a..escss0sesone cusses 53-128 SEMIS equiTed ton all axed Seats. aects a4 + os se ee oriole ne reeen lacie os 53-130 Balcony :— Wefinedkasvoveril OlTOW S's sr-yscdencreicrsenoretch onde sche ousn ci aPe eae eeu de. SS ce seh = Seal 6 rows max. between front and transverse side....................- 53-56 Orowsnnaxspetweem transverseaisles.< - - j.4 aeaade soou ome dopo 53-131 IXY) said ClllON KGS Senet ee A eS MEME Ie od Crete. jee sukeeciie ccc tc bee ees 53-30 Doors :— iImner vestibule door: Non-combustible........-........2-.:+++--«: 593-23 Outside exit doors: 2 required from opposite sides of stage........... 53-95 Outsidelstaze block«door, to be vestibuled.....2..........52.+.2.-4.- 53-23 rojectionsblocksimistage bloke. 226 ee cistene oder 2 ayesha oe cts are 53-23 RrOpeRghysroomMemilestag ev OlOCK encore, «= cepa -vekoneisvors eee, entra aes are 53-23 Storareproommmestagen blocks 3 yer, qs - ciel tteteucnds Iyer Heras ef ac estou 53=23 inlayacleull many lO \OOKG lo en yo oa bememeonG Ooo Caomenan om eon etenmras 53-24 Highest point in Type 1 Stage:— ASiiaemMaxevabove proscenium Opening... 22.5.2 56.650. sseee sees ees 53-30 Sot Max DOVerstage TOOK. «oo cciicccuteide nes cies we winwis wwsoue ols = 53-30 ata etaWallenequined irs: cic tcicc a mck ysscwie s osstaleus ate safes tues beiseccays ae % 53-15 emodelingatorcomply, existing theatres. ...2..2.:.c0-+-+22 222s sense 53-5 DEPALAMONS wily Pemiotavens: ME\CONSt..- . 4 cece ee es eee ee ee ee 95-19 Sy Mee ES tay ew sTCOMSt=m ac attrac Go Sicha oss eS ievennss ee niet emevenneueeiee 53-15 Bxcepeeinemultiplevoccupanciess se ya> qari a es oases kee oe 53=15 Panayocte welll meouninacl’ Gn 5 ok au cacice one oom Googe ieee manera 53-15 Bprimidercmeduired. ype 2 Stage: < os.42 cou coe tee ete alee sean ees 53-174 Bxcepteperonibited heneath stage vent... 2-5-2 o6. +c 2 ee eee 53-174 Mrapidoorsmmavsber.s ie SOldtwoods.5.2-.2-- 2060 ose 2 sie aoa eae Seil7/ Mrapispace-sWened asispace under floor. .2...--.225....-2:25520- 200: 93-1 Woca tl Omplinnits regs cake cesyace eect oie aie ere 2 vers ove Meee oeevapevats uate vavers en 53-32 GO siniiin, loge neapphhrXele Hann uaene ono GomoeDea bos oor eods See oe 53-23 Width, Type 1 Stage :— Equa letonwidthrot proscenium! opening....-..2../--0---.e24+ «ee ae: 53-30 Windowsmotepermitted Mype.2, Stage. .......-2 <2 sent aes eee ne eee 53—11'5 Workshop :— Bimishvand fixtures; non-combustible. 02-2 j.--2e+--4-5-2 4205502 © ne 53-24 Shoploperatedtorstage purposes-e. 4. 2- - asics. ore eee ane oa Seal 22 lois, SFDVMEM HONS CUI A wes Gowode uomanbe bode bona san amemeuooeac 53-19 Stage, general :-— IDYSGHEEL AS. oc och AREER DICER CC OR ACIT CRE R A RCIACS Cl RO Rec occ eer ee 40-1 TOP ehiyghOOM (52) -paccc 2) cays) ayers os 2 oes 53-19 53-1 53-174 SORTS Toons oes ea clemeao ene acme 53-19 53-1 53-174 WWOKKSHOPM ae. cc. 2c - = +c 53-1 53-19 53-24 53-174 Stage, Type 1:— We thMenaaep orl tat wie tusne cldsteh aaa kro Ae inhuciso.s eRe eaenia aitene i aeher ans 53-30 [Dejan mange, Oatins IRAOEG ies MING G np doco boc bbU ag anooe so osUrE Oo ObE 53-30 Poors, weoal iimsn HUN Ssl secpopwoucueudcgdes occubvgcocudcoeude soc 53-16 OMB E HES) PLObIDItedan. «ac. on sia wacis Gee aes cme aia. aimee Bela a neon 53-30 Highest point: 4 ft. above proscenium opening.....................-. 53-30 RB OMEMIN Axara DOVE Stave TOOKsacres cis eee: siete ties tein eee eects Sale 53-30 Proscenium fire curtain not required.................. 53-133 53-30 Scenchyal combustible: sProbibited. 2. ee eases ide perts ere taper 53-30 Moveablesprohibited s Yencva..cc: cbure ae suis seers hits olatts earners 53-30 Sioa, \niwalt eral. Sota rea Beek Gases dick in OMENS cur o Dania orcs Om eRe ors om oc 53-29 DLAPERVCltAregUIned spar. at ccreiche Fv 6 eto ni bos seks iegeneter ee 53-30 53-118 Barre OOLS PLOMUOILEM cy. a5 coisa Sysna ss eel ore Sumiehaunie ec TSE Cea ae ee 53-30 Wsedkforsound projectiononlyseajsc-- +2 sae eee ee eee 53-30 Wentilationssmechanical, not required...) . 4. .2 semester 53-117 Wentsreqtiineda(seeystagebvents) i -..< 5 ece sare hee 54-11 Outside fire limits: Over 2,500 to 5,000 capacity.................... 54-11 Not:more than { story Bighw>..0. osc.samee sha nets sapaacnme see 54-11 Notanore thant tier of seats:high.. vs0.cce.cc ne eee ee eee 54-11 Omit enclosing walls, location 20 ft. from any lot line, provided heavy timber construction is under seating floor..................... 54-11 Wood frame construction permitted :— DOspersonsOrless...c cas cas ce ee eee ee eee 54-13 Outside fire limits: under 2,500 capacity.............0 000 e eee eeees 54-12 Located 60 ft. from any line or building......................000-- 54-7 Curtain, stage, see Fire curtain Cut: LO Fim mins, <. sn sasn geen. e eee eee eee eee eee oer 54-50 Definition of Open Air Assembly Unit............................055 40-15 Drinking fountains required :— Lane of travel Max. 400 Sisco: aso aba ne ea tea oe Guna aneve ener 54-68 One for each: 2,000 spectators $22.) se oe eee bee tee ee 54-68 Prohibited in: toilet rooms... 22 5s,.agie e024 pat betes ko eee ee 54-68 Electric wiring and equipment.......... 53-166 61-78 61-79 to 61-83 Emergency exits: Amusement park devices. ............020.000eeeeeeeee 54-39 Employees exits, see Exits Exits :— Clubhouse: Permitted into any open space.............-.-0ceseeeee 54-36 Doors :-— 2 required to public street.or alley. c54 2005.05 s00s ge teereeen ere 54-55 Gates, sliding: Permitted! <256..6 oan sauce ac scene ee 54-45 Location: Lead to street, alley, or to 10 ft. open space. . . 54-56 55-53 Number: Same as for grandstands..,.....3..0..0-0n2.2ssseetee ee 54-37 Openvoutwards>.... Wet. eee sap dt ate Chet Re eee 54-45 Employees :-— 1 required, for éach room occupied . .3..:2 dc4.44..4.oca.de cee eee 54-57 2 required, for each room occupied, adjacent to stage............... 54-57 54 INDEX SUMMARY Exits Exits:—(Cont.) Employees:—(Cont.) , 2 required, adjacent to combustible scenery....... 300 ft., max. distance to exit, except towers....... IBASCIIeTIt SMC TMM sarees «ous wisi Aswehe cei ou ageteiein soles a5 ; DD cess cerOOM POE tesco tener ey Aes lens Gee as 8 Genenall, 2h, @iling Wate logue cee coca does tees boom eee nore SpiralestainssiromertIGin@Ms se ei eee fees ac 54-58 Windingystainsstromeeridiron!. 2. . 25. .-ce. see aa: 54-58 Grandstands, special additional requirements :— Aisles, Heavy Timber or better construction :— SUlseatsninenowsbebweemalslesas. 4-00. seem ce sess 2s eee 15 seats in row between aisle and rail or wall.................... Aisles, Ordinary or wood frame construction :— DOIScAtssNELOWwsDEtWEeell aISIES sae niie saa sicts cei nee cr .sqcies aes 10 seats in row between aisle and rail or wall.................... Aisles, 24 rows between transverse aisles................-----+-05- Aisles, width: See below, Width of aisles Doors :-— 1eO0OlormMessicapacity= 2 doors required... 2...06.0.4-- 225: -0-5 1eOOItor4 OOO capacity73 doors.required....2..2.c2-2¢:---.4-->- AOOItos OO0Kcapacity: 4 doors required —. 2. ..-.--..--2::.--6+4% 1 additional door for each 4,000 or fraction...............:...... Turnstiles do not count as exits.............. RISeOnbanksiolseatse2 tits MAKy..025 oes cn. - Seat spacing: See Seats Da seats in row between transverse‘aisles........./:......:...02s0- Width of aisles :— Slifes Tabliny CMAN. ois} Bcacke Ero aa bol eee aia Io Sear eRCCT 54-36 (mine perl OOrcapacity.sseats) with backs... ae 4560-4. 222 56ee oa. 6 in. per 100 capacity, seats without backs...... 2 ft. 6 in. min., leading to box seats.......... Zits Oun-=imin...aisle on lyside only. ..- .. «=: - Hangar, into any open space permitted............ Inside? lead direct tovouter exits. ......0...5.-.+4- Obstructions other than 4 in. handrails prohibited... . Paddock, into any open space permitted............ Projection booth in isolated tower, ladder permitted. . . Public rooms, additional non-return exit.............. Ramps Heightiof fight, 10 ft. max, ........0:....:.-: Same provisions, generally, as stairs................. Slopesionizontalvexits els siaespeleliter see seer see asc tc ase er Separate buildings, as per own occupancy requirements............... Signs, see Signs Stairs :— Cure O Sane NA, ees Aa ae ee Oe sd Si NIE Employees :— lErequinedstoreach room: occupledmeaaee eee secs ake oe ane oe PeLequired adjwacent to stage wisy De lle pers ioee yet als aes ais ee Zxequired, adjacent-to combustible scenery.:-.......:....:5-..- 300 ft. max. distance to outside exit, except towers............... RESEINENE Salty Sait aMis, somaoncodcooeedsakoggeL poh bonssancone Dressing roomier nit sn ney sey ee eee Cn Pe wa eee Se Spiral eiromyeridirone 2) so ses nae Hae a eee 54-58 Wadthe! General 2attsiOnint: 2 os tec seat eae ene eee eae Wandin esiromieridiron es eee cis ee eee 54-58 lelhiglatigs Ie Kevtedoti. Wil aite Gate WPS. 5 pce ou ac Sd aachcocsdudeboencopcos IBOttomentoslea datawardsexit.. ee +) --c Aerie ee een ee eee Inline Ou libpAmycs I ites Wales TMD ey ado ole oay an bdudooneeoogdoo- Inclosaresrequine dinar yet oe hace aay Ae ear Se Number-eamusementspankidevices. s- o == semis ckace soe e eee: Generals hays etd hoe eS en ae eae OE re ee sOWeTSaMIISeMm ent parkas sai a6. aerraeut yell ele 54-54 [RUGS Chilly Tb e.g Goo ote sO Pee eae OMmMOMtin UU “100 ISI SI SI I I eal | mm urn Onn I oo tete 166 Exits-Grandstands INDEX SUMMARY Exits:—(Cont.) Stairs:—(Cont.) Risers: At least 3 required... ...::..24.02%% 9ac.cmee te ce COR 54-52 Except in aisles... ..)..2.0 2.4 4 010 ge5 4 ode gfe bee oe 54-52 Separated by distance between longitudinal aisles.................. 5449 Sharp internal wall angles eliminated... ..............5+2.¢eeeeee 64-39 Spiral: Employees gridiron stairs.................-. 54-58 53-98 Steps: Atleast 3irequired. «0. 2.022026 bc Jee tas Hones a ee 54-52 Except in. aisles... i.2. Sikes nda. soe ot oe nee veree Gene oe eee 54-52 Types: See Stairs, General Index Width :— Amusement park devices, 4 ft. min... 22.22.0206 0s does oe See 54-54 Balcony: 250 or less capacity, 3.ft. min... .<....4 .(General..:... .- 54-8 54-17 54-31 54-32 Overt O00 schataprohibitedaern ss acsaeee ue aes ata. ee eee 54-31 Wind eraleOOOMSc sitesi. trie 3 cvs A snickers east y ne oe cakes or Steer dentate , 54-31 DAREMSE DATA OMG h 2) 5s, nc nok ene coke ee eT Sate ee eet ie homeeees 54-32 Institution algouildine: 40hrs separation= sce ecoecoe sso osteo 63-31 Miultiplerdwelline4 ihr separationeeys - cisco esee oa eect eee 63-31 Renmibtedseenerallliy; ae, os erns ocestetey Weic ise ieee ool oe ecient ert Paes = 54-31 ubliGassemblyaunit. 2) hry separation = ops eeeitahreie ee seein) es 63-31 SCHOO @Ashire Separations . setae Supe care ae hols qe eca Sie oe Keener ters 63-31 NepaLationswtire Generali... a.\c skys as te Sicen ian es Cause ers oda ees Seti 63-31 Sinclevdwellings 4 ihr separationias...4.s-scscceser soe asses see es = ere 63-31 ‘INNER IRS. Maine Be OF eNO) Uo RS er ceo O Tanned mente co oer Seta Sa raes 63-31 Open air assembly unit defined: } perimeter open...... 40-15 54-1 Open spaces, see Frontage on open spaces Barking spacess. s7.-- =: - 54-8 54-17 54-31 54-32 Plan approval required by Fire Prevention Department.................. 12-24 Platforms, isolated: Combustible :— Giitqaboversrade- meric cre tats shouts Hee Ses bn nena Nore EPO omc se 54-23 OTOO ORS crafter astern oc cie oe Oy ates chu ieee MOmareis, ete eget newt eatin ee © 54-23 54 168 Platforms-Stages . INDEX SUMMARY Platforms, isolated: Combustible:—(Cont.) Capacity factor 18'6%.. coca. eecc tne wise so ely ee ate nce) eee eee 62-3 Curtain, combustible? 2 4. .c00..0.0. 20s vee Ja de ae ae ee 54-66 Projection booths:— 1 hr>construction inclosure. required. . 20... 0.046005 oes aes Se 54-15 Exit from booth in tower: Enclosed ladder permitted. ................ 54-60 BAKO aise fee acs saetie ofegeteie 3.8 60 erie GoM OS Cee RT eae 54-15 Portable:permitted. . 2... 92. c neces = nae dames Scien ee ee 54-15 Theatre provisions govern generally... 2.2... 0.008000 uence beer 54-15 Ventilation] “se-22 a. see ome ee Lee ee 81-7 Note 4 81-7 Proscenium curtain, see Fire Curtain P aot d 1rePe cA A P k D y rotective devices, see Amusement Par evices Protective floor guards:— Openings over 4 sq. in. to have mesh guard underneath............... 54-20 Protective railings :— Adjoining water or any 3 ft. vertical offset :— Railing 3 ft. high: Max. opening in 1 direction, 103 in............... 54-19 Locations 2 ft. up and also over public space :— Balcony: Solid 4 in, curb: solid 3 ft. 6.1m. rail... 2.4). ...0.0s05. 2a 54-19 Floor-level: Solid 4 in. curb: solid 3 ft. 6 in. rail........0.00.00..0.... 54-19 Ramp: Solid 4 in. curb: solid 3 ft: 6in. rail.....< 0540025 Reo: ae Roe 54-19 Stair: Solid 4 in. curb: solid 3 ft. 6 im. rail... 2. .éeda04 5002s eee 54-19 Upper deck: Solid 4 in. curb: solid’3 ft. 61m: rail... 4.2). vt. wes 54-19 Public assembly unit as multiple occupancy.............. Sos 54-2 Railings, protective :— Levels 2: ft. up, and over publi¢..- SPiiesmMiN MO VemOrMUn GeGana. yes cheas 2s eA cmmint Soe Sec dene acne (Choseiiae iit. Taahlial es Sey cei ne corer Echo Sree Ge eB ert eee cee en Cre Poin t amnemera IDS. Sob ode Rees OOOO ete oOo a ee ee ee ID/g CiyoreaVeMle OVO IN, 7/ Tiles Table & Gb alo ne oe oe Boe n Gama oms aOone poor nn oe ae Ganeraill, 10 ite, travis Sais ain thee b eeoeer tcl Cael ae aries eg ee Gymnasium with seating :— 2 IRE, TEI, 5 6G pie o eed Oat uicie 6 oy aE, OO oo Oe rake eee S ft. need not be'exceeded over or under balcony................... SHIN OVEDOL UNderibalconyarn.sce-ae 5s 4oe oes oss os sae ss ose Measurement :— Wevelsioortolowest pomtiolcelling.. ose sec ces snes oe he sae Highest point of sloping floor to lowest point of ceiling.............. Overmomunder balcony. 8 ft-mins generally. ..2..25..5...6.020-56---- Rrojections permitted! 12 um. bellows. =... 5..-.-..:5:. 55-15 Roomsawith seating arrangements) = ..5.4.25 00.6540. 4004 sees eee yee Se Ce CaO OTIS h/t LSVIMLETNG, seed ee ge oo cas aids Vode, SAR eee os, ks eR ks SLOLAPeeOOMIS s/h Me MIT saya ey es Aci. eee NR tte tints a mes oe haor Tele: POOMNSS S)Lesnilbihats om. coe paw ae Msiahe co Occ 1 1 Gee Oe ae ae Circus buildings :— CapacityzlactorOyassembly;space saa-aeacee eee asec ees deca Capacitysactor 0 exhibitionispaces. 14> anaes stele. le cesses IDesiiaeal , 3 o.o Sie ae OC oe Ca tal MS Ir ini ae ee For tents, see Chap. 54, Index Summary Closets for storage, under stairs, prohibited in non-fireproof buildings. ..... Construction :-— Annexes, 1 story or 1 story and basement :— Unprotected roof steel and columns, if :— IEE SOOlcapacity, onlesse yn ann eel eee 55-13 Zeerincipalsteel. 20nts Up ee aaecem one ae ace 55-13 Se sn ey OOGsroolmshea thing yer ser er eerie yo) Seals) 4, 3 hr. separation, and 60 min. doors............. 55-13 5. Assembly rooms, gymnasiums, natatoriums, etc... 55-13 Basements and floor over: 3 hr. construction :— iPplaassemblyghallsimotoverslestonyeecaaeeeee a-mcekiee aioe ieee Joe Aad Ofover? VENI MYON Or ions. so oeancanacdenouessoccononenae Capacity: 11 to 100; meet school requirements. .....................- Except in:— 1. Church 2. Institutional building St Tae CAeare Teas be aAnnnn nan | os mnurw nun 176 Construction—Exits INDEX SUMMARY Construction :—(Cont.) Capacity: 11 to 100, meet school requirements :—(Cont.) Except in:—(Cont.) 3. Open air assembly unit 4. School 5. Theatre which shall conform to occupancy typeS................20.0.000. 55-11 Fireproof construction required :— 1.:Over 4 stories high, Or sees 6.56. .cec sees ss eee sheds ate 55-7 2 Over 50 ft. highs ‘Or 0. cucteine su bee san te oe Shee 55-7 3. Over 1,800 capacity... 2 20..ocagieec Ucnbhcwe ened tole a ee 55-7 Except, omit fireproofing roof steel when :— 1. Roof steel is 20 ft. up, and there.is; ....:.... ss. iss. sae) pee 55-7 2: 1 hr. const. for roof slabs, ete: .<.<....35.0 avs os eee 55-7 Semi-Fireproof Construction required :— 1.'Over 2 stories high, and. 7... 6g. de os oes + 2 oe toe 55-8 2. Not over 50 ft. high, or...................4.. nkned So ee 55-8 $201 to 1,800'capacity Jay sans vide ose eee ree ne es 55-8 Heavy Timber or Ordinary Construction required :— 1. Not:over 2-stories highs. a fem. d.cccles sod ae cass tee eee 5 55-9 Z.HINOt over 800 Capacity ..c% casa. chins ncn cade vases ee eee te 55-9 Ordinary Construction required :— LOspersons'Or lessi ie c.0. 3.) Sivd-ca tae Se maeee see ee eek oie eee a eee 55-10 Also see Heavy Timber and Ordinary Construction Separations :-— Annexes: 1 story and basement: 3 hr. const.......... 95=13 61-51 Assembly halls:— Ordinary constructed buildings :— Ceiling under: Wood studs, metal lath and plaster.............. 55-14 Floors: Metal lath and plaster under.............. EES, * 55-14 Wood studs with metal lath and plaster......... ae 55-14 See also Basements, above Assembly rooms:— 3 hr. const. over basement in 1 story building........ Sapte 55-12 2 hr. const. from other assembly rooms................... Re mtm 63-6 2, hr. const..from other occupancies. <2 .:.5..c¢<. o.az ced seaveans aoe 63-6 Heavy Timber constructed buildings :— 1 hr/construction for partitions. 45: oes. 42-40. se ee ene ee 55-14 Boiler ro@tS ic ciccsanees otis AA a ee 2 ON ee ee ee 61-84 General 55-12 55-14 95-25 61-84 63-3] Heater T00MS'. se.cc ents fe ae oe ee 61-84 AMCINELA LOLS ios, 2o.cee ce. ateudes haynes tone Oe ee a ee ne 61-84 Reftises bUMMeLS 5. acy ates erence chron te ee ae oe eee 61-84 Cooling and refriveration: Jl. «3.80 cate con caceean naveee ae eae cere 55-89 Courts: Light and ventilation. ...............0hecseeeees 55-6 50-2 to 50-4 Dance hall:— Capacity factor 10). «4.9: sdeceaeneein ae eee sees eee oa oe eee 62-3 Defies. ciscacshtis n'a Oye:dia n.d conde ee gee eee eres oe eee 55-3 Dehnition of Public Assembly Unit pics... ac hs een Cee eee 40-16 Debnitions of terms used 7.5 OR ci vs ees Oe vse drtarn Pepe hens eee 59-3 Doors, See Exits, Horizontal Drinking Fountains:— Assembly rooms, 1 required . 2... i. sh dors dele ee tees eee eee 55-88 Line of travel, max? 150'ft. osc, ebes os a cee eee nearer: 55-88 Prohibited:in toilet rooms..2., Ssein acs bosins oes eee re re eee 55-88 Eating place:— Capacity factor:1O: vaiis..ctasn daca ohh Wa sed Cee ee Pee eee 62-3 Detned.s.99.¢ sky ah oonen ae hae oan Gena eee ee Ee ene 9059 Electric work: Separate from other occupancies........... 63-5 55-26 Emergency Exits, see Exits, andi oso 2.4. .aiccsias nen toe eee eee ee 55-54 Exhibition place defined). 2.3.0. oa cot... 6 sacceee see ee ee 55-3 Exit lighting: See Lighting, Exit, General Index Exits: Defined generally :— Emergency, includes doors, horizontal and vertical exits............... 55-30 sis) INDEX SUMMARY Exits Exits: Defined generally :—(Cont.) Employees :— Includes doors, horizontal and vertical exits....................... Loud Seales; ETH DIE Gece Ae esa eee islonizomiall, alentngel, 5 ecto ba cto ood Solo old Oe Soo oe ciee ra toe cate eae Normal: Includes doors, horizontal and vertical exits................. WoesmotincludeemervencysexitSsa ey qe eee ei = <= See Exits, General Index Exits, horizontal :— Emergency :— Aisles, transverse: Count as normal and emergency exits in:— Al COMIES mall ewer et ies ae ce hae cieterctans RISE ero Gina ee ant Reamotstadiumitype auditoriums, 2.2.2.2 scsc+e o-2 ese 2s - eee Widths Comermdentalynot cumulative. .....-2.0.2+0-<--s--.--= Defined and includes :— IS EMNOLSehVAN PLASMIN PTESS. «45-4 ccisenee ase ease. ome ne Cornidors»notserving, as ingress; ..-4-se-04- esse seen ss ces. DOOKSMMO SERVANT AS HINCTESS. ne aesine oom eee ei a eee oF Hovetsnomsenvin gas INGTESS cela yore soe oe eo we ea = Kobbypenotisenving aSiNeTeSS\..4 .. 44 -4en0s see oe dees ace eo Outside, non-combustible platform (no ingress)............ IbassavesmnotsenvingsaSMNenress. <2 ...2ita- 6. secme- cease sede. Distance from stage or platform :— Max. 3 distance between 1st and last rows of seats............... Doors :— Contonm"tonwallkconstructionn rata oe eis as eae eee ne sie ae as eee Hardware wlocks spantc PALS sy.1.15 5105 fee eps cs ee tes Gisle- aieyn ste May project into 7 ft. clear passage, swing 180°.................. Opentinidirectionof travelus 5... s.-see-6--662- 55= OPCMROUEME ER et hice ance as onto ery ase, 4 ans plats: 55 Outside exit :-— 1 at least required leading to alley or street, or 10 ft. space leading to ALY OP REA s Sic 6 Ga ooh oe women > aco NOU SOA ea onan ; If 1 only: Location other side from entrance.............5 If 2: Perimeter separation, 20% of perimeter................... If over 2:9 Perimeter separation, 15% of perimeter......... Level landing, 4 ft. from ramp to 1 ft. outside jambs....... ae INK? NE COG Seopa tas Dos aOOD ROCCE A ad toca. cin eeae Pre Shallimotienctroachvonistreets etc). «seen eine ote ae es WAG IUaS Batew TaN | eyo eidig Areca ote mine CoO OM Som rece : Onna per. | OO personsionwlshMoormm 5-4 44s eee oe oe 1iimsper 100 persons, other levels. ..,..........-....s.--- Hardware alocks..pamnicybarsselChoe > cm shisrcitine a) okie cers o- cinders Landing, level: 4 ft. from slope to 1 ft. outside jambs............... Level landing: 4 ft. from slope to 1 ft. outside jambs..... Locks: To open easy from inside, no key.............. Open space width not less than exit width..................... iRampsitojcontorm same-as» Normaliexitss.+.5.5-5-+..-.--.s+.-- Required: Every room or level over 250 capacity................ Stage, distance from: } distance, Ist to last seat................ Steps, same as in Normal Horizontal Exits..................... ireugh public rooms, without retum:. . +2226 sacssese cess =k: Width :— DinsperLOOicapacity,on Istifloors..-- sees 4. - 3: 11 in. per 100 capacity on other floors.............. ConidorsminsAiitan.. semen See ere eee ce eee Cumulative increase to outer exit Greatest floor capacity, plus assembly rooms................ fe 1D Yoyogi, Gaabbals 365.07 ds Ay hee eee ais Bicsn bonnie ec pe nes onto Normal] :— Aisle: Longitudinal defined as horizontal exit....................-. ING@ lhioar{ Es rs Mommies ome » cee Seomun oncmon comers oaths Transverse aisle in balcony is both normal and emergency exit..... Assembly rooms: Special requirements :— See Assembly rooms, exits, above IBASECKOMACADACIEV Ayaan Sara eres eater ete ee 55-4 62-2 nn on of on Wor nnn 178 __ Exits a INDEX SUMMARY Exits, horizontal:—(Cont.) Normal:—(Cont.) Defined as aisles, corridors, doors, foyer, lobby, passages, etc......... 55-41 Doors :— Locks on outside exits to open from inside without key............ 55-79 May project into 7 ft. passage. ..0.....5 5.0.42 as 5ceen eee 55-45 May swing 180°. ..5...40000 000% as poe saee chink ons as elle See 55-45 Number: see Doors, outside exit Open in direction of travel. .... «2026. 0002.0tees wecen) eee 55-45 Open outwards es 6 ic 2c fse.e crctsisne were Heels srennee rete ie oye 55-45 Outside exit :-— Must lead to alley, or street, or 10 ft. open space leading to alley or SELEEE . 6 doe Soares oeue Severn cue bier = averse entree Ride ce be ae ee eee 55-53 Number required :-— 2 required: 800 or less.capacity..... . ..cej0eFsreo wes SCs ee 55-53 3'reqtured: 801 to 2,000 capacity® .... 2.5. sscins seanca eee 99=03 4 required: 2,001 to 5,000 capacity. a 4.4 d2:cc sss can oe ee 55-53 Over 5,000, Add 1 for each 2,000 or fraction.........5...22... 55-53 Shall not encroach’on alley, et¢...0<2< 2.0 deecseeess de ennee eee 95-77 Shall not project into passage less than 7 ft. in clear.............. 55-45 Widths:3) ft: mine. eres ae eee ces eemiee ea eee 25-35 Lead to inside exit door at each end, or............0 0.0 eee e eee 55-44 Lead ‘to outside exit door’... 3... 0... ole cece ove ven eect nee 55-44 Lead to transverse aisle at front near stage, in case of longitudinal aisle. . 55-44 Locks, outside exit doors, open without key on inside............... 55-79 Number, see Doors, Outside Exit Ramps, in aisles, slope; max.;1 in 5... .. .. ce cease oes sods coker 55-43 Ramps, elsewhere, max. slope 1 in 6... ..0...e00006esso8 ss cpuen eee 55-43 Steps: If any, at least 3 required, except in aisles. ..... 2... .0000ds8me 55-51 Cut, max: TOM): «ste ad doh aioece Sienna snare tao cree enor 55-50 Extend full width of aisle; passage, etc...:..2 20) .2.62 devs osemseee 55-42 IRISES MARY 1 Wis ate. b ccs cide mean Slama nce erento ae Ce ee 55-50 Separation, full exit width from door, etc................:..05245. 55-42 Through public rooms without return...............00eee eee eee ees 55-27 Exceptions: Boxes under 20:seats 2) 2) wes. casio a ahs ac ronnie aye 55-27 Rooms under 1,000)'sq. tities icx.cee pn eos ne Nee 55-27 Width: 18 in. per.100 on Ist floor: i054 252. seta cchdae cemareene 55-34 221m: per 100; other levels\.a. 7 oc. dgacreavesnred Ao> cbc wean 55-34 Corridors and passages, 4ft. min...............00cceecrececeees 55-35 Except: Balconies 250 capacity 3 its min... «2625 opsceuses eee Od) Cumulative in¢rease fo exit. s5¢4.0.44 sede ied sad gn nae ata eee 55-34 Doors! 3 ft. Wit... 0, es cates aie ae eas eee ce ee 55-35 Figured on greatest floor capacity, plus assembly rooms........... 55-34 Exits, Stairs :— Handrails sia 2sadvesnaete a gates Meee eee eee eee 64-34 Inclosure required, except ist storysi< i .ccacaind saad dancer Sone Oe 64-28 Sharp interior wall angles eliminated...............0..000c eee eeeeeee 64-39 See Exits, Emergency, vertical and Emergency, horizontal Winders, Sin. wide, 1 ft; Gut). .cc.ccsSeaute se cme. scce eee 64-36 Exits, Vertical :— Emergency :— Assembly rooms: See Assembly rooms Balcony :— See Assembly room exits Distance between 2 most remote exits...../3,..c0: 20. 4.4002 Bea Ser 55-68 Not over 70% of width on 1 side of room...................0--- 55-68 Required emergency when over 250 capacity.................000- 55-54 Width, over 250 capacity 4 ft) mim. . 22..:,.0.i Set ss ee ee 55-35 Width, 250 capacity or lesss3 £¢. tims. << ausacd eso as ere SEE 55-35 Capacity factors: General’, « . 5 cigis cle nc een ae CRIN Cera cr aera 62-3 IDEIIMNEGL , oo 6 b.o5:0 aia BIS CCRT IOn ote ROO cee ee Oise oo Chere Rome ae ncn 55-3 Lighting :— IBSO1T 6 oo a o0.0-c)cte HORROR IOS ee ce 66-1 66-2 66-3 (Cencraleper eee ce icccccacichanteces 66-1 66-2 66-3 IN(@TAMNE| 5 5 a.4 Pee eC Re OREO Ee ea eee eas eae 95-95 66-2 Signs :— [DYE ook G Geta NOE SEER REO COOLEST CP er Sere Ee ee ee 66-10 to 66-14 TE Sait so 6 ora coca He Ra O eRe cae aoe Scene 66-5 to 66-9 [NTRS GICAOG ysl einsolcicc. Be Dee or CODe Grind ciao nats sain res 66-15 to 66-17 Bloomin catin oeeseer er preernet as hoe eo antes: Geyer nceae aa sie ae Ae 66-18 See Lighting, Exit, General Index, for details Live Loads :— ASsemblysroomstixediseats: /OlbapersGeit.......+..-45-+5-45.00-es eee 70-1 AWesemblyspace; no ied seats, 100lb. per’sq. ft... .......-2..c5.0---es: 70-1 Billiard rooms, except spectator space: 50 lb. persq.ft.................. 70-1 Bowling rooms, except spectator space: 50 lb. per sq. ft.................. 70-1 Bustenuimalispaces|OO0Mbapensgeits. s.aacanceceaesada e+ a+. osc somone 70-1 Conndors OOM bApersa Girne ts Gem aceite ces ie cena anne ceva 70-1 Bxinibitionroomsstixed!seats: /olbapersqe fits. .. 625.2. 1¢ suas esse eee 70-1 (Grey eral pwr ea e ey soe Sega Sera siiec 1h) Phi ego ea TL es aaron Se 70-1 Gymnasiums OO bapersamiityaewer yee cee ares rete eee oe riers 70-1 ERoollrooms, except spectator'space: 50 lb. persq.ft.............:..:.-.-. 70-1 Sianmwanes ICOM os aes piths. aches eeodoundaosnuonc bo psudesdoeseeecor 70-1 POG KGTALOOUMG CUTE Ue fe ysis ro tteests oy Mesos aca tae, ons) em meee eee 55-3 Wocksvexit open trominside without key, .5..--4.--22-¢.0ec2--sonee sees 55-79 Wodvemnallswcapacitytacton lO): 36 2 eras avis clepueteiaeaacia ears oie aye eke ose 62-3 Meetinrarooms-scapacity, factorsOus-5 4- ce ee eee ne oe oer cie 62-3 Metal frames and wire glass:— (Ganeiell.. a.adioeeo ee eec teeter near Ce apo aes 61-40 65-3 65-4 Sian? GaClesineca hs eee sae ie cent ioe sina ene ee koe Vaan 65-4 See General Index IMovangspicture booth, enclosure. ...4---.....095+62s5-s0- 55-20 3-21 Multiple Occupancy :— ASsemplyehallse 2 hr. Separation s « 5 : Sikes Cine evan 1) To tere SIPS nt echt io ean ee Rermuittedionlyswhen necessary. ......-.-------+2+20+->- PUI. imei, fo) Titles, Gis a old elon pelea ORC ee oe eo ea ceed VAtdnoeel SERIA pEE MOO! CAPACItY cn <2. te ee + tops tae He eee ee NCE est tMORITAMMUITIER Sync. sores aitensia seve Gales hexese ese reuse Amiel TER SC HOI acts goto eee diac Teen ao Oo a cce aoeiiee acre Assembly rooms: See under specific items Assembly room separations............... 55-11 Balconies :— Exit widths: Over 250 capacity :— Passeyees, 4 itt, Wises secon ad amacnonncaneecnoos vote vedo aenoues Sieniies, 4 vith TANS 37>, 6 eee eon ee cee es eee Exit widths: 250 or less capacity :— iPnccayaes, 3 ik, Wall soe gioco oboe a) ier ond rs renin on eee ee SiMe, Bites. Tavs er erage cess cece cee eee ceria sie ote cme Fireproof construction :— INomoord evelalimiitereyec acta: cee ccs 6 dee me yas eee cen Onevornmore:balconiesspermitted. .55...-.-62-+s-s sees Semi-fireproof construction: Audience balcony :— il jDeTmMNWSEls 6 6b eomlo moda oo Bada Aorerie rnc Te rae oOo Pais pCOMMOTeMunanmeHOOm © 4+. aa. nara ne seas 2: Nose Mayshaveyportions atdifferent levels.......:....-..-.2.. Ovenappinesprohibitedtyy see seem ones emer e - SOR tpMaxerADOVEFOTAUCs yo choca oc cac sce eis essere Hie Heavy Timber construction :— AMudienceibalcony, prohibited... .:--0-c.-2<208207 +508. 6: Choir balconies up to 300 sq. ft. allowed................. Choir balconies:20ft; max above grade... .....2-.2-5-..- Organist balconies up to 300 sq. ft. allowed............... Organist balconies 20 ft. max. above grade............... Ordinary construction buildings :— Mudience balconyaprohibitedssn4 ses. nes os. ce nese ees 2: Chom balcony up to 300 sq. ft/allowed..........:........ Chomibalcony 20/ft. max above grade... .-.)}...°24.5...-- Capacity :— Exclusions, foyers, corridors, lobbies, etc...............---.- Pacionrs © ana pIW Ge odes od oocuecn cop ace oanednod aoboas ue HactousGyvannasiuims / Ok jemn-tsaycen occa ves Waa aS os 2c Generalicomputation. 4-4. 425+ - cmos s 245 eee Tees eae. Roomsmotoccupied atvsame time. 2-2-0. ss45 500-6. 5°5 Ceiling Height :— Assemblysroomlal2 fits Mins... caw ce «aves oe iis ase Balconies out. min- Over OF UNGERs «oe... a. stl Projections below: prohibited). 9... 42.01.46. a20- 5-55 ‘Ganaally d(Oaiies ach Oe ees ome eee a cae. Ann oeiciq mnie Oe Measurement :— Highest point of sloping floor to lowest point of ceiling. .... Level floor line to lowest point of ceiling................. Rroyection 12/insbelows, permutted .<- sa. c..02-4- 4-54-42. .- EXcep trlny bal COMES my enter ols eieiecir orator erne 1 eric SLOMAPCEMOOMM te paces irik nore exeer eerie arene IROL oo NaTS Chae rah iol eee Bem oo ean ln omtod OOOO On abe Choir balcony, see Balconies Construction :— Fireproof construction required throughout :— Over 1,800 capacity above basement..................... If balcony floor, or gallery is over 30 ft. above grade....... 187 188 Construction-Exit INDEX SUMMARY Construction :—(Cont.) Fireproof construction required in:— Basements: Churches over 800 total capacity....................00- 56-4 Floor over basement: Churches over 800 fofal capacity.............. 56-4 Fireproof construction: Omit fireproofing :— Structural roof members, supporting no usable space :— If roof slabs, etc., are 1 hr. construction and are 20 ft. above floor. . 56-4 Fireproof construction: Omit fireproofing :— Trusses supporting spires and no usable space :— When they are 30 ft. at least above main floor................... 56-4 Or, if there is a metal lath plastered ceiling under trusses.......... 56-4 Semi-fireproof construction required :— 801 to 1,800 capacity above basement.........2..:.2ss02s000e teen 56-5 Providing, balcony, floor, or gallery is not over 30 ft. above grade. ... 56-5 Exceptions :— Basement must be fireproof construction.....................00- 56-5 Floor over basement must be fireproof construction............... 56-5 Trusses, unprotected steel, wood framing and covering :— 1. Allowed, when 20 ft. above floor... ............0.00.000000. 56-5 2. Or, metal lath, plastered ceiling under... .......:...00-s8ee 56-5 3. Provided, support no usable space...............20cceeeeeee 56-5 Trusses and roof, heavy timber wood construction :— 1. Allowed, when 20 ft. above floor...........0...0..ce ce eeeee 55-5 2. Or, metal lath and plastered ceiling under................... 56-5 3. Provided, support no usable space..................20.000- 56-5 Fireproofing omitted, see Exceptions, above Heavy Timber Construction may be used:— $00 or less total capacity sc) 5 26 Seu cae eee ee ee ee ee ee ee 56-6 Not over 2: stories high. - 32... 2. se: ce cena ER eed ee 56-6 Ordinary Construction required, when :— S00’ or less total capacity... iiacr lik ae bs nloae - dak een ee 56-6 100 or less total capacity, not over 4 ft. above grade................ 56-7 2 SEONIES OF LESS: Sia 2d ear ed Sees ee ee 56-6 Corridors: See Exit Corridors Curtains, draw: when no combustible scenery..............200-0-2eeeees 56-31 Defined as place of worship, and religious purposes................... 40-17 Doors, min. widths:— xi O Pls WON. 2 ry a:cesaaetaa ie ste ae ees aa ee ee 56-18 Others,’ 2)f€:G.in: Mminiee. as45see ee. Meee en oo eee 56-18 See Exit doorways Electric wiring, independent for each use.....................--.005- 63-5 Exit Aisles, see Aisles Exit Corridors from Assembly Rooms:— Width :— Based on capacity ce... +5. neon ee ot chimes eee es > 56-22 62=2 (62-3 800 or less capacity, 27 in. per 100 persons. < .2 . <2. ae2ea: oi er coos 56-22 Over 800 capacity, normal, 18 in. per 100 persons.................. 56-22 Over 800 capacity, emergency, 9 in. per 100 persons................ 56-22 A it. min.) ,reneral.,p-.,.; <5 otis sills e Seceltene cette es erctte renege ee 56-18 3 ft. min., balconies 250 or less capacity..........0.00cccectsceeees 56-18 Exit corridors, other than from assembly room:— a prohibited: Passages 7 ft.or less..24 4.025 2s,ansuves tent 64-23 Width :— Based on capacity.04, 2a sn wane atantneae Warns eee 56-18 62-2 62-3 LS an. per: 100 Capachty . aa. 's 34 satan wrcmayntioareivaat aes eae ee ae 56-18 4 it. iin... general, 2.4.0.82-9 ok wes ane chee oe 56-18 3 ft. min., balconies 250 or less capacity... .....0.s005:s0e55beedceu 56-18 Exit Doorways from Assembly Rooms:— Emergency, see Number required Locations, rooms 800 or less capacity :-— At opposite ends of room.............0.. 0. ccc c ee cee cece ce ceeees 56-21 Location, over 800 capacity :— 60% of width on one side of room............2...ceccceeecceeeees 56-21 40%) of width on other side.of'room.:.55.4- 4 os is ee ee eee 56-21 56 INDEX SUMMARY Exit 189 Exit Doorways from Assembly Rooms:—(Cont.) Number required :— iment MV AOmMeSS yar TG UITEG a. cre Afer sia) =e sseasls.t mies pate eine oda 56-21 @venculicapacity. 2 emergency required... 12... 0.02. es ene See ees 56-21 Overs00 capacity, 2 normal required. 3... 2.2 00. c nce e eee ees 56-21 Openrdirectly toistreet, alley, by lobby, or. .... 02 ...0.550.. 0000. eee: 56-21 @pen directly to street, alley, by 10 ft. open space.................... 56-21 SopandkedsasmarasypOssib levine mae syle uc reer serie lieve cicis re ait 56-21 Width :— Salon less.capacity, 27 in. per 100 persons... . 2.2.2.8... eee 56-22 Over 800 capacity, normal, 18 in. per 100 persons.................. 56-22 Over 800 capacity, emergency, 9 in. per 100 persons................ 56-22 Increase 10%, each 5 ft., floor exceeds 20 ft. above grade............ 56-22 Increase 10%, each 5 ft., floor exceeds 10 ft. below grade............ 56-22 Sit. TBR onc:0 6G Gate OER NCAA CR CCEE are are ae a 56-18 Exit Doorways, other than from Assembly Rooms:— Distance apart, measured on perimeter, c. to c. lie2rextt soniye 20°7;r0f perimeter. 2.0). 6... oe Geiss dees se ee soe ree 56-19 Nesrexdesromlyarlo OZ 1OL Perimeter... 0s... 2.6202 .6 Cosas ae ense nsec es 56-19 Location, see distance apart Number, leading direct to alley or street, or by 10 ft. space :— SU0Kcapacitygormless e2erequireds 44. aan esas oe as yea ee < 56-19 Overs00lcapacitys required! 9. ae see a. sae nese hee ee. es 56-19 Width :— Bascdsonecapacliymny ean tele cits sc acne sys oeache 56-18 62-2 62-3 Cnmmlativepmencasetolexitem sh een tetas r me eres a aes cae yee 56-18 AS emg etelOOKCAPACITY ans oe a 2.6 os cles cbs cet tienes coh cat rehnaes 6 56-18 SeiapITIN EXT tC OOGWAV S|.) 6 2 y bya oe eis gare gh ac tec sibs se eben 56-18 DaltyOrmesniineydOOrsmoriother USES... 4... 4-446. 45276 ose 6 seuss ase 56-18 Exit lighting: See Lighting, Exit Exit ramps (used instead of stairs): See Exit Stairs Exit Stairs:— Imelosuxemequinedvexceptelstistonya. 2. --.00a- 1 acide cscs cece « vee 64-28 Sharpmntenomanplesieliminatedien a... acces ee neecece- teen. ose 64-39 See Exit Stairs from assembly rooms Exit stairs, other than from assembly rooms Exit stairs to Ist story Exit Stairs from Assembly Rooms :— (Ccrial Oliiaepninepera feet eee ies aoiaieny ieraians ene eee es 64-31 Emergency, see Number Required Mlizhtsmheichtoryl Site Opmeemax. 45 seer pesca acer ee 64-33 Handrails :-— Rt ESCAITS Wl req UITE Ce. ee ey ters reo) ne and sists ie a totay eT sale oe iene ee 64-34 SHiiLOMMatOu oe. wide. 2:requineda.. 0-4 4sc 42 semiodce ce ss ees eae 64-34 Overn/st)2 plus) mtermediatesrequiredi,.- os. -5--+6.--4ss650+-54555 64-34 ero hiie2eitnO sm tOvoalitsyes aromas cies cee A ts. eth cree 64-34 INEwelipostss oit-, Intermediate mailses4-5.5.c5¢56cea- 2s So aamae oa. 64-34 Returmedsandsjoineduto wally enema corer cman sant mene 64-34 Location :-— One directly accessible by lobby or passage........................ 56-20 All directly accessible to outside exit by lobby, etc.................. 56-20 Number :— Zrequiredfromievery: Story below Ist/story...-. o-c-22ss--+eneet ee 56-20 Parequiredutromi every story above ististory..0- 2525-222 - +4 co 56-20 3 requ ed, from room over 300 capacity above Ist story........... 56-20 3 required, from room over 300 capacity below Ist story............. 56-20 IRTEG. Teall Wye BlroIBIC RCO Esa CEO ROR Oe Min Ooi acs CRP ee eek te 64-31 Width :— SOOomlessicapacitys 227m per 100K emer eee net eee ieee 56-22 OversO0icapacitys normal. 15 ims per 100M ses. te. aciee eee ere 56-22 Over 800 capacity, emergency 7% in; per 100........................ 56-22 Increase 10%, each 5 ft., floor exceeds 20 ft. above grade............ 56-22 Increase 10%, each 5 ft., floor exceeds 10 ft. below grade............ 56-22 AR tema ee emer alr aac meac rs sre ottce oe oko rereRne ata eel ene oF eee eke 56-18 SHit-eminebalconies:Z50orless capacity. -aciaceiemcisicni te yl tel ier ae 56-18 56 190 Exit-Lighting INDEX SUMMARY Exit Stairs, other than from assembly rooms:— Handrails, see Handrails Width :— Based on Capacity ans a 2s. cea «ne ehoe eee Hea 56-18 62-2 to 62-3 15 in. per LOO capacity so ccocc 2% aie caine oa ve suinsde and hG.6 ase aye 56-18 # ft: mim, ceneralle prohibited. ye. sn ace.c + seis oa ie eevee epee sl ae: 56-16 Gas, max. allowed: 10 lb. in containers............ 0... c cece ee eee 51-27 Handrails :— Lerequired on:Stairs 3.ft) 61m. or leSs... 42.4 no ewe 2. eects cone oes 64-34 2 required on stairs, 3. ft. Gin. to 7 ft..0 ii, occ bce tes oe ed Serene 64-34 End newel posts 5 ft., with intermediate rails..................--00.- 64-34 Ends returned ‘and. joined to: wall)... ..05 025 code ccc os Seed es eine 64-34 Extend. to front edgé of 3rd ‘tread’. 32 <... ye aes cine se ole oe ee 64-34 Height '2 it. 6m. to 3ut., at front edge of.tread. 5....2..40. cere eo: 64-34 Intermediate rails required, stair over 7 ft. wide.................--05: 64-34 Wood rails permitted yo. nage nye ee eee cine ae eee tee 64-34 Hazardous use units prohibited, except :-— Standard fireproof vault -..yo0 5.06 shee cie gore ie oe a atoll oa cpete eke tee ealeae 63-2 Waste paper storage or baling) -.. alice ds nance, terest, ss lee een eee 63-2 Heating, temperature to be maintained... ...- 2.02... ..0000eeteee seen ce 80-3 Lighting, Exit:— Existing buildings to comply by July 13, 1939.....................6. 66-1 Normal: ;Generalla.7. se. nas sales Sos sacresenne re ee 56-33 66-1 Onifloor; 0.5 ft, candle.atievery point. 2. (sec) asaie samen tou Meee 66-2 Stairs, J O1t. candle at-évery pomt. <...s2¢ 42 0s esos tk tend eee 66-2 Additional required :— In assembly rooms over 1,800:capacity: i222: ne sass sass Hoe 56-34 In assembly rooms over 1,500‘capacity:; 2.00 i. sss ego ee 66-3 56 INDEX SUMMARY Lighting—Signs 191 Lighting, Exit:—(Cont.) Additional required :—(Cont.) Sontrolledun principal entrance only... .... 22. sc.0%2s...22ss0+-050% Signs, see Signs Live Loads:— nN 7 Ww ASsenalalky moons) IO OU Ee seecCbteanemes poedesdoo ads 66 onc an eeeeeeoee 70-1 (SHOiTPrOOMS wOOPOmpeL SCs kbar as.aevs as ao sign cise sors Glo OO esse SaaS sino 70-1 Class moons, Sin; pres ih te Ape Aomori esti co aicie ioe eres eee 70-1 Spacestuatheuxediseatsyo dbs per Sqeat-se see arenes ore ae ok 70-1 WSSiicy RED aos DUNES oo ae [om Re a ee 70-1 Srempunicrooms, 100M, per's.: ft... 2 c0sc. ot inclecs sts ase sole 70-1 Grcrmanicspaces, 100) tb. persq: ft....% 26h j. sees ge eee eee el 70-1 Metal frames and wire glass required:— WME InBOZRiEOMmlO times 27.5210 ot) ah ors tw at de rete atte Ola iaeleees ae 654 Name Asitrotoppositeside olvalley. ...-- c+ -e soa4-6 See eae a 65-4 Excepuons doubleiglazed windows. .... 2.0.00: o6.e.+us.8on+foee ask 65-4 iMiotion Picture Booths (See Projection Booths)............ 0020: 0s00+%5> 56-15 Multiple Occupancy :— /ANctermall IK? ROCCE 3.6 ooo goto aemooeEeanoe 55-11 63-3k 63-6 BiisinesSeiiae whi SCPATAWMON ye cincie cid cms aise selec eiersemenuetee ec evils 63-3k DaGrsweOmMIMUnIcatINg. .<.6cccicesciss che eee ess wraps 63-7 64-7 GanaceaClasselepronibiteds) cai cacres the sen = Se eres Geemarc nares wieleions 63=2 OvemoUOIsamtapronibited secieico- vce scott ors tare Seeks one 56-16 (Carica ee Se 56-16 56-17 63-2 63-3k Hangar, non-fireproof, prohibited with church.......................-- 58-13 HavaLdousmsesumles pronibteda ya ssey esac see asc steno hela ore 63-2 insitotionalgbuilding Zehr separation... a. 4-o2.- uae tose ea 57-16 Balconies: Need not exceed 8 ft., above or below..................0005- 57-16 SY, INDEX SUMMARY Ceiling—Commercial 197 Ceiling Height:—(Cont.) Cafeterias, no mechanical ventilation: 12ft.min.. ............-....--- 91-25 Cafeterias, with mechanical ventilation: 10ft.6in.min. ............. 57-25 Cafeterias, lunches from outside: No requirements...................-. 57-25 Classroomssvanrea 200/sqeitaonlesss 10ftsmini. oc. -....a-0.--<--- +e. 57-23 Class roomsmovier200isqaits U2 ifthe min. .)s 456. 0s oes ses ee 57-23 Grrmming simian 174 ite a CoV tet Se Geet on Be ee a ae See Doon Iai Gee Rene en 57-16 Measurement, floor line tolowest ceilingline.......................-:- 57-22 lPagy moons JOE stirs he ernie aetna sola c oad Gated crs cicio ee aici eee 57-26 Erolechious permitted 1'2in= below, ceiling... 44.0205 -4o.00--4000se+55- 57-22 RECreaoOmmooms-yt OiitetMINs p22 son jo. ve ers Sie annie mee oe echt 57-26 Rooms serving food :— Wunchestromoutside norequirements......-2-2-054-0¢8+++ee22se2- 57-25 Nommechanienlt ventilation: 12it. mins. 22. 0.555056. 2 2620562 2 aes 57-25 Wathimechanicaltventilation: 10ft..61m.min............5.......+5- 57-25 Srudvwnoomss200/squit.orlesss1OHtsmink. 2.3 ..2 4.5 45-2+02 5-2 ee cele: 5/-23 SLUGygroomsr over? OO Sdaitaelattaminls..... 26 vate ss gasses one ns cles = 57-23 ‘avila maoraas OTS TCO Oe Ae cane re Aree ei Pere ery cee cee ary ae crane oh 21-27 Classification :— IDlementainy, CHiss keds abio-eo Patents chime ake nh ae ares eee eae 57-2 IBtiedn SelAGOS, (CHRIS Le lek Sree ote Tepe eo eed aie cee ee 57-2 (Calleaas, Chins IWC sae ale Sein Cee ope aie a eae cee nanan ee 57-2 (Commencialme Classless nese y. soe elo nematic cie eae annie levees 57-2 Hire PATACOM LAS SSI pee cr pnnrI Nr ty ey yet. Ni nc a cbecearacariee oA (eer ne Recluse eee 57-2 NMocabiond lm @lassiiltemm airs ae cree act iste eee 2 cc Sco tican go aysnn ames s o/-2 SiMgledwellimpeansittim olessithanelO: fs ie esse Seite seers ne cece see ae 574 Class Rooms :— Aisles :— 1-18 in. aisle required along each wall Cross aisles: 30 in. min. width Teaching amphitheatre, excepted, which see GaMacikypactOwml Grain eee eyo ck serrate ete INT Reich Maier states eteens Doors, outside exit :— Sepminedistance touotlines 5, «scan cts seein al oer ie orale seek Increase 1 ft. for each story over 4, Class I school.................. Increase 3 ft. for each story over 4, Class II school................. Exception: Facing alley, street, or public space over 10 ft. wide...... Doors required :— 800 or less capacity :— 1 leading direct to main corridor, or 1 leading direct to outer air.... Over 800 capacity :— Ppleading direct tovouter air orimaim Cordon: o...4-2 426222 a6: iBxception: may lead torothericlassiroom’, 242 4.9. 5-5. 42-22- 5-4 Wii thapmninse Zeit. Orin vessiy chavs ttyierens the eee meee TA Seto oe ne te cles Illumination, 5 tt. candles on plane 30 in. up iy eploa dao OM per SG ktacu cts jstocyachstet ce uismechom ous een eel tl a ire Ventilation, choice of 1 of 2 ways:— ipeNetopeningvarea, S75 Of Hloorared: «---- eee serine cee 2. Mechanical ventilation........... 57-64 65-2 Windows, required :— Seitemminendistan Cestonloe linens cre eer eee cca etemiioe eeateene ee Increase 1 ft. for each story over 4, Class I schools................. Increase 3 ft. for each story over 4, Class II schools................ Exceptions: Facing alley, street, or public space over 10 ft. wide..... Closets, prohibited under stairs, non-fireproof buildings.................. Collegestarey@lasseilhs Fy cyactic sec a deste Wrensisioracsh: Oh cease ye ae yerayeua eee ks Combined Class I and Class IT schools:— MirstzcontormatouGlassslCodesaace cer ee mike re era icin he aioe Except: If separated by fire walls Shall be separated from each other Commercial schools are Class IT 198 Commercial—Elementary INDEX SUMMARY Commercial training rooms:— Partitions, rooms 250 sq. ft. or less:— Glazed from 3 ft- up to / ft..6\1m.... 05 2 a. duce @eeans Noe eee 57-24 Height may be 7 ft. 6in................ A Orta + he eee 57-24 Ventilation, same'as class rooms... ......2...005. a2 i¢e.00.00 eee 57-24 Construction :— Annexes, 1 story, or 1 story and basement :— Unprotected roof steel and columns, if :— 1. Used as assembly room, gymnasium, etc......... 57-14 61-51 2. 1;500;capacitiy or lessice.. 2 4eu es ole woe oho 57-14 61-51 3. Principal steel, 20\:ft. up... 2. ..26 02. .eu.ee. os 57-14 61-51 4. 23 in. roof sheathing.......................... 57-14 61-51 5. 3 hr. separation, 60 min. doors................. 57-14 61-51 Basements, floor above, 3 hr. construction..............%..+0-e++e00 57-13 Fireproof required :— Over 4 stories highs. 2 = 2a sance nec een stun ages cee ocean avant 57-10 Over 50 ft. from ‘grade to 4th floor... ..\....-0e2 eee se ee se veee Dome 57-10 Except: Omit fireproofing :— Roof members over 20 ft. above floor.............00...022.00005 57-10 1 hr.construction for roof‘slahs; etc,. .0......¢0sa.0-+600 or less capacity a... 2.2.26 cee ss oe ae ee Seon 57-12 2 stories or less: 200 or less capacity... 0.0.0.6 eee eee 5/12 Assembly-room must be 600 or less... 0. ccc5 soe ass Ge ee scaue ees oee 57-18 Gymnasium must be 600 or less..... 00 ..000000 0020 cece ee 57-18 Except :— Floor above basement must be fireproof.....................00.- 57-13 Portable buildings, which see.,5.440....2ea 0.064.040 sesn ee eee 57-15 Portable Buildings :— DSSLORY ODL 5s: aioe, so eee retest ee ee eran Oe Re one eat 57-15 ZS LE.) Dy; Sorts MAX. /SIZes wes se aerate ait eee nena 57-15 10 ft. away from any other building.......................000005- 57-15 2 years limit Onitise2. 2. ctasoc a ois ee ee ee ee 57-15 2 exit doors, separated by small building width. ................... 51-15 Non-combustible roof covering. 2s... .244..44 54-2020 ddece bees 57-15 Usedas school onlys2e2 2202 aes eee ee Lorn eee 57-15 Cooling, 6. pt taccst cee ee ee 57-77 Corridors: see Exit Corridors Crippled children :— Elevators: Area: 4sqoit. pet person. foi... 6ac ane caccssuseees eee: 57-55 Empty in 20 min., over 2nd floor... .. 6.0... b heen c eee cso s anne Sepes 57-55 Required: Floors'over2nd S.aeecess. ee eee eee eee: 57-55 Curtains :— Draw: No combustible scenery. vag... vac .. nese ona ehe oo ae 57-70 Fire? Combustible Scenery sos osu see eis eee eee oan ee eee 57-70 Defined.as place of instruction? ... 2.400.005 e+e fece tes se oes 40-18 Defined as single dwelling, sitting 10 or less................. 000 cee ceeees 57-4 Doors, revolving :— Permitted, Class: El schools; in addition. «ccna 0a. sn s.eetos See aon be ee 57-54 Prohibited in Class I’schools: 24222 5..'2 80 anne ald ieee ee en eae 57-54 Drinking fountains :— I for each 250 students <. ..0.c0cs >. senenuete cancun Giese ees 57-76 Tan CaCh: StOry a4 cas fecnt Wok se a ines nase a ee ee 57-76 Eating rooms: see Cafeterias Elementary schools are Class I oi.35.0.%.¢¢ne+s04 2446 sa.ue 1 as keee ate 57-2 By. INDEX SUMMARY Elevators—Exit 199 Elevators: Crippled children’s school :— PNTEAEL-LES CML baa CLEP ECLSOMM ey cr. icrsyacfeveie oi chwicl d sfvtavoiaroke Se Save MME we 57-55 Bmpiygnoorsjabovernadvn 20min sk oe. nes cose ss sees cisco see} 57-55 Required stomsenverallumoorsioven 2nd. .... 4.5.60 0s2aqeee sass esses 57-55 Exits, Cafeterias over 800 sq. ft. area:— 2) REGU! 9.5.6 5'o.c.o-o.0: bb ERED tb i LC ae eR 57-58 Distance separation of center lines:— FOC Hot perimeter On, perimeter: < ) .cs-r.s-d< 0 s0c0 se - 57-37 57-58 Woorsiswanemmmecnessidirection. 4... .syek sade aenes se aces cones: 64-17 Wicdubee Avatar per lOO Capacity, .5 5... «cic cocoons nek oaceiete see eo cee gers 57-58 Widthyonitomnetonrstaimway, Generales... 0066.6 -0-e.0-es6cue. 52 57-32 Width ant qOnnerormibaseMment Stalnn. a. 22 ee eie cere. 6 am. 57-32 Exit Corridors from Assembly Rooms :— Width, when over 800 capacity :— DURE EEO MDERSOUS U5 ¢ Aires aie ashe adc aisle Cale Sista a nce acon eae 57-38 Increase 10% for each 5 ft. over 20 ft. above grade... S7-17 57-38 GplitaeraTMe MOS tLUGLE soc ys de ees ae oases asians mais se ore hve 57-32 Exit Corridors, other than from Assembly Rooms:— Weimedkasumainrandisecondanys). «. . .sl-tc)cscleciscaedeee sees os one ee 57-33 Doornot permitted to/obstruct main corridor...........+..--....6.5- 57-36 Door permitted, not obstructing main corridor when open............. 57-36 Doors permitted, shutting off independent sections................... 57-36 Lockers, doors open or closed: Must not obstruct..................... 57-35 Main: Defined, connecting student rooms with exits.................. 21-33 Terminates directly in stair access, or at right angle to stairaccess..... 57-34 Obstructions prohibited: Passages 7 ft. or less...0...5...0.0.0220.00+%- 64-23 Secondanywother than maimiGormidOr.......5..0.05s91cnee dso snse scene 57-33 WacdthesBased on) capacity... ... 2.2... 57-5 57-31 62-2 62-3 Shines petal OOsMeTSOnS May ey ten nota ie ao cee oe ners domsiceh cardio 57-31 Ohemmin. unobstructedimain corridor. ..........<.02Psn.es6. ween 57-32 Exit Courts:— Doorsjopenteasily trom) inside; mo key* . 0... 6. ace0se0nsse2 seen - esses 57-57 ELeie item Op item OMNI sae cE) sie tors 5 .e/r16.c 481 Sega ce ope MeL ctl isis ole oe 57-57 Lead directly to passage to main stair or corridor.................... 57-57 SMaMlepitEGIECCELOM-Of CRTCSS 828 sm )e lease ere cb sie ate g Pe duidaieis ees ee eae ee 64-18 UOAVCTE i SI iCGs 100 TA Ree each a ee ee 57-57 Exit Doors from Assembly Rooms :— Location, distance separation on perimeter :— ie2erequireds4 097 Volaperimeternr. s,s 1csseid srciaes edo ele see eee 57-37 If 3 required, 1 distance 40% of perimeter......................... 57-37 Another 2 ,at least 159% of perimeter... In’ which students'sitin banks...5..2..:.2.<<<<06.-00.003+ 57-42 Raise; 20 or less capacity: No requirement. j.......2..:-....¢.c+aees- 57-42 Ris emOvely? Olcapacitys Oline maxes Gee eRe ace nisiies ane noeuae sic 57-42 Stairs, width :— lS pip petal OOMPersOMSr eer: seen oy Mace ae eae nre iciate os tcvencic 57-42 2 Siiby OSTA ATEOUT ORME ratte et ley ctr ry Mee Mey Sane Epitope a ARTs Oy Re ea 57-42 WwAndowsS exe tONMSHs-styocnc a cies Comte. 8 prio eon ee aie evchaeaec 57-60 Memporanvyaportable SChoolss oo oc se acces mccain aes ances 57-15 Toilet Room :— Doors, 20 ft. between ““Men”’ and ‘‘Women” doors.................-- 57-73 Drnkingountains prohibited: ~~. 5.25.62. oeets asses chec mass - 57-76 Fixture calculations :— ASSemblyaroomMs not Counted rm erase eerie eee ocean 57-74 Gymnasiumsmot counted ses heer ere eer neni cea eee | 57-74 ILA GNKOMESS Ist CHOay WoO NS | Goon mangpoecamonubeodAbbuadahos 57-75 Required, in each story, or above or below that story................. 57-74 SeRPASSUIMEC eACMISEK ana) oe cucpaee butiaie oe Smee y vey hee cdots NRT tne Lae 57-74 EXCEPt SIM PLE SEXASCHOOIS 4 tua aisdsiscascen sno STM ee Tate nner veut ee 57-74 SIPMSMP AIL MARKO 5.2. caicra clean nts subdue ae hice era Chad cise nt wideecsies 57-73 (Wrinals pisforedchy2oumales: sh fcc hic 2 saiol foes, pees DA Re « citeoloe 57-74 Water closets :— IiOTAcaCheZomemalesepra.s conis ee eee errs More kiee ovo koe Ora ote: 57-74 IELOTeACH ESO MM ALES A eins kotcks eo cient ache ee ene ae oh ae ead sie oeere 57-74 Ventilation :— PNSSETIAE) LV BTOOUIS EWey ey Soe ee rec ciei Korea Ne en teva ne Eictene Cos ee ie Bin ciao 81-7 204 Ventilation—Windows INDEX SUMMARY Ventilation :—(Cont.) Class rooms, either one following :— 1. Net opening area, 8% of floor area, or............. ccs cece eeeee 57-64 2. Mechanical system.............. 0.0. c eee eee 57-64 81-7 Cafeterias, and all other eating rooms:— 1. Glass 10% of floor area, $} to open... 2.2... ee ee cee ee 57-67 2. Mechanical ventilation, food heating rooms..................... 81-7 Vocational’schools are Class IL... 2. .c.s cco dee ss sss cede cuane dee 57-2 Windows, class room:— Ceiling light under skylight :-— Increase skylight by:29 9-8 ee 5 cesnk tsa one enna s tetanic ee 57-63 Must be’samie area as skylight. 20.0202. 04-4). ccsie paride eta stomieaes 57-63 Distance, to lot line: 8 ft. min. Class I school............0...0.06.008 57-9 Aft. Class LNSchool Measrraar cae tee eee eee ie eae 57-9 Exception: Facing street, alley, open space over 10 ft............... 57-9 Increase 1 ft., each story over 4, Class I schools.................... 57-9 Increase 3 ft., each story over 4, Class II schools................... 57-9 Face, alley, street, public park, yard, court............ 57-59 57-9 Glass area, Class I: 20% of floor area.... 2.2... .cs cece ce cescsencse’ 57-60 BU, tOiOPen.ssGe ee see he ee sree chee ie ee eae ees eee 57-64 Exceptions, possible :— Demonstration Looms 2. ose S0s) oie Soha ase eee eee carmen 57-60 ADOFAtOTIeS. 2.052050 440 ee pad Pees kde are Sepak f aonteoate cmt edenate 57-60 Teaching amphitheatres 34. sacs cs cise ees ere ieee erie ieee ae 57-60 Glass area, Class II schools :— 10% Of MOOT: Are arsnnec ct eee cee ee ee eee 65-1 8% of floor area to open, or use mechanical ventilation 57-64 81-7 Height.-Class T= 3 room) widthinn. «2. misc. aor ce see ais tere ne eee 57-62 Location, Class [:all.on 1 side of room: . 2. sc... sme sen os seas ence nek 57-61 Skylights may be used instead of windows....................00.205- 57-60 Windows, stairway :— Glass area. 1:21Scy sat bao cys com tees tere eo eas, RE ecco 57-65 Type, As window required 3..%.24:.cae.-: .7a.cls Sete erence ae etree ee cir 57-65 a7 INDEX SUMMARY GHAPRTER 58 OTHER BUILDINGS AND STRUCTURES { at t * — INDEX SUMMARY CHAPTER 58 OTHER BUILDINGS AND STRUCTURES Includes (See Sec. 40-19) :— Billboards Police Stations Carbarns Prisons Exposed Metal Structures Railroad Structures (special) Fences Sheds Hangars Signboards Ice Houses Stables Illuminated Signs Tanks Incinerators Towers Jails Billboards and Signboards:— Nterations-seermit requirediy.. .- 1216 oc bie ee on otc oso eee bees 58-71 Anmi@all imapeehiom mxouinel S pepaeaoseucs deadacdous sno boauUlsbaeeo- 46-18 Bend 925-00000: Required from erectors. .............02.000+-00085 46-22 BOLOMP Rem OnMeaADOVe Streets Olea] seek decays ss oc ac cee cases 58-69 SutTOuneabovEercround. 1 higher. ©. 4... scc0..ss0ees ose sees e = 58-69 Com. of Buildings may tear down or remove..................-20000: 46-20 Construction :— deere NOR COM DUST Des. can i aie oo cle cicleim ie are we mole Sn se ota eS lade oie 58-67 CEPteeasdattasions lor oale or ease’ 2... 5+-+4-2 0-2-2565. 2: 58-70 Supports: Stringers, uprights, braces :— Steeleslignotasolatedml Oita ss mec ce acco sce tee oan 58-67 COGS IN Tee) Eis OE 0S 1 ae eae en re 58-67 Wind load design requirement :— Ppl MPETaSCLtrOlSUTEACE = x 8s, sya las1t ater s ays <8 nalehs, dt0soa/ea «, 5 01s IE 58-67 SOM beperSGarkt Ol SUTaACe as ee ataitold-auewie Nove qapee brn sie og Sask c= 70-17 Definitions :-— . iBilvoards-Outdoor display of posters. . ....2 0... 0.2¢se.cederceses 58-66 Sigupoards: Display other tham posters. ... ..o:..<2..o ce oaeam ene eee 58-84 Exposed Metal Structures :— Includes :— Canopies) ax. 46-5 sae See Bet eos Che eye caterer etal Seas 58-87 Chimneys,metall’ we.c.ic.s ase eee eee ee ee eee eer 58-87 Metalsstacks)s .....2tai2b siete ceioeiee cron ieee eee 58-87 SISTIS a5: Fe RA eae never A Deere eee eee ce near See 58-87 Smoke: stacks: 2 tuctens eo eel cin sees eee eueteyes = ee feereepicie eects 58-87 Inspections required :— By licensed architect before July 13, 1940... ....... 22.2006 se0 cts euhns 58-88 Or by licensed structural engineer before July 13, 1940.............. 58-88 One.required, similarly, every 5 years..........--222 22 eee ceeeeees 58-88 Report‘in duplicate to Dept. of Bldgs: - 22... 0s.0.s nopees es eee eee 58-88 Maintain-in-good condition: ac sce hens sete eee ne ere orm eretoenclene 58-87 Notice’ to repair Or TeIntOrCE cae recuse sree oe niecls aie esis ers cine ere 58-89 Paint or metal coatings not protection... <2. 2516.52 2. nee snenseee ee 58-90 Repairs, removal, or reinforcements. 2 o2.2 oe aoe a 2 teens oie Sous ieee eae 58-89 Wind load, 30 Ib. per sq. ft. of vertical projection...................- 70-17 Fences :— Construction :— Height: Vision obstructed under 50%, no limit..................... 58-81 Wood: fence..8: ft limit: 20, « ha a cya epaet tee 58-49 INon=Fuel-Fared., .... Detistrstas crop eee Aerie ok ome ae ate nes Bs SMS OS 58-49 Defined as burners of garbage, rubbish, etc.............2..eslieenee ss 58-47 Fuel-Fired :— Construction :— Burning 250 lb. of refuse per hour:— 8 in. com. brick, plus 43 in. fire brick. ..244.. 0. esse ums clei 58-56 Or 33; in. steel casing, 4 in. com. brick, plus 43 in. fire brick...... 58-56 Burning over 250 lb. of refuse per hour:— Sin. com: brick, plus/9 ans -fire bricks)... -.sr., 1.2.0.2 aeanchs aoe erey deere 58-56 Or 53; in. steel casing, 4 in. com. brick, plus 9 in. fire brick....... 58-56 Chimney: Construct as in Chimneys, General Index May connect with 4 times as big boiler breeching............... 58-57 Design for high temperaturesirequired. 3....60555. oe sence veto: 58-36 Separations: 2 hr. construction required........... 55-55 61-84 45 min: door ‘required: 3.2.6 erecta tat vce aa: 61-84 Type A window reqilired:.'; seis es eee oan Ae 61-84 Defined: Having fuel combustion chambers..................2++++- 58-54 58 INDEX SUMMARY Incinerators—Prisons Za Incinerators:—(Cont.) Fuel-Fired :—(Cont.) Wocarion= Miustbedn separate TOOM =. 2. 2.0.26. ccc ns eee nese as xcept wAllowedunprleatingsnoomS 45. -0as0.-.0-.c0+2---202 + Retisewbinsy(Momchuterilled)in.. aans5 cee ewe oe seco ees. ssn. Deiiaseparation req uinediatherwisesaa4sss-c6esss: 2 es-s- s+ 5+- Refuse bins, etc. :— Meatyabennesame roomlasyncmeratote ..s0s- ese eee s-- eases: BexcepEwhhosemedsnveretuse chutes maaeane. ees ss sens cea so Refuse chutes :— Discharge into incinerator room prohibited...................... Btensionyshnroughsroorrequinedie.. ac. a2 sac dee ss a cae es se ene - Houndationsror masonry srequired.:.+.a4hceqceaecsass «2 oe-s eee nee Seqwiceopenings: 45)min. doorequired...j2.:0-04--+--6---+--:-- Skyjlightawithware glass required s....4--94-2-02 2+ +s0n-cc----- Bxcepiavnere metal-ventilatoristuseds.-5...+-..02+2+s-s-4-% Terminal rooms: 1 hr. construction all around.................... Wallissouns brick, or Olin. Reinforced! Concrete. ..............-.4- Non-Fuel Fired :— Chimneys :-— isenviceopening-| blues t1s.in. diameter... .2.....00-.ss-.c0.--- 12 service openings, 6 stories or less:— i mespilosaimeanediaMetenas chs cas onteest menses s heee ee wee < Over 6 stories: Flues 171 in. in diameter........................ Construction: see Chimneys, General Index Sadgeamesvemrequireds din; mesh... 2.3... .0.5. 5005+ ccpeetes sees Construction :— Grate area 9 sq. ft. or less:— 32 in. common brick, plus 43 in. of fire brick................... Grate area over 9 sq. ft.:— Shinsorcommon brick. plus'4> of fire bricks.) ..5..9--+...-.--- Defined: Using fuel, if any, for primary ignition only............... Separdiulons 2p ar- construction required): \..24e.%-06 st0.922eeeee4-- Service openings :— NreammottOuexCeeG: syle ATCA. .2..24¢28 5:55 aedlss yeececensaccnns @harcimgedevicerseli=-closingy ck certa sera tikes eee it credsietere) to reer te Inclosineswallsitany, non-combustible: so. essec.ecs- ee eee in ele Defined: Roofed structure, sides at least 50% open Stables :— Construction :— SANG PEFACHaptenOMandiO4.s om sit eee oe einemetecie maces ie Storaremoommtomuays ELC hraseparatiome se ee tes cles eee) send er When 2 or more animals: Drained floors required Defined: Housing horses, cattle, etc 214 Stables-Tanks INDEX SUMMARY Stables:—(Cont.) DD FAIA GE’. os secisa he's s Spel ‘elanord drole s seotermieig © oe) deren aha Siderite ae 82-105 Electric lighting only permitted: 22.2) o..5. os << neds 14 eOeee 58-41 Exits, pedestrian :-— 2 required, ‘over 9000:sq. ft. areas. 3). 6c. secs coe bared Ee 58-40 Any point, 150 ft. max. from exit. <3.4.: 3.. 05. #5. 5 ee ee 5840 In addition to “animal? doorsises 22... ns es se cn ee 58-40 Located at opposite ends of building. ........2...32... 2 eee 58-40 2ramps or stairs requited, over I story high......: .. 1.2. ua aes 58-40 Except: 1 may: be fire escape.g. .2..0 2. aes os see o cece eee 58-40 2 ramps or stairs required from basement... .. :.. 2.5.0... eee 58-40 Floor load cards requlired)....oo% 3 226 wide ss 00a smc oe ~ oes ty ee 61-13 Frontage Consents)cc . . Sec cee deg oldie oa) sigs oe pase 1 ee 59-18 Hay storage, etc.: see Storage Room Location, over 8 animals, or area over 500 sq. ft.:— 400 ft. min. distance to:— Chure hiss. cities sisters sveiseste oon nt or Ad ode eee niece Sp nie et 58-37 Hospital sc.s 0 eces cn @ scabs te e30 s See hus pe nate ones cs have OOo 58-37 Public: parks, 03 24 sich otcms 6 et Netcare Sttecra Gite cand Oe ee 58-37 Public playground)..4..2< .ac%sso-naale hed atin a's emnave oh een een 58-37 School fs sain. cancdetin ee wees de tacictac nee aad inks See eee 58-37 Location: 60 ft. from grandstand or bleachers....................004. 54-8 Multiple occupancy: 2.5.2.2 .:.6 ssc eck se sede oe ocean is ocd eee 63-3m Storage room: Required: Area over 4,500 sq. ft............... 0000000. 58-39 Separation: 1 hr. construction: .......00.. ¢.s6-a.s0eeu aeenaet ene 58-39 Tanks, roof:— Annual inspection required)... 222.5252 s0s8s5- sna wees 2 Se os Gee eee 460-44 Date plate, rustless, required, tanks over 250 gallons.................. 58-87 Fees: Annual inspection, $5.00. 5. a.o2.0 sc cen oo 00a ee 46-45 Except: Based on area, building inspected annually................. 46-45 Fees, Tank construction permits :— 400 gallons orunder $5.00. . ck.n..asncoc nebeud tannin eeeesthen eer 43-30 Over 400 gallons capacity $10.00 ............. 0... eee eee eee 43-30 Fees, Tank supports, $10.00, except new buildings.................... 43-30 Inspection required :— Annual, by Dept. of Buildings. ....222..525.025 2080024505 ote ee 46-44 By licensed architect, within:2 years, Or..).22....22-201:+.<% see. eee 58-88 By licensed structural engineer within 2 years...................... 58-88 One required’ évery S years. 2: aecnec oes Sern. 225s Pans ae ee 58-88 Reports in duplicate to Dept. of Buildings......................... 58-88 Maintained im good condition. 2... 52... scce canes oe eee eee e see male 58-87 INotice’to repair or reinforce epee .c ee cae ere eee ee ele ees eels re 58-89 Paint or metal coatings not protection. ................sese%eneesese 58-90 Repairs, removal,or reinforcement: . 4... .2.:e 4-052 --¢a-e2 52 ee sons 58-89 Supports to be non-combustible, <4 ..t4. 5. e0- esate ete nee see 58-86 Wind load: 30 Ib. per sq. ft., vertical projection.....................- 70-17 58 INDEX SUMMARY CHAPTER 79 ELEVATORS, DUMBWAITERS ESCALATORS AND MECHANICAL AMUSEMENT DEVICES INDEX SUMMARY CHAPTER 79 ELEVATORS Includes elevators, amusement park devices, escalators stage curtains, and movable stages or platforms LNEBIGIETUES , o''a'5 86 4A COU IO DIES CEI ane Dale een meres AIMUSeMentyparkGdeVICeS..... 2 ier ois so tate) =alet eho. eee) alelo ie so 82-58 CHR Gen 10 (DIEIISOSae ee ere Ce PiSiers a oeean ceri Iori Cate: 82-5 Connechionsa Closet tO SEWED. ..2 ne scorer cles oe ae Seales 6 a clelseis clei ( 82-12 BamilACMMmane (HANS 5 oo oaocooouoGU eae oebon ao ss HE boone Sado aos baoducKEd 82-141 iRedestalauninals loom connection... qn sors ke ate oe ete eh 82-142 TEATS COveC) (ho Co Shee aE re Ser ease heres! rrereneses On 82-75 SIO MISIMEMENOOLICONNECHONS «oh o5.6.0.5 a /aie wietnate Me ots spe teres cies esos ois 82-142 (CHOeS Gommechion? DeTieGl b4 popes sumogeseosorocouco sob oopomomcsono nos 82-2 Pirolntl Weck. a 26 Oe ene rd Corea oe mee ora or 82-10 82-39 82-35 WefinitionspotatenmS USeG sees cee aes emery hal eens cl-ieicce teal 82-2 Dewatering 65 cegessagodeneoaepoauucadsonsopadds as po llgS 82-5 Downspouts :— Doran Gia hecna-6 AeA SRC ood BHO OOO Bom eer eda Sanco sod Bon on ue 82-65 imide cast iron, steel, wrought iron. ... ).. 2. 5. setae ee ee ee 82-65 Root Commanoses oonaoceanedsaoucnopossd dose 765 06 bu oeeoaamovoor 82-65 BQRECHEOUIEN OOSCLOTAVEL vote t nn as aleve. aes Breeasleis) fereran sciny oka 0S creo renal 82-64 Sizese Witla taverecay Iiils on 5 5 gouonadodeus soa sennouoHdaooDodane 82-64 Wiithotteimereaserss Mable x crcsery src icicnclsietsierene coer ttoyseereweheccpaltotenet == 82-63 Meapped certain LOCATIONS «5. ..6.c.c 008s «sua ve a clorsiete eneisn ne oe eens sek 82-61 Wccitcmmaste pipes promibited.. >... =< )-s\se- tac eres + lence 7 = 82-66 AMIE ATE SE ne Saisie cy eo os aco SG Pearls ins ovens Sore lie akale eye" elye Sake ye ors 82-105 (CYaienGe OISSy is ts comin dos Somber DUDnOH Cabs Door aaroocepomopnee 82-62 PAOGESROVCEY SOUISC sta 5c ¢-ctereyescteta ony cp suere aie feel ge) nck eres alae Per eget 82-61 SIDES: 6 6 og CRA en Oe eae Ua iG can Aaa stos comets comntinn tec cree 82-105 SySheniceim@ependent.¢ 2ckec.cc ce eer vie ewe cients eeeiel me eseveleiess iste 82-43 Except uldimes‘on same lot. ©. J... eae: fees he wn as ole enol sole 82-44 CroMpsrOmPUUGINS: 25.6% 6) ofa je a eras aie cialiterer ole pemnya austin x clone 82-45 WH swans Ae ae EOE en aoneioh ore Ore roma Sauce Aetna 82-62 WramsrIBacksPreSSUNe VALVES! -...2.0 jo onions: dite cuerwals) abeleuetahstenge eon 82-68 [BEND os a AS oa CLO ECT OIS OEE Roe Oe ES IER Di. Oran Fou o biaptoloig, 0.0 82-105 iByracmaane lileonson Geom anos Ge oroeOu gan sedtombanesaae ar ghoueboscauce 82-106 (CaiINNCE HO) SOs Boneh Cet Oe ROC MOU n DOG BDO. cb ahs BORO U to cum cr 82-12 Batirely, within property lunes. MR. cw: aie see hers vee le ene se 82-19 EIOUSE WEY ESIC UIE C amy lel traces tee alters skates = 8248 82-49 Sizes po ranchespmd ererOun Gemiyesyey t-eietenee reir mene sie seta lare ms ehererel ee ser 82-54 Combinedisewers metab leer ree cre tert tecierte nail eaten ta) sos eel) seers 82-53 SAMILATVASCWEIS, | LADIC. oactrscygjncg 8H Zee aislel sete) ad cin! en dist doin ee ieys ples 82-51 SLOMMNSE WETS ONLY ,, PADICR CALs 3) dace datsnes sco sia bs Aah cane navn eiael eter e fares 82-52 223 82 224 Drains—Mud INDEX SUMMARY Drains: Sub-soil: Accessible: . ssa os csc oo Saeco ass aco One 82-68 ZA ci 001 a ee ee Ae eM tas he no n:c oc 82-68 Drinking CeVICES.. 3... sie's Hern aie 5. og ¥ sien 4s alt ghee pion ae 82-128 Ejector,” water’ pressure... oases. Coens sso Gee ee ae 82-60 BXCAVAUIONS:. 2s seh ws8 Sos ce he ae RU Oe OE eee 82-47 Extension and repairs to’conform’. .:¢:25.- 26.5. ...2 sore 6 see eee 82-14 Fees; ‘inspection s sc6055.<5. + jacana ne + shan toh eee a ne ae Cee Re 43-34 errules Calkins cscs cles 0 < Srei se ey se ethene eee 82-38 Hittings: Soldereds: 0). 2.2 ns ics oe cleionios siseronts sc) aeineress laisse See ee 82-42 Whreaded yo s5 2:5 « syel ceeds eee’ aruda ise ae one DATO e oe eee 82-35 to 82-37 Fixtures: Installation'. «sccm sitas cee ah pale tease oe ae eee 82-112 Meaterials: ccc. a n.c a dvelaus\eyesivatciateaeony he tuatove Grove-cses Mate othe Te 82-111 Number required s2).x ) wnsd4xy Q0R[q-UI-}svQ 93aI9U0D MOT[OF}{[—SIUA eJaIIU0D, pljos—siug ayaisu0g anoy Z SUAHNAW IVLAW JO ONIMAAOO AAILOALOUd AAA uasiappay “A prepay Aq 6¢6T qstIAdoD 93919U0,) uinsdAy 10 ‘auiry ‘yuaUIID “310g WIT [PJ UO Ja}sv[q uinsdA+y Jo ‘awry ‘yuawed "310g YI’ [eI UO J9}seI Ital ON MOTOH—SHUN ALL APIO I! ON pryos—siuy ajyei9u0d 234 *BZ-89 99S ,¥ZSqRIS sod 4s¥9 SsoUydIY} WNUITUTY “ssauyoIy} I00y jooidaiy paimbai jo y1vd sv paiapisuod oq Avur painba jou SI [[J Yons aayM [[y JOO I[qYsnquiod-uoU v JO SsaUAIIY} 9Y} JO SpIIY}-OM} JO ‘UOTJINI}SUOD 00H 9Y} 0} A[}9AIIpP paydde ysiug 100g afqusnquios-uoUu ® Jo ssauydIY} [2}0} YT, °0JI04} patfdde st saysvjd puv YI] [eJoUr Jo Bur[I9 9At}9a3}0Id B Jt YOUT J[eY-9U0 padnpal aq AvuL ssaUyoIY} Gels posinbor 9y} ‘Joo19y} ApisiapuN ay} UO Surj1a9 9A1qQ99}0Id B AARY 0} PoIINbaI JOU UOI}ONIYSUOD JooI 10 1OOY Aue Ut ‘A[UO ANTA VAT}SISAI 91y Jo asodind ay} 10.[—:sSANHOIH], AVIS AO NOILONGTY Ilka a1qasnquiog-u0N asooT 10 pos ,z7 WIM YWIOg eS pesejyse[g ‘[e}uauidag peseqset dq ‘32[ sayoy FIL Mo[[oH ** *sayory Aluosey, pl[os sess sssaeg Aus, POS winsdAxy ‘ajaINU0D ‘QTL MOT[OH JO S}tU) JOP WIM sewer *sqstof “QUOD *JUIOY Torts ssqRIg ‘OUOD “JUIDY anoyY + TIL 91qsnquio)-wo0N ‘gsooT JO pos ,7 WIM Woe pesojse|g ‘[e}UauIdag "++ paraqseld ‘IL saysry ILL MOH sayoiy Aluosey, pros SqPIS AIUOSeIT PI[OS A[UQ SJooy sqe[S winsdAyy "JUIaYy GEIS WIT paniqaios) S}sIof “2UOD “JUIEY winsdA*4y ‘9}919U0D “OTLL MOTO JO SHU) JOT WIT. sqstof ‘9UOD "JUlaYy *SQRIS “UD “JUlSy anoyH ¢ A[UQ Sjooy at SUID “ISP WIT [PW *sdAry "JUIDY 2 S}SIOf [9991S of BUTIID “seq Q WIT [PW } DUD “JUIOY W® systof [9935 A[UQ sjooy **sqr[s winsdAsy "JUIaYy QBS Wy pauiquiody S}slof ‘9U0D “July uinsdA+y ‘9}aI19U0d ‘OTL MOTOH JO SHU) JOT YITM. systof ‘2U0D "yUIOYy SQES “IUOD “JUIOY anoy Z 6£61—Ad0) ONIATING OOVOIKD—S ONITIGO—SHOOU—SAUOOTA—AONVISISAA ANA uasloppray “| prempy AQ 667 paystAdoD yyeT wns BUTIAD “IS BWI" [eI W ,F Ie] “WW ,£ YI sjuIof "déD dk uo “ys¥[q ,¥ 10 ajqnog peddojs-ait a S}slOf [9293S A[UQ sjooy ,€ SUID “SPL YI [219 W } "dAd "JUIaY 2 S}SIOf [9935 s€ 3UT19D “SPI Y WIeT [229 W } dUu0D “JUIaY pure s}siof [9923S A[UQ sjooy “*"* *sqeig unsdAyy "JUDY uinsdAxy ‘aj3a19U0-D ‘OTL MOTO JO SHUN JOT HEM * *s}slof ‘90D “JUDY PEARS SuOO see unoy I 235 RIOD Bla, 93919U02) uinsda 3904S ae aye10U03 youg) P°"d ARID Ai OO Ott ORROINCKOIO “S}lUf) MOT[OF]T pave T SaPlS YO pessyse[q—S|[PD Z AS ie ‘Buywag peoT—aly Ard, WIPEM TPM. UF SPO € ‘sHUy) Z AL et MOTOH— SILL AtID Saplg yIO_ pr19qse[q Wot MOTTOF[—s Hu) azeINU0_ TI@M Ul S[TID 72 WUl 1 MOTTOPF[—SHuy) 9Jo19U0D apts | pess3seld woo pljog—suy ayai9U05 MQ ttettt eerste’ ° -tape| 019190.) re “yulay—aqaiou0?) « °C Sapls YoY pesaysv[g 10 Soq AM ‘W9A snonuyuoy ¢ tl Freee eee eee STB AN MOTOF[—WOUG 18 ae) “TEM. plos— pu FI-89 anoH > "29S RIOD va, ayoiou0) { umsdAy 9Uu0}S EA 9ja19Uu0D soug) PP | ARID WB 2 sqaQ MOTOR pare y UIT [229A BY Spnys [29 UO 1 ete POS seSUCHITE qupete Sel ch ae Ot ttt aoe g-ur-yseg wmsdAéy syUuQ apsuts Sapls YO ps19}seyq 8 ees oe et eens: “MOTTOTT—wNsdAs) at Semis atecineies * = WOTTOFT CINSAAS) SAPIS Z pazeseid ‘TEM USP Z Pog ac eae a ‘ MO[OH—PILL ARID _ SPIS T388Id TEM UF SID Z iB pi Ce ke * MOTOH—ILL APIO GIPEM IT2M USIP € TOPIM TT2M UPSTPD € wo ee reese ess MOTOR OILT ARID Ps © apc Ma oe MOTOH—AILL APD) TYS 299NO , ET SOPIS yO eg (pete isl OOP gpg ack MOT[OF[—SHuUy) 9}9I19U0D avo tt MOTTOFF—S}U, 9zaI9U0D, FA a cae “*** MOT[OF{—SPUQ 9}9INUOD A MOTTOF{—S}U aJoINUOD) 18 “+++ =prfog—sytug ayas9u09 9 Baa siaishe “** *prljog—spuy ejyaiou0Dg a verses? surprg—aqax9u0) MQ trttttess senda. ure] q—a1a19u0") 4S 0) eosye vies: “JUIaYy—a}a19U0D a¥ S) Sven exeueraxeislereyeis hele O Ny ‘ayaiou07d aS TR SOC Rg SaPIS YO posojyselq 7 Oe mer yoLag ST-89 wnoy ¢ 91-89 ano 7 “Jag 29S 6£6I—AGO) ONIGTING OOVIIKFD—=SNOILILUVd ANV STTIVM~HONVISISAA AIA a ee! eel“ Ow ees oonmsomomoao '. ———— wes—— w« 0.05050 ew uasioppay “| paempy Aq E61 WYsUAdOD YT WIN ,£ ‘AOD squlof ‘sapts ae 3SE[d .£ 3 Gre wnsdAD WIM ‘Seid ve Y WET IPPIN IM BUIppnys equsnquro) -uON JO ZuIppnys aqiysnquiog SUOTIWAR MOT[OH ie tee “7 ** MOTOR, uinsdAry SIplS YJOg paseyselg as eee e eee e eee o. * pryjos—uinsd Ary Sapls YO” paeseyseld ak Si0,"e\erefexae ‘ Survagq proJ—3LL AYO ARE eee wees "o5 898+ MOTIOFI—IILL ARID SEpls YO pr194se[q ak ster sss * MOTIOFF—SHUA) 939INN0D os eee ceejia, © ** MOT[OHF]—SIU) aJaIDUOD at é) ye re;e: 3618 *pryjos—siug, 9}919U0,) m3 $\0. 8,0 0,0 0,016 sores -uTeTg-33a19U0D SOPIS od peleseld RZ ea Neeeeeee es oot Re aera: staves EEE 6 Cs L1-89 aOOH | 29S 236 NUMERICAL CHAPTER INDEX CHAPTER NUMBERS CHAPTER TITLES 13 Department of Buildings 39 Enforcement of Building Regulations 40 Building Definitions and Classifications 41 Building Standards and Tests 42 Registration for Building Work 43 Building Permits 44 Building Certificates 45 Building Plans 46 Building Inspection 47 Single Dwellings 48 Multiple Dwellings 49 Institutional Buildings 50 Business Units 51 Hazardous Use Units 52 Garage Buildings 53 Theaters 54 Open Air Assembly Units 35) Public Assembly Units 56 Churches 57 School Buildings 58 Other Buildings and Structures 59 Frontage Consents 60 Existing Buildings and Structures 61 General Construction Provisions 62 Room Sizes and Fire Areas 63 Multiple Use Buildings 64 Means of Exit 65 Windows, Skylights, and Ventilation 66 Exit Lighting and Signs 67 Construction Type Provisions 68 Fire-Resistive Standards 69 Fire Doors 70 Loads and Stresses 71 Foundations 72 Wood Construction 73 Masonry Construction 74 Reinforced Concrete Construction 75 Steel and Metal Construction 76 Chimneys 77 Floor and Roof Construction 78 Trussed Steel Joists 79 Elevators, Dumbwaiters, Escalators, Mechanical Amusement Devices 80 Heating Provisions 81 Ventilation 82 Plumbing Provisions 83 Water Supply and Distribution System 84 Steam Boilers and Unfired Pressure Vessels 85 Mechanical Refrigeration 237 INDEX SUMMARY LIBRARY OF THE OF THE UNIVERSITY OF ILLINOIS NEW CHICAGO BUILDING CODE ee LIST OF OLD AND NEW SECTION NUMBERS B= eee NEW ORIGINAL NEW ORIGINAL NEW ORIGINAL NEW ORIGINAL 9-6 A4701.09 22-41 201.04 40-19 1801.01 43-33 403.09 9-7 A4701.12 43-34 403.12 9-7 A4701.13 25-4 201.04 41-1 302.02a&b 43-35 403.13 9-8 A4701.10 25-27 201.04 41-2 302.02b 43-36 5104.01a 9-8 A4701.11 41-3 302 .02c 43-37 5104.01b 9-9 A4701.10 39-2 2101.01a 41-4 302.03a 9-10 A4701.14 39-3 201.19b 41-5 302.03b 44-1 405.01 9-10 A4701.15 39-4 A4701.04 41-5 3402.01 44-2 405 .03 iit A4701.02 39-5 201.21 41-6 302.03c 44-3° 405 .04 9-11 A4701.01 39-6 201.20 44-4 405.05a 9-11 A4701.03 39-7 304.02 42-1 303.01 44-5 405.05b 9-12 A4701.05 39-8 304.01 42-2 303.02 44-6 405 .05c 9-22 A4701.06 42-3 303.03 44-7 405.05d 40-1 501.01 42-4 303.04 13=1 201.01 40-1 A4701.07 42-5 303.05 45-1 402.01 13 201.15 40-2 A4701.07 42-6 303.06 45-2 402.02 13=2 201.02 40-2 601.01 42-7 303.07 45-3 402.03 13-2 201.04 40-3 701.01 45-4 402.04 i3=3 201.08 40-3 601.02 43-1 401.01a 45-5 3403.01 13-4 201.11 40-4 801.01 43-2 401.01c 45-6 402.05a 13=5 201.12 40-4 601.03 43-3 401.01b 45-7 402 .06a 13-6 201.13 40-5 601.04 43-4 401.02a 45-8 402 .06b 13-7 201.14 40-5 901.01 43-5 401.02b 45-9 402.07 13=8) 201.10 40-6 601.05a 43-6 403.02 45-10 402.08 13-9 201.09 40-6 1001.01a 43-7 401.03a 45-11 402.09 13-10 201.17 40-7 601.05b 43-8 401.03b 45-12 402.10 13-11 201.05a 40-7 1001.01b 43-8 402 .05b 45-13 402.11 13-12 201.05b 40-8 601.05c 43-9 401.05 45-14 402.12 13=13 201.05c 40-8 1001.01c 43-10 401.06 45-15 402.13 13-14 301.01 40-9 601.05d 43-10 401.07 13-15 301.02 40-9 1001.01d 43-11 401.07 46-1 404.01 13-16 301.03 40-10 601.05e 43-12 401.08 46-2 404.02a 13-17 301.04 43-13 401.09 46-3 404.02b 13-18 201.05d 40-10 1001.01e 43-14 401.10 46-4 404.02c 13-19 201.05e 40-11 601.05f 43-15 401.11 46-5 404 .02d 13-20 201.05f 40-11 1001. 01f 43-16 401.12 46-6 404.03 13-21 201.19a 40-12 601.06 43-17 401.13 46-7 404.04 13-22 201.06a&b 40-12 1101.01 43-18 401.14 46-8 404.08 , 13-23 201.06c&d 40-12 1101.02 43-19 401. 15a&b 46-9 404.05a 13-24 201.07a 40-13 601.07 43-20 401.15c 46-10 404.05b 13-24 201.07b 40-13 1201.01a 43-21 401.15d 46-11 404.06a 13-24 201.07c 40-14 601.08 43-22 401.16 46-12 404.06b 13-25 201.07d 40-14 1301.01 43-23 401.17 46-13 404.06c 13=25 201.07e 40-15 601.09 43-24 401.19 46-14 404.06d 13-26 201.05¢ 40-15 1401.01 43-25 403.01 46-15 404.08 13-27 201.05h 40-16 601.10 43-26 403.03a 46-16 404.07 13-28 201.05j 40-16 1501.01 43-27 403 .03b&c 46-17 404.07 13-29 201.18 40-17 601.11 43-28 403.04 46-18 404.09a 40-17 1601.01 43-29 401.15b 46-19 404.09a 18-8 5101.02 40-18 1701.01 43-30 403.05 46-20 404.09a 18-9 $101.03 40-18 601.12 43-31 403.06 46-21 404.09b 18-10 5104.03 40-19 601.13 43-32 403.08 46-22 404.09¢ NEW 46-23 46-24 46-25 46-26 46-27 46-28 46-29 46-30 46-31 46-32 46-32 46-33 46-34 46-35 46-36 46-37 46-38 46-39 46-40 46-41 46-42 46-43 46-44 46-45 46-46 46-47 46-48 47-1 47-2 47-3 47-4 47-5 47-6 47-7 47-8 47-9 47-10 47-11 47-12 47-13 47-14 47-15 47-16 47-17 47-18 47-19 47-20 47-21 48-1 48-2 48-3 48-4 48-5 48-6 48-7 48-7 48-8 48-9 48-10 48-11 48-12 48-13 48-14 48-15 48-16 48-17 48-18 48-19 48-20 48-21 48-22 48-23 48-24 48-25 48-26 48-27 48-28 48-29 48-30 ORIGINAL 404. 404. 404. 404. 404. 404. 404. 404. 404. 404. 5104. 5104. 404. 404. 404. 404. 404. 404. 404. 404. 404. 404. 404. 404. 404. 5104. 5104. 701. 702. 702. 703. 703. 703. 704. 704. 704. 705. 802. 802. 802. 802. 802. 802. 802. 802. 802. 802. 802. 802. 803. 803. 803. 09d 09%e 10a NEW 48-31 48-32 48-33 48-34 48-35 48-36 48-37 48-38 48-39 48-40 48-41 48-42 48-43 48-44 48-45 48-46 48-47 48-48 48-49 48-50 48-51 48-52 48-53 48-54 48-55 48-56 48-57 48-58 48-59 48-60 48-61 48-62 48-63 48-64 48-65 48-66 48-67 48-68 48-69 49-1 49-2 49-3 49-4 49-5 49-6 49-7 49-8 49-9 49-10 49-11 49-12 49-13 49-14 49-15 49-16 49-17 49-18 49-19 49-20 49-21 49-22 49-23 49-24 49-25 49-26 49-27 49-28 49-29 49-30 49-31 49-32 49-32 49-33 49-34 49-35 49-36 49-37 49-38 49-39 49-40 ORIGINAL 803. 803 03b .03c 803. 803. 803. 803. 803. 04 01 .02 03 03d O3e O3f 03g 03h NEW 49-41 49-42 49-43 50-1 50-2 50-3 50-4 50-5 50-6 50-7 50-8 50-9 50-10 S0=11 50-12 50-13 50-14 50-15 50-16 50-17 50-18 50-19 50-20 50-21 31-22 50-23 50-24 50-25 50-26 50-27 50-28 50-29 50-30 50-31 50-32 50-33 50-34 50-35 50-36 50-36 50-36 50-36 50-37 50-36 50-38 50-39 50-40 50-41 50-42 50-43 50-44 50-45 50-46 50-47 50-48 50-49 50-50 50-51 50-52 50-53 50-54 50-55 51-1 51-2 51-3 51-4 51-5 51-6 51-7 51-8 51-9 51-10 Si=11 51-12 51-13 51-14 51-15 51-16 51-17 ORIGINAL 910 910 910 02 .03 04 1002.01a 1002. 1002. 1003. 1003. 1003. 1003. 1003. 1003. 1003. 1003. 1003. 1004. 1004. 1004. Olc 1004. 01d 1004 1004 1004. 1004. 1004. 1004. 1004. 1004. 1005. 1005. 1006. 1106. 1006. 1006. 1006. 1006. 1006. 1006. 1006. 1006. 1006. 1006. 1006. 1006. 1006. 1006. 1006. 1006. 1006. 1006. 1007. 1007. 1007. 1008. 1008. 1008. 1009. 1009. -Ole .O1f 1010.01 1010 1010 1101. 1101. 1101. 1101. .02 -03 1102.03 1102. 1102. 1102. 1102. 1102. 1102. 1102. 1102. 1102. 1102 1102 1102 .02g -02h -02i NEW 51-18 51-19 51-20 51-21 51-22 31=23 51-24 31-25 51-26 51-27 51-28 51-29 51-30 Si=3i 51-32 31=33 51-34 91-35 51-36 31-37 51-38 51-38 51-39 51-40 51-41 51-42 51-43 51-44 51-45 51-46 $1-47 51-48 51-49 51-50 51-51 51-52 51-52 51=52 S1=53 51-54 51-55 51-56 51-57 51-58 51-59 51-60 51-61 51-62 51-63 51-64 51-65 51-66 51-67 51-68 51-69 51-70 $1-71 51-72 S1=73 51-74 51-75 51-76 SIS iii, 51-78 51-79 51-80 51-81 51-82 51-83 51-84 51-85 51-86 51-87 51-88 51-89 51-90 51-91 51-92 51-93 51-94 51-95 ORIGIN AL 1102. 1103. 1103. 1103. 1103. 1103. 1103. 1103. 1103. 1103. 1103. 1103. 1103. 1103. 1103. 1103. 1103. 1103. 1103. 1103. 1101. 1103. 1103. 1103. 1103. 1103. 1103. 1103. 1103. 1103. 1103. 1103. 1108. 1103. 1103. 1102. 1103. 1103. 1103. 1103. 1104. 1104. 1104. 1104. 1104. 1104. 1104. 1104. 1104. 1104. 1105. 1105. 1105. 1105. 1105. 1106. 1106. 1106. 1106. 1106. 1106. 1106. 1106. 1107. 1107. 1107. 1107. 1107. 1107. 1107. 1107. 1107. 1107. 1107. 1107. 1108. 1108. 1108. 02) 28 24 25 O1 NEW 51-96 51-97 51-98 51-99 51-100 51-101 51-102 51-103 51-104 51-105 51-106 51-107 51-108 51-109 51-110 51-111 51-112 51-113 51-114 51-115 51-116 51-117 51-118 51-119 51-120 51-121 51-122 51-123 51-124 51-125 51-126 51-127 51-128 51-129 51-130 51-131 S132 51-133 51-134 52-1 52-2 52-3 52-4 52-5 52-6 52-7 52-8 52-9 52-10 52-11 52-12 52-13 52-14 52-15 52-16 52-17 52-18 52-19 52-20 52-21 52-22 52-23 52-24 52-25 52-26 S221 52-28 52-29 52-30 52-31 52-32 32>33 52-34 52-35 52-36 52-37 52-38 52-39 52-40 52-40 ORIGINAL 1110.05 1108.14 1108.04 1108.21 1108.23 1108.07 1108.08 1108.09 1108.10 1108.05 1108.06 1108.11 1108.12 1108.15 1108.16 1108.17a 1108.20 1108.24 1108.25a 1110.04a 1110.04b 1110.04c 1110.04d 1110.06 1109.01 1109.02 1109.03 1109.07 1109.10 1109.04 1109.05 1109.06 1109.08 1109.09 1110.01 1110.02 1110.03 1110.07 1201.01 1201.02 1201.03 1202.01 1202.02 1203.01a 1203.01b 1203 .01c 1203.01d 1203 .0le 1203 .01f 1204.01a 1204.01b 1204.01c 1204.02 1204.03 1205.01 1205.02 1205 .03c 1205.03b 1206.01 1206.02a 1206.02b 1206.02c 1206.03a 1206.03b 1206.03c 1206.03d 1206.04a 1206.04b 1204.04c 1206.04d 1206.05a 1206.05b 1207.01 1207.02a 1207.02b 1208.01a 1208.01b 1208.01c 1208.01d 52-41 52-42 52-43 52-44 52-45 52-46 53-1 53-2 53-3 53-4 35=5 53-6 33=7 53-8 53-9 53-10 Soe1 53-12 53-13 53-14 53-15 53-16 53-17 53-18 53-19 OF THE UNIVERSITY OF ILLINOIS NEW ORIGINAL 1209. 1210. 1210. 1210. 1210. 1301. 1301. 1301. 1301. 1301. 1301. 1301. 1301. 1301. 1301. 1301. 1302. 1302. 1302. 1302. 1302. 1302. 1302. 1302. 1302. 1302. 1302. 1302. 1302. 1303. 1303. 1302. 1303. 1303. 1303. 1303. 1303. 1303. 1303. 1303. 1303. 1303. 1304. 1304. 1304. 1304. 1304. 1304. 1304. 1305. 1305. 1305. 1305. 1305. 1305. 1305. 1305. 2713058 1305. 1305. 1305. 1305. 1305. 1305. 1305. 1305. 1305. 1305.05 1305. 1305. 1305. 1305. 1305. 1305. 1305. 1305. 1305. 1305. 1305. 01 NEW ORIGINAL SU 53-73 53-74 33515 53-76 53-717 53-78 53-79 53-80 53-81 53-82 53-83 53-84 53-85 53-86 53-87 53-88 53-89 53-90 33-91 53-92 53-93 53-94 53-95 53-96 53-97 53-98 53-99 53-100 53-101 53-102 53-103 53-104 53-105 53-106 53-107 53-108 53-109 53-110 53-111 53-112 Doms) 53-114 53-115 53-116 eed lily/ 53-118 53-119 53-120 53-121 53-122 53-123 53-124 53-125 53-126 53-127 53-128 53-129 53-130 53-131 53-132 53-133 53-134 53-135 53-136 DS=13i 53-138 53-139 53-140 53-141 53-142 53-143 53-144 53-145 53-146 53-147 53-148 53-149 53-150 53-151 53-152 1305. 1305. 1305. 1305. 1305. 1305. 1305. 1305. 1305. 1305. 1305 07g 07h O7i-1 O7i-2 07i-3 07i-4 07i-5 07i-6 O7i-7 07i-8 -07i-9 1305. 1305. 1305. 1305. 1305. 1305. 1305. 1305. 1305. 1305. 1305. 1305. 1305. 1305. 1305. 1305. 1305. 1305. 1305. 1305. 1305. 1305. 1305. 1305. 1305. 1305. 1305. 1305. 1305. 1305. 1305. 1306. 1306. 1306. 1306. 1306. 1306. 1306. 1306. 1306. 1306. 1306. 1306. 1306. 1306. 1307. 1307. 1307. 1307. 1307. 1307. 1307. 1307. 1307. 1307. 07i-10 07j-1 1307.03 1307.0: 1307. 1307. 1307. 1307. 1307. 1307. 1307. 1307. 1307. 1307. 1307.03 1307. 1307. NEW ORIGINAL 53=153 53-154 53-155 53-156 53-157 53-158 53-159 53-160 53-161 53-162 53-163 53-164 53-165 53-166 53-167 53-168 53-169 53-169 53-169 53-170 eo yal 53-172 53-173 53-174 53-175 53-176 53-177 53-178 53-179 53-180 53-181 53-182 53-183 53-184 53-185 53-186 53-187 53-188 53-189 53-190 93=191 53-192 53-193 53-194 93-195 54-1 54-2 54-3 54-4 54-5 54-6 54-7 54-8 54-9 54-10 54-11 54-12 54-13 54-14 54-15 54-15 54-16 54-17 54-18 54-19 54-20 54-21 54-22 54-23 54-24 54-25 54-26 54-27 54-28 54-29 54-30 54-31 54-32 54-33 54-34 1307 .03/-2 1307 .03/-3 1307 .03/-4 1307 .03/-5 1307 .03/-6 1307 .03/-7 1307.03n 1307 .030 1307 .04a 1307 .04b 1307 .04c 1307.05 1307.06 1307.07 1307.08a 1307 .08b 1307 .08c-1 1308. 08c—2 1307 .08c—3 1308. 08c-4 1307.09 1307.10 1307.11 1308.01a&b 1308.02 1309.04 1309.01a 1309 .02a 1309.01b-1 1309 .01b-2 1309 .01b-3 1309.01b-4 1309 .01b-5 1309 .02b 1309.03a 1309.03b 1309 .03c-1 1309 .03c—2 1309 .03c—3 1309 .03e 1309 .03d-1 1309 .03d-2 1309 .03d-3 1401.04 1401.05 1401.02 1401.06 1402.01 1402.02 1402.03 1402.04 1403.01 1403.02 1403.03 1403.04 1401.03 1403.05 1403.07 1404.03 1403.08 1403.09 1403.10 1404.05 1404.06 1404.07 1404.01 1403.06b 1403.06a 1404.02a 1404.02a-1 1404.02a—2 1404.02a-3 1404.02b 1404.04 1405.01 1405.02 1406.01 1406.02a NEW 54-35 54-36 54-37 54-38 54-38 54-39 54-40 54-41 54-42 54-43 54-44 54-45 54-46 54-47 54-48 54-49 54-50 54-51 54-52 54-53 54-54 54-55 54-56 54-57 54-58 54-59 54-60 54-61 54-62 54-63 54-64 54-65 54-66 54-67 54-68 54-69 54-70 54-71 54-72 55-1 Jo-2 5o-3 55-4 55-5 55-6 55-7 55-8 55-9 55-10 Gehl 55-12 Do-13 55-14 55-15 55-15 55-16 Sheet / 55-18 55-19 55-20 Jo—2L 55-22 55-23 55-24 55-25 55-26 Do-2T 55-28 55-29 39-30 59-31 55-32 55-33 55-34 55-35 55-36 55-37 55-38 55-39 55-40 ORIGINAL 1406.02b 1406. 03a&b 1406.03c-1 1406 .03c-2&3 1406.03c—4 1406.07 1406.04a 1406.04b 1406.04c 1406.04d 1406.04e 1406. 04f 1406.04g 1406.05a 1406.05b 1406.05c 1406.05d 1406.05e 1406.05f 1406.05g 1406.05h 1406.06a 1406.06b 1406.08a 1406.08b 1506.03a 1506.03b 1506.03c-1 1506 .03c—2 1506.03c-3 1506.03c—4 1506.03c-5 NEW 55-41 55-42 55-43 55-44 55-45 55-46 55-47 55-48 55-49 55-50 55-51 55-52 39-93 55-54 95 55-56 So-oT 55-58 55-59 55-60 55-61 55-62 55-63 55-64 55-65 55-66 55-67 55-68 55-69 55-70 55-71 55-72 55-73 55-74 9-15 55-76 55-77 55-78 Set) 55-80 55-81 55-82 55-83 55-84 55-85 55-86 55-87 55-88 55-89 55-90 55-91 55-92 55-93 55-94 ORIGINAL 1506.04a 1506.04b 1506.04c 1506.04d 1506.04e 1506.05a 1506.05b 1506.05¢ 1406.05d 1506.05e 1506.05f 1506.05¢g 1506.06 1506.07a 1506.07b 1506.07c 1506.07d 1506.07d-1 1506.07d—2 1506.07d-3 1506.08a 1506.08b 1506.08c 1506 .08d 1506.09a 1506.09b 1506.09c 1506.09d 1506 .09e 1506.09f 1506.10a 1506.10b 1506. 10c 1506.11a 1506.11b 1506. 13a 1506.13b 1506.13b 1506. 13c¢ 1507.01 1507.02 1507.03 1507.04 1508 .01a 1508.01b 1508.02 1508.03 1606.03 1606.04a 1606.04b 1606.04c NEW ORIGINAL 56-24 56-25 56-26 56-27 56-28 56-29 56-30 56-31 56-32 56-33 1606. 1606. 1606. 1607. 1607. 1607. 1608. 1608. 1609. 1610. 1610. 1610. 1701. 1701. 1701. 1701. 1701. 1701. 1701. 1702. 1702. 1703. 1703. 1703. 1703. 1703. 1703. 1704. 1704. 1704. 1704. 1704. 1704. 1704. 1704. 1704. 1704. 1704. 1704. 1704. 1705. 1705. 1706. 1706. 1706. 1706. 1706. 1706. 1706. 1706. 1706. 1706. 1706. 1706. 1706. 1706. 1706. 1706. 1706. 1706. 1706. 1706. 1706. 1706. 1706. 1706. 1706. 1706. 1706. 1706. 1707. 1707. 1707. 1707. 1707. 1707. 1707. 1707. 1707. 1708. NEW ORIGINAL 57-69 57-70 37-71 57-72 57-73 57-74 57-75 57-76 SEU 57-78 57-79 57-80 57-81 57-82 57-83 58-1 58-2 58-3 58-4 58-5 58-5 58-6 58-7 58-8 58-9 58-10 58-11 58-12 58-13 58-14 58-15 58-16 58-17 58-18 58-19 58-20 58-21 58-22 58-23 58-24 58-25 58-26 58-27 58-28 58-29 58-30 58-31 58-32 58-33 58-34 58-35 58-36 58-37 58-38 58-39 58-40 58-41 58-42 58-43 58-44 58-45 58-46 58-47 58-48 58-49 58-50 58-51 58-52 58-53 58-54 58-55 58-56 58-57 58-58 58-59 58-59 58-60 58-61 58-62 58-63 1708.09b 1708.02 1708.03a 1708.03b 1708 .04a 1708.04b 1708.04c 1708.04d 1708.05 1709.01 1710.01 1710.02 1710.03 1710.04 1801.02 1802.01 1802.02a 1802 .02b 1802.03 1802 .04c 1802 .04a 1802 .04b 1802 .04d 1802.05a 1802 .05b 1802.06 1802.07 1802 .07b-1 1802 .07b—2 1802.07c 1802.07d 1802.08 1820.09a 1802.09b 1803.01 1803.02 1803.03a 1803.03b 1803 .03c 1803.03d 1803 .03e 1803 .04b 1803.04a 1803 .04c-1 1803 .04c—2 1803.04d 1803.04e 1803.05 1803.06a 1803 .06b 1804.01 1804.02 1804.03 1804.04 1804.05 1804.06 1805.01 1805.02 1805.03 1805.04 1805.05 1806.01 1806.02 1806.03 1806.04a 1806.04b 1806.04c 1806.04d 1806.05a 1806.05b 1806 .05c 1806.05d 1806 .05e 1807.01 1807.02 1807.03 1807.04 1807.05 1808.01 NEW ORIGINAL NEW ORIGINAL NEW ORIGINAL NEW ORIGINAL 58-64 1808.02a 61-43 2106.02b 64-3 2601.01c 65-4 2701.03b 58-65 1808.02b 61-44 2106.02c 64-4 2601.01d 65-5 2701.03c 58-66 1809.01 61-45 2106.02d 64-5 2601.01d 65-6 2702.05 58-67 1809 .02 61-46 2106.03 64-6 2601.01e 65-7 2702.01 58-68 1809.03a 61-47 2106.04 64-7 2601.03 65-8 2702.02 58-69 1809 .03b 61-48 2106.05 64-8 2601.04 65-9 2702.03 58-70 1809.04 61-49 2106.06 64-9 2601.05 65-10 2702.04a 58-71 1809.05 61-50 2106.07 64-10 2601.06 65-11 2702 .04b 58-72 1809.06 61-51 2106.08 64-11 2601.07 65-12 2702 .04c 58-73 1810.01 61-52 2107.01 64-12 2601.08 65-13 2702.04d 58-74 1810.02 61-53 2107.03 64-13 2601.09 65-14 2702 .04e 58-75 1810.03 61-54 2107.04 64-14 2601.10 65-15 2702 .04£ 58-76 1810.04 61-55 2108.01 64-15 2601.02a&b 65-16 2702 .04g 58-77 1810.05 61-56 2108.02 64-16 2601.02c-1 65-17 2702.04h 58-78 1810.06 61-517 2109.01 64-17 2601.02c-2 65-18 2702.04: 58-79 1811.01 61-58 2109.02 64-18 2601.02c—-3 65-19 2702.04) 58-80 1811.02 61-59 2109.03 64-19 2601.02c—4 65-20 2702.04k 58-81 1811.03 61-60 2110.01a 64-20 2601.02c—5 65-21 2703.01 58-82 1812.01 61-61 2110.01b 64-21 2601.02c—6 65-22 2703.02 58-82 1812.02 61-62 2110.01c 64-22 2601.02d 65-23 2703.03 58-83 1812.04 61-63 2110.01d 64-23 2601.02e 65-24 2703.04 58-84 1812.05 61-64 2110.01e 64-24 2602.01a-1 65-25 2703.05a 58-85 1812.06 61-65 2110.01f 64-25 2602 .01a—2 65-26 2703.05b 58-86 1813.01 61-66 2110.02 64-26 2602.01b-1 65-27 2703.05c 58-87 1813.02a 61-67 2110.03a 64-27 2602 .01b—2 65-28 2703.05d 58-88 1813.02b 61-68 2210.03b-1 64-28 2602 .01b-3 65-29 2703.05e 58-89 1813.02c 61-69 2110.03b—2 64-29 2602 .01b-4 58-90 1813.02d 61-70 2110.03b-3 64-30 2602.01c 66-1 3001.01 61-71 2110.03¢ 64-31 2602.02a 66-2 3001.02 39>! 1901.01 61-72 2110.03d 64-32 2602 .02b 66-3 3001.03 61-73 2111.01a 64-33 2602 .02c¢ 66-4 3001.04 60-1 2001.01 61-74 2111.01b 64-34 2602 .02d 66-5 3001.05a 60-2 2001.02a 61-75 2111.01c 64-35 2602.02e 66-6 3001.05b 60-3 2001.02b 61-76 2111.01id 64-36 2602 .02f 66-7 3001.05c 60-4 2001.03 61-77 2111.0le 64-37 2602.02¢ 66-8 3001.05d 60-5 2002.01 61-78 2112.01 64-38 2602.02h 66-9 3001.05e 61-79 2112.02a 64-39 2602.02i 66-10 3001.06a 61-1 2101.02a 61-80 2112.02b 64-40 2602 .04a 66-11 3001.06b 61-2 2101.02b 61-81 2112.02c 64-41 2602 .04b 66-12 3001 .06c 61-3 2101.02c 61-82 2112.02d 64-42 2602 .04c 66-13 3001.06d 61-4 2101.02d 61-83 2112.02e 64-43 2602.04d 66-14 3001.06e 61-5 2101.03 61-84 2113.01 64-44 2602 .04e 66-15 3001.07a 61-6 2101.04 61-85 2113.02 64-45 2602.04 66-16 3001.07b 61-6 2101.09a 61-86 2113.03 64-46 2602 .04¢ 66-17 3001.07c 61-7 2101.05 61-87 2114.01a 64-47 2602 .04h 66-18 3001.08 61-8 2101.06 61-88 2114.01b 64-48 2602.04; 61-9 2101.07 61-89 2114.02 64-49 2602.04k 67-1 3101.01 61-10 2101.08 61-90 2115.01a 64-50 2602.04] 67-2 3101.02 61-11 2101.09b 61-91 2115.01b 64-S1 2602 .04m 67-3 3101.03 61-12 304.03 61-92 2116.01a 64-52 2603.01 67-4 3102.01 61-12 2101.10 61-93 2116.01b 64-53 2603.02a 67-5 3102 .01c 61-13 2101.12a 61-94 2116.01c 64-54 2603.02b 67-6 3102 .02a 61-14 2101.12b 61-95 2117.01 64-55 2603.02c 67-7 3102 .02b 61-15 2101.12c 61-96 — 64-56 2603.02d 67-8 3102.03a 61-16 2101.12d 61-97 2117.02a 64-57 2603.02e 67-9 3102 .03b 61-17 2102.01 61-98 2117.02b 64-58 2604.01 67-10 3102 .03c 61-18 2102.02a 61-99 2117.02c 64-59 2605.01 67-11 3102.03d 61-19 2102 .02b 61-100 2117.02d 64-60 2605.02 67-12 3102.04a 61-20 2102 .02c 61-101 2118.01a 64-61 2605.03a 67-13 3102 .04b 61-21 2103.01a 61-102 2118.01b 64-62 2605 .03b 67-14 3102.04c 61-22 2103.01b 64-63 2605.03c 67-15 3102 .05a 61-23 2103.01¢ 62-1 2401.01 64-64 2605.03d 67-16 3102.05b 61-24 2103.01d 62-2 2401.02a 64-65 2605.03e 67-17 3102.05c 61-25 2103.02a 62-3 2401.02b 64-66 2605.03f 67-18 3102.06 61-26 2103.02b 62-4 2401.03 64-67 2605.03¢ 67-19 3102.07 61-27 2103 .02c 62-5 2401.04 64-68 2605.03h 67-20 3102.08 61-28 2103.02d 62-6 2402.01 64-69 2605.03i 67-21 3103.01 61-29 2103.02e 62-7 2402 .02a 64-70 2605.03] 67-22 3103.01 61-30 2103 .02f 62-8 2402.02b 64-71 2606.01a 67-23 3103 .02a 61-31 2103.02g 62-9 2402.03 64-72 2606.01b 67-24 3103.02b 61-32 2103.02h 64-73 2606.01c 67-25 3103.03a 61-33 2103 .02i 63-1 2501.01 64-74 2606.01d 67-26 3103.03b 61-34 2104.01 63-2 2501.02 64-75 2606.01e 67-27 3103 .03¢ 61-35 2104.02a 63-3 2501.03 64-76 2606.01f 67-28 3103.03d 61-36 2104.02b 63-4 2501.04 64-77 2607.01a 67-29 3103 .04a 61-37 2104.02c 63-5 2501.05 64-78 2607 .01b 67-30 3103.04b 61-38 2104.03 63-6 2501.06 64-79 2607 .01c 67-31 3103 .04¢ 61-39 2105.01 63=7 2501.07 67-32 3103.05a 61-40 2105.02 65-1 2701.01 67-33 3103.05b 61-41 2106.01 64-1 2601.01a 65-2 2701.02 67-34 3103.05¢ 61-42 2106.02a 64-2 2601.01b 65-3 2701.03a 67-35 3103.06 NEW 67-36 67-37 67-38 67-39 67-40 67-41 67-42 67-43 67-44 67-45 67-46 67-47 67-48 67-49 67-50 67-S1 67-52 67-53 67-54 67-55 67-56 67-57 67-58 67-59 67-60 67-61 67-62 67-63 67-64 67-65 67-66 ORIGINAL 3103 3103 3104 3104 3104 3104 3104. 3104. 3104. .07 .08 .O1 02a -02b -03 NEW 69-12 69-13 69-14 69-15 69-16 69-17 69-18 69-19 69-20 69-21 69=22 69-23 69-24 69-25 69-26 69-27 69-28 69-29 69-30 69-31 70-1 70-2 70-3 70-4 70-5 70-6 70-7 70-8 70-9 70-10 70-11 70-12 70-13 70-14 70-15 70-16 70-17 70-18 70-19 70-20 70-21 70-22 70-23 70-24 7i-1 fiz 71-3 71-4 71-5 71-6 1-7 71-8 71-9 71-10 71-11 11-12 71-13 71-14 71-15 71-16 71-17 71-18 71-19 ORIGINAL 3302. 3302. 3302. 3302. 3302. 3303. 3303. 3303. O3a&b 3303.02 3303. 3303. 3303. 3303. 3304. 3305. 3306. 3306. 3306. 3307. 3307. 3401. 3401. 3401. 3401. 3401. 3401. 3401. 3401. 3461. 3401. 3401. 3401. 3401. 3401. 3401. 3401. 3401. 3401. 3402. 3402. 3402. 3403. 3403. 3403.04 3501. 3501. 3501.0: 3502. 3502. 3502. 3502. 3502. 3502. 3503. 3503. 3503. 3503. 3503. 3508. 3503. 3503. 3503. $503). 3503. 3503. 3503. 3503. 3503. 3503. 3503. 3504. 3504. 3504. 3504. 3504. 3504. 3504. 3504. 3504. NEW 71-36 71-37 71-38 71-39 71-40 71-41 71-42 71-43 71-44 71-45 71-46 71-47 71-48 71-49 71-50 71-51 71-52 71-53 71-54 71-55 71-56 71-57 71-58 72-1 12-2 72-3 72-4 12-5 72-6 72-1 72-8 72-9 72-10 i214 72-12 72-13 72-14 T2=15 72-16 72-17 3-1 73-2 (SS) 73-4 13-5 73-6 13-7 73-8 73-9 73-10 73-11 73-12 73-13 73-14 73-15 73-16 73-17 73-18 73-19 73-20 73-21 73-22 73-23 73-24 73-25 73-26 13-27 73-28 73-29 73-30 73-31 713-32 73-33 73-34 73-35 73-36 13-37 73-38 73-39 ORIGI 3504. 3504. 3501. 3505. 3505. 3505. 3505. 3505. 3505. 3505. 3505. 3505. 3506. 3506. 3506. 3506. 3506. 3506. 3506. 3506. 3506. 3506. 3507. 3601. 3601. 3601. 3601. 3601 3601. 3601. 3601. 3601. 3601. 3601. 3601. 3601. 3601 3601 3601. 3601. 3801. 3802. 3802. 3802. 3802. 3802. 3802. 3802. 3802. 3802. 3802. 3802. 3802. 3802. 3802. 3802. 3802. 3802. 3803. 3803. 3803. 3803. 3803. 3803. 3804. 3804. 3804. 3804. 3804. 3804. 3804. 3804. 3804. 3804. 3804. 3804. 3804. 3804. 3804. NAL 02b O2c&d&e 02f O3a 03b O3c 03d O3e O3f 03g 04a .04b O4c NEW 73-40 73-41 73-42 73-43 73-44 73-45 73-46 73-47 73-48 73-49 73-50 73-51 73-52 73-53 73-54 73-55 73-56 74-1 74-2 74-3 74-4 74-5 74-6 74-7 74-8 74-9 74-10 74-11 74-12 74-13 74-14 74-15 74-16 74-17 74-18 74-19 74-20 74-21 74-22 74-23 74-24 74-25 74-26 74-27 74-28 74-29 74-30 15-1 15-2 75-3 715-4 15-5 75-6 15-7 75-8 75-9 75-10 15-11 75-12 75-13 75-14 75-15 75-16 75-17 75-18 715-19 76-1 76-2 76-3 76-4 76-5 76-6 76-7 76-8 76-9 76-10 76-11 76-12 ORIGINAL 3804.07¢ 3804.07d 3804.08 3805 .01a 3805 .01b 3805 .01c 3801.05d 3805 .01le 3805 .02a 3805 .02b 3805 .02c 3805.03 3805.04 3805.05 3805.06 3805.07 3805.08 3901.01a 3901.01b 3902.01 3902.02 3902.03a 3902.03b 3902.04 3902.05 3902.06 3902.07a 3902.07b 3902.07c 3902.07d 3902.07e 3902.08 3902.09a 3902.09b 3902.09¢ 3902.09d 3902.09e 3902. 09f 3902 .09g-1 3902.09g-2 3902.09h 3902.10a 3902.10b 3902. 11a 3902. 11b 3902.11c 3902. 11d 4001.01a 4001.01b 4002.01 4002.02a 4002.02b 4002 .02c 4002 .02d 4002 .02e 4002. 02f 4002.02 4003.01 4003 .02a 4003 .02b 4003 .02c 4003.02d 4003.02e 4003.03 4003.04 4004.01 4101.01a 4101.01b 4101.01c 4101.02a 4101.02b 4101.02c 4101.02d 4102 .01a 4102.01b 4102.02 4102.03 4102.04a&b NEW ORIGINAL 4102. 4102. 4102. 4102. 4102. 4102. 4102. 4102. 4102. 4102. 4102. 4102. 4102. 4102. 4102. 4102. 4201. 4201. 4201. 4201. 4201. 4201. 4203. 4203. 4203. 4203. 4301. 4301. 4301. 4301. 4301. 4301. 4301. 4301. 4301. 4301. 4301. 4301. 4301. 4301. 4401. 4401. 4410. 4410. 4402. 4402. 4402. 4402. 4402. 4402. 4402. 4402. 4402. 4402. 4402. 4402. 4402. 4402. 4402. 4402. 4402. 4402. 4402. 4402. 4402. 4402. 4402. 4402. 4402. 4402. 4402. 4402. 4402. 4402. 4402. 4403. 4403. 4403. 76-13 76-14 ORIGINAL 4403. 4403. 4403. 4403. 4403. 4403. 4403. 4403. 4403. 4403. 4403. 4403. 4403. 4403. 4403. 4403. 4403. 4403. 4403. 4403. 4403. 4403. 4403. 4403. 4403. 4403, 4403. 4403. 4403. 4403. 4403. 4403. 4403. 4403. 4403. 4403. 4403. 4403. 4403. 4403. 4403. 4403. 4403. 4403. 4403. 4403. 4403. 4403. 4403. 4403. 4403. 4403. 4403. 4403, 4403. 4403. 4403. 4403. 4403. 4403. 4403. 4403. 4403. 44603. 4403. 4403. 4403. 4403. 4403. 4403. 4403. 4403. 4403. 4403. 4403, 4403. 4403. 4403. 4403, 4403. 4404. 02c 03a 03a-1 03a-2 03b NEW 79-120 79-121 79-122 79-123 79-124 79-125 79-126 NOE 79-128 79-129 79-130 79-131 79-132 79-133 79-134 79-135 79-136 79.137 79-138 79-139 79-140 79-141 79-142 79-143 79-144 79-145 79-146 79-147 79-148 79-149 79-150 79-151 79-152 79-153 79-154 79-155 79-156 79-157 79-158 79-159 79-160 79-161 79-162 79-163 79-164 79-165 79-166 79-167 79-168 79-169 79-170 79-171 79-172 79-173 79-174 9-175 79-176 79-177 79-178 79-179 79-180 79-181 79-182 79-183 79-184 79-185 79-186 79-187 79-188 80-1 80-2 80-3 80-4 80-5 80-6 80-7 80-8 80-9 80-10 80-11 ORIGINAL 4405. 4405. 4405. 4405. 4405. 4405. 4405. 4405. 4405. 4405. 4405. 4405. 4405. 4405. 4406. 4406. 4406. 4406. 4406. 4406. 4406. 4406. 4406. 4407. 4407. 4407. 4407. 4407. 4407. 4407. 4407. 4407. 4407. 4408. 4408, 4408. 4408. 4408. 4408. 4408. 4408. 4408. 4408. 4408. 4408. 4408. 4408. 4408. 4408. 4408. 4408. 4408. 4408. 4408. 4408. 4408. 4408. 4408. 4408. 4408. 4408. 4408. 4408. 4409. 4409. 4409. 4409. 4409. 4410. 4601. 4601. 4601. 4604. 4602. 4602. 4602. 1108. 4602. 4603 4603. 01 02 03a 03b O03c 03d 03e NEW 80-12 80-13 80-14 80-15 80-16 80-17 80-18 80-19 80-20 80-21 80-22 80-23 80-24 80-25 80-26 80-27 81-1 81-2 81-2 81-3 81-4 81-5 81-6 81-7 81-8 81-9 81-10 81-11 81-12 81-13 81-14 81-15 81-16 81-17 81-18 81-19 81-20 81-21 81-22 81-23 81-24 81-25 81-26 82-1 82-1 82-2 82-3 82-4 82-5 82-6 82-7 82-8 82-9 82-10 82-11 82-12 82-13 82-14 82-15 82-16 82-17 82-18 82-19 82-20 82-21 82-22 82-23 82-24 82-25 82-26 82-27 82-28 82-29 82-30 82-31 82-32 82-33 82-34 82-35 ORIGINAL 4603.03 4603.04 4605.01 4605.01a 4605.01b 4605.02 4605.03 4605.04 4606.01 4604.02 4606.03 4606.04 4607.01 4608.01 4609.01 4609.02 4701.01a 201.24 4701.01b&c 4701.02 4701.03 4701.64 4702.01 4702.02 4702.03 4702.04 4702.05 4702.06 4702.07a&b 4702.08 4702.09 4703.01 4703.02 4703.03 4703.04 4704.01 4704.02 4704.02 4704.03 4704.04 4704.05 4704.06 4705.01 4801.01 201.23 4801.02 4801.03 4801.04 4801.05 4801.06a&b A4701.16 A4701.17 4801.06c 4810.01 4812.01 4802.01 4802.02 4802 .03a&b 4802 .03c 4802.04 4802.05 4802.06 4802.07 4803.01 4803.02 4803 .03a 4803.03b 4803 .03c 4803 .03d 4803.03e 4803 .03f 4803 .03¢ 4803 .03h 4803.03: 4803 .03j 4803 .03k 4803.04 4803.05 4803.06a NEW 82-36 82-37 82-38 82-39 82-40 82-41 82-42 82-43 82-44 82-45 82-46 82-47 82-48 82-49 82-50 82-51 82-52 82-53 82-54 82-55 82-56 82-57 82-58 82-59 82-60 82-61 82-62 82-63 82-64 82-65 82-66 82-67 82-68 82-69 82-70 82-71 82-72 82-73 82-74 82-75 82-76 82-77 82-78 82-79 82-80 82-81 82-82 82-83 82-84 82-85 82-86 82-87 82-88 82-89 82-90 82-91 82-92 82-93 82-94 82-95 &2-96 82-97 82-98 82-99 82-100 82-101 82-102 82-103 82-104 82-105 82-106 82-107 82-108 82-109 82-110 82-111 82-112 82-113 82-114 82-115 ORIGINAL 4803 .06b 4803 .06c 4803.07 4803 .08a 4803 .08b 4803.09 4803.10 4804.01a 4804.01b 4804. 01c 4804.02 4804.03 4804 .04a 4804.04b 4804.05 4804.06a 4804.06b 4804 .06c 4804.06d 4804.07a 4804.07b 4804.07¢ 4804.08 4804.09 4804.10 4805 .01a 4805 .01b 4805 .02a 4805.02b 4805 .02c 4805.03 4805.04 4805.05 4806.01 4806.02 4806.03 4806 .04a 4806.04b 4806.05 4806.06 4806.07 4806.08a 4806 .08b 4806.09 4806.10 4806.11 4806.12 4806.13 4806.14 4806.15 4806.16 4806.17 4806.18 4806.19 4806.20 4806.21 4806.22 4806.23 4806.24 4807.01 4807 .02 4807.03 4807 .04 4807.05 4807 .06 4807.07 4807.08 4807.09 4807.10 4807.11 4807.12 4807.13 4807.14 4807.15 4807.16 4808.01 4808.02 4808.03 4808.04 4808.05 NEW 82-116 82-117 82-118 82-119 82-120 48-121 48-122 48-123 48-124 48-125 48-126 48-127 48-128 48-129 48-130 48-131 48-132 48-133 48-134 48-135 48-136 48-137 82-138 82-139 82-140 82-141 82-142 82-143 82-144 82-145 82-146 82-147 82-148 82-149 82-150 82-151 82-152 82-153 83-1 83-2 83-3 83-4 83-5 83-6 83-7 83-8 83-9 83-10 83-11 83-12 83-13 83-14 83-15 83-16 83-17 83-18 83-19 83-20 83-21 83=22 83-22 So—25 83-24 83-25 83-26 83-27 83-28 83-29 83-30 83-31 83-32 83-33 83-34 83-35 83-36 83-37 83-38 83-39 83-40 ORIGINAL 4808. 4808. 4808. 4808. 4808. 4808. 4808. 4808. 4808. 4808. 4808. 4808. 4808. 4809. 4809. 4809. 4809. 4809. 4809. 4809. 4809. 4809. 4809. 4809. 4809. 4809. 4809. 4809. 4809. 4809. 4809. 4809. 4811. 4811. 4811. 4811. 4811. 4802. 4901. 4901. 4901. 4901. 4901. 4901. 4901. 4901. 4901. 4901. 4901. 4901. 4901. 4901. 4901. 4901. 4901. 4901. 4901. 4901. 4901. 4901. 4901. 4901. 4901. 4901. 4901. 4901. 4901. 4901. 4901. 4901. 4901. 4901. 4901. 4901. 4901. 4901. 4901. 4901. 4901. NEW ORIGINAL 83-41 83-42 83-43 83444 83-45 83-46 83-47 83-48 83-49 83-50 83-51 83-52 83-53 83-54 83-55 83-56 83-57 83-58 83-58 83-59 83-60 83-61 83-62 83-63 83-64 83-65 83-66 83-67 83-68 83-69 83-70 84-1 84-1 84-2 84-3 84-4 84-5 84-5 84-6 - 84-7 84-8 84-9 84-10 85-1 85-7 85-3 85-4 85-5 85-6 85-7 85-8 85-9 85-10 85-11 85-12 85-13 85-14 85-15 85-16 85-17 85-18 85-19 85-20 85-21 85-22 85-23 85-24 85-25 85-26 85-27 85-28 85-29 85-30 85-31 85-32 85-33 85-34 85-35 4901. 4901. 4901. 4901. 4901. 4901. 4901. 4901. 4901. 4901. 4901. 4901. 4901. 4901. 4901. 4901. 4901. 4901. 4901. 4901. 4901. 4901. 4902. 4901. 4901. 4901. 4901. 4901. 4901. 4901. 4901. 5101. 5201. 5201. 5202. 5203. 5102. 5102. 5102. 5102. 5101. 5102. 5102. 5101. 5301. 5306. 5303. 5305. 5305. 5302. 5302. 5303. 5303. 5303. 5303. 5303. 5303. 5303. 5303. 5303. 5303. 5303. 5303. 5303. 5303. 5303. 5303. 5303.0: 5303. 5303. 5303. 5303. 5303. 5303. 5303. 5303. 5303. $303. ORIGINAL 5303. 5303. 5303. 5303. 5303. 5303. 5303. 5303. 5303. 5303. 5303. 5303. 5303. 5303. 5303. 5303. 5304. 5304. 5304. 5304. 5304. 5304. 5304. 5304. 5304. 5304. 5304. 5304. 5304. 5304. 5304. 5304. 5304. 5304. 5304. 5304. 5102. 5305. 5305. 5102. 5101. 5102. 5102. 5102. 5102. 201. 5401. 5402. 5401. 5402. 5402. 1103. 404. 1103. 05a O05b O5c 05d >. ie is vy =*t a acl i e J ae, I = is od y 2. i : 5) = ' ci i Pe ‘ 4 7 == t Pi ib - { PS 7 f i Ais a vevile: Wit 4 ae Yi 7 \ ‘ve on val | a wn 5 wr ) : eae i te re Me he jf fk. aif Pibas : f a A \ r) i j rl Ny j Wi ahi ee Bei dine A |e pire iy ih Dee es ek os ee Dd — VERSITY OF ILLINOIS Png on ve See oe PER: see